MICRA: A Compact Permanent Magnet Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

MICRA,1 a compact Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer is described. The amount of miniaturisation in this device, based on a 1.24 T permanent magnet, remains compatible with genuine FT-ICR performance and analytical power in the mass range 2–1000 m/z, with a mass resolving power of 73,000 at mass 132. A first application of the transportability is the repetitive coupling of MICRA with a large-scale source of IR photons, the free electron laser CLIO.

[1]  A. J. Peurrung,et al.  Analysis of space-charge effects in cyclotron resonance mass spectrometry as coupled gyrator phenomena , 1995 .

[2]  A. Simon,et al.  Ultrasensitive spectroscopy of ionic reactive intermediates in the gas phase performed with the first coupling of an IR FEL with an FTICR-MS , 2003 .

[3]  A. Marshall Milestones in fourier transform ion cyclotron resonance mass spectrometry technique development , 2000 .

[4]  G. Meijer,et al.  Infrared Spectroscopy of Jet-cooled Cationic Polyaromatic Hydrocarbons: Naphthalene+ , 1999 .

[5]  Joseph E. Campana,et al.  Characterization of a small FTICR mass spectrometer based on a permanent magnet , 1993 .

[6]  H. Kenttämaa,et al.  Characterization of long-chain carboxylic esters with CH3OBOCH3+ in a small fourier-transform ion cyclotron resonance mass spectrometer , 1996, Journal of the American Society for Mass Spectrometry.

[7]  M. Crestoni,et al.  Infrared fingerprint of protonated benzene in the gas phase. , 2003, Angewandte Chemie.

[8]  D. Dahl simion for the personal computer in reflection , 2000 .

[9]  Richard D. Smith,et al.  Prediction of a space charge induced upper molecular mass limit towards achieving unit mass resolution in Fourier transform ion cyclotron resonance mass spectrometry , 1996 .

[10]  P. Pernot,et al.  Successive reactions of iron carbonyl cations with dimethyl ether: direct cleavage versus rearrangement , 2002 .

[11]  M. Nyman,et al.  Determination of 3,3′-Dichlorobenzidine and its degradation products in environmental samples with a small low-field Fourier transform ion cyclotron resonance mass spectrometer , 1999, Journal of the American Society for Mass Spectrometry.

[12]  J. Hipple,et al.  THE MEASUREMENT OF e/M BY CYCLOTRON RESONANCE , 1951 .

[13]  J. Coey Permanent magnet applications , 2002 .

[14]  V. Anicich Evaluated Bimolecular Ion‐Molecule Gas Phase Kinetics of Positive Ions for Use in Modeling Planetary Atmospheres, Cometary Comae, and Interstellar Clouds , 1993 .

[15]  H. Kenttämaa,et al.  Differentiation of stereoisomeric diols by using CH3OB+OCH3 in a small Fourier transform ion cyclotron resonance mass spectrometer , 1995 .