Development of an EUV polarimeter with a transmission multilayer

We developed an EUV polarimeter consisting of a transmission multilayer and a back-illumination CCD. The transmission of the multilayer at an incident angle of45-deg depends on the polarization angle. We developed a polarimeter by using the transmission. Advantages of usage a transmission multilayer are as follows. 1) The mechanics is simple, because we do not need to move the detectors. 2) High energy photons, where the multilayer is transparent, can be measured as a normal observation, if we use a CCD as a photon counting. 3) By removing the multilayer from the optical axis, normal observation with a CCD can be performed. A stand alone multilayer of Mo/Si was fabricated, which consists of seven layer-pairs with a thickness of 20 nm. We evaluated the performance of the polarimeter using a synchrotron beam line. We confirmed a modulation factor of 47% around 95 eV.

[1]  Yoshitomo Maeda,et al.  X-ray polarimeter with a multilayer-coated CCD , 2006, SPIE Astronomical Telescopes + Instrumentation.

[2]  Masaki Yamamoto Polarimetry with use of soft x-ray multilayers , 1994, Optics & Photonics.

[3]  Kazuo Makishima,et al.  Fine-pitch and thick-foil gas electron multipliers for cosmic x-ray polarimeters , 2006, SPIE Astronomical Telescopes + Instrumentation.

[4]  Naohisa Anabuki,et al.  Observation of Crab Nebula with hard x-ray polarimeter: PHENEX , 2007, SPIE Optical Engineering + Applications.

[5]  H. W. Schnopper,et al.  POLARIMETER FOR CELESTIAL X RAYS. , 1969 .

[6]  Ronaldo Bellazzini,et al.  The gas pixel detector as an x-ray photoelectric polarimeter with a large field of view , 2008, Astronomical Telescopes + Instrumentation.

[7]  Kazuo Makishima,et al.  Development of cosmic x-ray polarimeter , 2006, SPIE Astronomical Telescopes + Instrumentation.

[8]  Luca Baldini,et al.  X-ray polarimetry on-board of HXMT , 2008, Astronomical Telescopes + Instrumentation.

[9]  M. C. Weisskopf,et al.  A Graphite Crystal Polarimeter for Stellar X‐Ray Astronomy , 1972 .

[10]  Keisuke Tamura,et al.  Application of a charge-coupled device as an x-ray polarimeter , 1994, Optics & Photonics.

[11]  K. Long,et al.  A precision measurement of the X-ray polarization of the Crab Nebula without pulsar contamination. , 1978 .

[12]  Martin C. Weisskopf,et al.  Detection of X-Ray Polarization of the Crab Nebula , 1972 .

[13]  Klaus H. Schmidt,et al.  Hard x-ray polarimetry exploiting directional information of the photoeffect in a charge coupled device , 1998, Optics & Photonics.

[14]  Shunji Kitamoto,et al.  Adaptive x-ray optics with a deformable mirror , 2005, SPIE Optics + Photonics.

[15]  Shigeru Morita,et al.  Apparatus for characterizing the VUV and soft x‐ray optical elements at the Photon Factory , 1989 .