Elimination of ECG Artifacts from Myoelectric Prosthesis Control Signals Developed by Targeted Muscle Reinnervation

We investigated elimination of electrocardiogram (ECG) artifacts from the myoelectric prosthesis control signals, taken from the reinnervated pectoralis muscles of a patient with bilateral amputations at shoulder disarticulation level. The performance of various ECG artifact removal methods including high pass filtering, spike clipping, template subtracting, wavelet thresholding and adaptive filtering was presented. In particular, considering the clinical requirements and memory limitation of commercial prosthesis controllers, we further explored suitable means of ECG artifact removal for clinical application

[1]  C Marque,et al.  Adaptive filtering for ECG rejection from surface EMG recordings. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[2]  Werner Wolf,et al.  New aspects to event-synchronous cancellation of ECG interference: an application of the method in diaphragmatic EMG signals , 2000, IEEE Transactions on Biomedical Engineering.

[3]  R Bloch Subtraction of electrocardiographic signal from respiratory electromyogram. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[4]  P. Strobach,et al.  Event-synchronous cancellation of the heart interference in biomedical signals , 1994, IEEE Transactions on Biomedical Engineering.

[5]  A. Bartolo,et al.  Description and validation of a technique for the removal of ECG contamination from diaphragmatic EMG signal , 2007, Medical and Biological Engineering and Computing.

[6]  Ravinder K. Mittal,et al.  Adaptive cancellation of ECG artifacts in the diaphragm electromyographic signals obtained through intraoesophageal electrodes during swallowing and inspiration , 1994 .

[7]  P. Akkiraju,et al.  Adaptive cancellation technique in processing myoelectric activity of respiratory muscles , 1992, IEEE Transactions on Biomedical Engineering.

[8]  Robert D. Lipschutz,et al.  The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee , 2004, Prosthetics and orthotics international.

[9]  E. Kwatny,et al.  Description and validation of an ECG removal procedure for EMGdi power spectrum analysis. , 1986, Journal of applied physiology.

[10]  D Chaffin,et al.  High-pass filtering to remove electrocardiographic interference from torso EMG recordings. , 1993, Clinical biomechanics.

[11]  B. Widrow,et al.  Adaptive noise cancelling: Principles and applications , 1975 .

[12]  A Bartolo,et al.  Analysis of diaphragm EMG signals: comparison of gating vs. subtraction for removal of ECG contamination. , 1996, Journal of applied physiology.