Improved Tracking and Switching Performance of an Electro-Pneumatic Positioning System

For robotic systems that use on/off (solenoid) pneumatic actuators, a sliding mode control law for precise position control and low switching (open-close) activity of the valves is presented in this paper. Given a pneumatic actuator with two chambers and four solenoid valves, there are sixteen possible input combinations defined directly from the state of the four on/off valves present in the system; however, only seven of these discrete operating modes are considered both functional and unique. Therefore, we introduce a novel seven-mode sliding controller that minimizes the position tracking error using modes that have both the necessary and sufficient amounts of drive energy and, thus, involve reduced switching activity. An analysis of the closed-loop system stability is carried out. The performance of the proposed control design is experimentally verified on a single pneumatic actuator setup comprising of two chambers with four on/off valves.

[1]  J. Leavitt,et al.  Accurate Sliding-Mode Control of Pneumatic Systems Using Low-Cost Solenoid Valves , 2007, IEEE/ASME Transactions on Mechatronics.

[2]  Mahdi Tavakoli,et al.  Sliding mode control of a pneumatic haptic teleoperation system with on/off solenoid valves , 2011, 2011 IEEE International Conference on Robotics and Automation.

[3]  Jens Frahm,et al.  Real‐time MRI at a resolution of 20 ms , 2010, NMR in biomedicine.

[4]  Franck Plestan,et al.  High-Order Sliding-Mode Controllers of an Electropneumatic Actuator: Application to an Aeronautic Benchmark , 2009, IEEE Transactions on Control Systems Technology.

[5]  Essa Yacoub,et al.  Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast. , 2004, Journal of biomechanical engineering.

[6]  Jun Wu,et al.  Tracking control of pneumatic artificial muscle actuators based on sliding mode and non-linear disturbance observer , 2010 .

[7]  M. Bock,et al.  An MRI-Compatible Surgical Robot for Precise Radiological Interventions , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[8]  Ming-Chang Shih,et al.  Position control of a pneumatic cylinder using fuzzy PWM control method , 1998 .

[9]  R. Riener,et al.  Comparison of MRI-Compatible Mechatronic Systems With Hydrodynamic and Pneumatic Actuation , 2008, IEEE/ASME Transactions on Mechatronics.

[10]  Jianlong Zhang,et al.  Nonlinear Model-Based Control of Pulse Width Modulated Pneumatic Servo Systems , 2006 .

[11]  Tanneguy Redarce,et al.  Transparency of a pneumatic teleoperation system using on/off solenoid valves , 2010, 19th International Symposium in Robot and Human Interactive Communication.

[12]  Franck Plestan,et al.  Higher order sliding mode control based on optimal approach of an electropneumatic actuator , 2006 .

[13]  Nicola Ivan Giannoccaro,et al.  Experimenting and modelling the dynamics of pneumatic actuators controlled by the pulse width modulation (PWM) technique , 2005 .

[14]  Kyoung Kwan Ahn,et al.  Intelligent switching control of pneumatic actuator using on/off solenoid valves , 2005 .

[15]  Ali Ghaffari,et al.  Improving dynamic performances of PWM-driven servo-pneumatic systems via a novel pneumatic circuit. , 2009, ISA transactions.

[16]  M.G. Fujie,et al.  Development of MRI Compatible Versatile Manipulator for Minimally Invasive Surgery , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[17]  Gi Sang Choi,et al.  A study on tracking position control of pneumatic actuators , 2002 .

[18]  Hao-Chi Chang,et al.  Sliding mode control on electro-mechanical systems , 1999 .

[19]  Peter Beater,et al.  Pneumatic Drives: System Design, Modelling and Control , 2007 .

[20]  J.A. Rosas-Flores,et al.  Optimal linearization of the dynamic behavior of an on/off actuated single pneumatic cylinder , 2008, 2008 5th International Conference on Electrical Engineering, Computing Science and Automatic Control.

[21]  Ming Li,et al.  Robotic System for Transapical Aortic Valve Replacement with MRI Guidance , 2008, MICCAI.

[22]  Vadim I. Utkin,et al.  Sliding mode control design principles and applications to electric drives , 1993, IEEE Trans. Ind. Electron..