A Fully Automatic Press for Mechanical and Electrical Testing of Full-Size ITER Conductors under Transverse Cyclic Load

A cryogenic cable press has been built and recently modified to investigate the life time properties and changes in the mechanical and electrical properties of full‐size ITER (International Thermonuclear Experimental Reactor) conductors. The press is a fully automatically controlled operating system designed to test Cable‐In‐Conduit Conductors (CICC) under transverse variable load along 40,000 cycles at temperatures from 4.2 to 300 K. The designed lifetime of the press, with moving parts and minimized friction at cryogenic temperatures, is at least a few millions of cycles. The maximum press load is 320 kN with a stroke of 5.5 mm. The maximum sample length amounts to 400 mm. The force on the cable and the compression are monitored simultaneously in order to determine the mechanical cable deformation properties and losses. A superconducting dipole coil integrated in the press surrounding the sample, provides the DC and AC magnetic field required to perform magnetization measurements with pick‐up coils. In ...

[1]  A. Nijhuis,et al.  Performance of an ITER CS1 model coil conductor under transverse cyclic loading up to 40,000 cycles , 2004, IEEE Transactions on Applied Superconductivity.

[2]  H. Kate,et al.  A Novel “Test Arrangement for Strain Influence on Strands” (TARSIS): Mechanical and Electrical Testing of ITER Nb3Sn Strands , 2004 .

[3]  Arend Nijhuis,et al.  Change of interstrand contact resistance and coupling loss in various prototype ITER NbTi conductors with transverse loading in the Twente Cryogenic Cable Press up to 40,000 cycles , 2004 .

[4]  P. Bruzzone,et al.  Parametric studies of subsize NbTi cable-in-conduit superconductors for ITER-FEAT , 2003 .

[5]  H. Kate,et al.  Evolution of Contact Resistance and Coupling Loss of ITER PF Prototype Conductors under Transverse Cyclic Load , 2002 .

[6]  N. Mitchell,et al.  Electromagnetic and mechanical AC loss of an ITER TF model coil conductor (DP4) under transverse cyclic loading , 2000, IEEE Transactions on Applied Superconductivity.

[7]  N. Mitchell,et al.  Electromagnetic and mechanical characterisation of ITER CS-MC conductors affected by transverse cyclic loading. I. Coupling current loss , 1999, IEEE Transactions on Applied Superconductivity.

[8]  N. Mitchell,et al.  Electromagnetic and mechanical characterisation of ITER CS-MC conductors affected by transverse cyclic loading. III. Mechanical properties , 1999, IEEE Transactions on Applied Superconductivity.

[9]  N. Mitchell,et al.  Electromagnetic and mechanical characterisation of ITER CS-MC conductors affected by transverse cyclic loading. II. Interstrand contact resistances , 1999, IEEE Transactions on Applied Superconductivity.