Improved Real-Time Capability for Nonlinear Seperable Harmonic Filtering of Ultrasound Images Using a Damped Regularization Method With In-Vivo Results

During the early stage of the disease, idiopathic Parkinson’s Disease can be very difficult to differentiate from atypical parkinsonian syndromes. Hyperechogenicity in the substantia nigra is one marker that has been shown to help make this differential diagnosis, and Transcranial Ultrasound Imaging is the preferred method for detecting SN hyperechogenicity. Hyperechogenicity is defined as an echogenic area larger than 0.2cm2. However, B-mode imaging often contains enough noise that the boundary may not be clear, thus making this diagnosis much more difficult. Harmonic imaging using a Third- Order Volterra filter is one solution that has been shown to be successful in filtering out the noise in these images. In this paper we show that regularization methods such as the Truncated Singular Value Decomposi- tion and Damped Singular Value Decomposition can be used to solve for the Volterra Filter’s coefficients much more quickly than adaptive Least Mean Squared methods without sacrifice in image quality. These findings have significant implications for the viability of using the Volterra Filter in real-time applications.

[1]  Pornchai Phukpattaranont,et al.  Separation of Nonlinear Ultrasound Signals Based on Second-Order Volterra System Identification , 2009 .

[2]  Matthias Reimold,et al.  The specificity and sensitivity of transcranial ultrasound in the differential diagnosis of Parkinson's disease: a prospective blinded study , 2008, The Lancet Neurology.

[3]  E.S. Ebbini,et al.  Post-beamforming second-order Volterra filter for pulse-echo ultrasonic imaging , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Mohamed Almekkawy,et al.  Transcranial enhanced Ultrasound Imaging of induced substantia nigra in brain using adaptive Third Order Volterra Filter: In-vivo results , 2017, 2017 IEEE 14th International Symposium on Biomedical Imaging (ISBI 2017).

[5]  Uwe Walter,et al.  Transcranial sonography in movement disorders , 2008, The Lancet Neurology.

[6]  Thyagarajan Subramanian,et al.  Detection of MPTP-induced substantia nigra hyperechogenicity in Rhesus monkeys by transcranial ultrasound. , 2010, Ultrasound in medicine & biology.

[7]  Pornchai Phukpattaranont,et al.  Design of a quadratic filter for contrast - assisted ultrasonic imaging based on 2D gaussian filters , 2010 .

[8]  Yi Song,et al.  In-vivo transcranial ultrasound imaging of induced Substantia Nigra hyperechogenicity using adaptive sparse Third Order Volterra Filter , 2017, 2017 8th International IEEE/EMBS Conference on Neural Engineering (NER).

[9]  Yi Zheng,et al.  Regularization methods for solving third-order volterra filter with improved convergence speed: In-vivo application , 2018, 2018 IEEE 15th International Symposium on Biomedical Imaging (ISBI 2018).

[10]  Daniela Berg,et al.  Hyperechogenicity of the substantia nigra: pitfalls in assessment and specificity for Parkinson’s disease , 2011, Journal of Neural Transmission.

[11]  Pornchai Phukpattaranont,et al.  Detection and mapping of thermal lesions using dual-mode ultrasound phased arrays , 2002, 2002 IEEE Ultrasonics Symposium, 2002. Proceedings..

[12]  John C. Bischof,et al.  QUADRATIC B-MODE AND PULSE INVERSION IMAGING OF THERMALLY-INDUCED LESIONS IN VIVO , 2007, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[13]  M. Ekstrom,et al.  On the Application of Eigenvector Expansions to Numerical Deconvolution , 1974 .

[14]  Emad S. Ebbini,et al.  Nonlinear Imaging of Microbubble Contrast Agent Using the Volterra Filter: In Vivo Results , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.