Multipoint mapping for imaging of semi-solid materials.

Multipoint k-space mapping is a hybrid between constant-time (single-point mapping) and spin-warp imaging, involving sampling of a k-line segment of r points per TR cycle. In this work the method was implemented for NMR imaging of semi-solid materials on a 400 MHz micro-imaging system and two different k-space sampling strategies were investigated to minimize the adverse effects from relaxation-induced k-space signal modulation. Signal attenuation from T(2) decay results in artifacts whose nature depends on the k-space sampling strategy. The artifacts can be minimized by increasing the readout gradient amplitude, by PSF deconvolution or by oversampling in readout direction. Finally, implementation of a T(2) selective RF excitation demonstrates the feasibility of obtaining short-T(2) contrast even in the presence of tissues with long-T(2). The method's potential is illustrated with 3D proton images of short-T(2) materials such as synthetic polymers and bone.

[1]  J. Pauly,et al.  Supression of long-T2 components for short T2 imaging , 1992 .

[2]  S. Emid,et al.  High resolution NMR imaging in solids , 1985 .

[3]  D. Cory,et al.  Sensitivity and Resolution of Constant-Time Imaging , 1994 .

[4]  K Oshio,et al.  A computer simulation of T2 decay effects in echo planar imaging , 1989, Magnetic resonance in medicine.

[5]  C F Beaulieu,et al.  MR imaging of articular cartilage of the knee: new methods using ultrashort TEs. , 1998, AJR. American journal of roentgenology.

[6]  D. Hoepfel,et al.  Application of single point imaging (SPI) to solid state materials. , 2001, Magnetic resonance imaging.

[7]  L P Panych,et al.  Comparing the FAISE method with conventional dual‐echo sequences , 1991, Journal of magnetic resonance imaging : JMRI.

[8]  T W Bremner,et al.  The influence of shrinkage-cracking on the drying behaviour of White Portland cement using Single-Point Imaging (SPI). , 1998, Solid state nuclear magnetic resonance.

[9]  F. Schick Bone marrow NMR in vivo , 1996 .

[10]  T W Bremner,et al.  Imaging of heterogeneous materials with a turbo spin echo single-point imaging technique. , 2000, Journal of magnetic resonance.

[11]  J M Pauly,et al.  Design of practical T2‐selective RF excitation (TELEX) pulses , 1998, Magnetic resonance in medicine.

[12]  D. Axelson,et al.  H magnetic resonance imaging of rigid polymeric solids. , 1996, Solid state nuclear magnetic resonance.

[13]  Y M Ro,et al.  Multipoint K‐space point mapping (KPM) technique for NMR microscopy , 1994, Magnetic resonance in medicine.

[14]  A. MacKay,et al.  In vivo visualization of myelin water in brain by magnetic resonance , 1994, Magnetic resonance in medicine.

[15]  Felix W Wehrli,et al.  Diffusion of exchangeable water in cortical bone studied by nuclear magnetic resonance. , 2002, Biophysical journal.

[16]  SPARE: A robust method for magnetic resonance imaging in inhomogeneous fields. , 1998, Journal of magnetic resonance.