Notice of Retraction Passive Islanding Detection Method for Grid Connected PV System

Passive islanding detection method is an important concern for grid connected photovoltaic (PV) power generation system due to personnel and equipment safety. Over/Under Voltage Protection (OVP/UVP) and Over/Under Frequency Protection (OFP/UFP) are basical inverter resident passive islanding detection method (IDM) for detecting an islanding condition by monitor parameters in point of common coupling (PCC) such as voltage amplitude and frequency and then cause the inverter to shut down when there is sufficient transition from normal specified conditions. The real and reactive power equations and Non-Detection Zone (NDZ) of OVP/UVP and OFP/UFP methods for grid connected PV system are derived and analyzed in this paper. Analyses show that the behavior of the system at the time of disconnection will depend on the imbalance power at the instant before the switch opens to form the island, these results also indicate the NDZ of OVP/UVP and OFP/UFP methods is considerable large and the reaction times for these protective methodologies may be variable or unpredictable.

[1]  Ajeet Rohatgi,et al.  Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones , 2000 .

[2]  S. Gonzalez,et al.  Development of a MATLAB/Simulink Model of a Single-Phase Grid-Connected Photovoltaic System , 2009, IEEE Transactions on Energy Conversion.

[3]  Ajeet Rohatgi,et al.  Prevention of islanding in grid‐connected photovoltaic systems , 1999 .

[4]  Michael Eugene Ropp Design issues for grid-connected photovoltaic systems , 1998 .

[5]  Kwang-Ho Kim,et al.  An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current , 2004 .

[6]  Huili Sun Performance assessment of islanding detection methods using the concept of non-detection zones , 2005 .

[7]  V. P. Sundarsingh,et al.  Novel grid-connected photovoltaic inverter , 1996 .

[8]  A. Kitamura,et al.  Islanding phenomenon elimination study at Rokko test center , 1994, Proceedings of 1994 IEEE 1st World Conference on Photovoltaic Energy Conversion - WCPEC (A Joint Conference of PVSC, PVSEC and PSEC).

[9]  Ronnie Belmans,et al.  Testing the islanding protection function of photovoltaic inverters , 2003 .

[10]  G. Kern SunSine300, utility interactive AC module anti-islanding test results , 1997, Conference Record of the Twenty Sixth IEEE Photovoltaic Specialists Conference - 1997.

[11]  Chern-Lin Chen,et al.  Automatic phase-shift method for islanding detection of grid-connected photovoltaic inverters , 2002 .

[12]  Yu Zhang,et al.  Evaluation of anti-islanding schemes based on nondetection zone concept , 2004, IEEE Transactions on Power Electronics.