Magnetic plethysmograph transducers for local blood pulse wave velocity measurement

We present the design of magnetic plethysmograph (MPG) transducers for detection of blood pulse waveform and evaluation of local pulse wave velocity (PWV), for potential use in cuffless blood pressure (BP) monitoring. The sensors utilize a Hall effect magnetic field sensor to capture the blood pulse waveform. A strap based design is performed to enable reliable capture of large number of cardiac cycles with relative ease. The ability of the transducer to consistently detect the blood pulse is verified by in-vivo trials on few volunteers. A duality of such transducers is utilized to capture the local PWV at the carotid artery. The pulse transit time (PTT) between the two detected pulse waveforms, measured along a small section of the carotid artery, was evaluated using automated algorithms to ensure consistency of measurements. The correlation between the measured values of local PWV and BP was also investigated. The developed transducers provide a reliable, easy modality for detecting pulse waveform on superficial arteries. Such transducers, used for measurement of local PWV, could potentially be utilized for cuffless, continuous evaluation of BP at various superficial arterial sites.

[1]  Chin-Shan Ho,et al.  A novel method for measurement of pulse wave velocity by dual-channel photoplethysmography , 2004, IEEE International Workshop on Biomedical Circuits and Systems, 2004..

[2]  D. Fei,et al.  Rapid aortic wave velocity measurement with MR imaging. , 2001, Radiology.

[3]  J. Carroll,et al.  Determination of pulse wave velocities with computerized algorithms. , 1991, American heart journal.

[4]  S Kontis,et al.  On-line Doppler ultrasound measurement of aortic compliance and its repeatability in normal subjects. , 1989, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[5]  B. Pannier,et al.  Assessment of arterial distensibility by automatic pulse wave velocity measurement. Validation and clinical application studies. , 1995, Hypertension.

[6]  Robert D. Boehmer,et al.  Continuous, Real-Time, Noninvasive Monitor of Blood Pressure: Peňaz Methodology Applied to the Finger , 1987, Journal of Clinical Monitoring.

[7]  H. Struijker‐Boudier,et al.  Expert consensus document on arterial stiffness: methodological issues and clinical applications. , 2006, European heart journal.

[8]  Kejia Li,et al.  Initial study on pulse wave velocity acquired from one hand using two synchronized wireless reflectance pulse oximeters , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.