The response comparison of a hydrogen-bond acidic polymer to sarin, soman and dimethyl methyl phosphonate based on a surface acoustic wave sensor

A hydrogen-bond acidic (HBA) polymer, poly{methyl[3-(2-hydroxyl, 4,6-bistrifluoromethyl)phenyl]propylsiloxane}(DKAP), was coated on a 434 MHz surface acoustic wave (SAW) device, and subsequently tested against sarin (GB) and soman (GD) vapour along with dimethyl methyl phosphonate (DMMP) at concentrations below 10 mg m−3. The direct detection of GB and GD in the sub mg m−3 range, indicated the high sensitivity of the sensor, and was demonstrated by the corresponding sensor which showed high reproducibility as well. However, the response of the sensor to the real agents was relatively smaller and slower than to the simulant DMMP. Towards the real agents, the time to reach an adsorption equilibrium was considerable (∼16 min) and a time-dependent linear response was observed in the initial >3 min for both the adsorption and the desorption processes. The sensor was also compared with other HBA polymers coated SAW sensors in terms of response characteristics, with emphasis on the kinetic response behaviour. The slow adsorption and desorption property of the DKAP sensor towards the real chemical agents was attributed to the effect of the size of the analytes and to the strength of hydrogen-bonding, respectively.

[1]  M. Roukes,et al.  Nanoelectromechanical resonator arrays for ultrafast, gas-phase chromatographic chemical analysis. , 2010, Nano letters.

[2]  Mamta Khaneja,et al.  Development of handheld SAW vapor sensors for explosives and CW agents , 2009 .

[3]  Herbert H Hill,et al.  Detection of a chemical warfare agent simulant in various aerosol matrixes by ion mobility time-of-flight mass spectrometry. , 2005, Analytical chemistry.

[4]  Duk-Dong Lee,et al.  Fabrication of polymer SAW sensor array to classify chemical warfare agents , 2007 .

[5]  D. Dubey,et al.  Application of single drop microextraction for analysis of chemical warfare agents and related compounds in water by gas chromatography/mass spectrometry. , 2005, Analytical chemistry.

[6]  Yang Wang,et al.  A simple route to functionalize siloxane polymers for DMMP sensing , 2013 .

[7]  Kwan Kyu Park,et al.  Chemical vapor detection using a capacitive micromachined ultrasonic transducer. , 2011, Analytical chemistry.

[8]  Dominique Rebière,et al.  Synthesis and evaluation of fluoropolyol isomers as saw microsensor coatings: role of humidity and temperature , 1998 .

[9]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[10]  J. Steinhanses,et al.  Thermal desorption—gas chromatography of some organophosphates and S-mustard after trapping on Tenax , 1990 .

[11]  R Chung,et al.  Rational materials design of sorbent coatings for explosives: applications with chemical sensors. , 2001, Talanta.

[12]  Jingjing Wang,et al.  Nerve gas sensor using film bulk acoustic resonator modified with a self-assembled Cu2+/11-mercaptoundecanoic acid bilayer , 2010 .

[13]  C. Dejous,et al.  Detection of GB and DMMP vapors by Love wave acoustic sensors using strong acidic fluoride polymers , 2004, IEEE Sensors Journal.

[14]  Jay W. Grate,et al.  Synthesis and evaluation of hexafluorodimethylcarbinol functionalized polymers as microsensor coatings , 1991 .

[15]  Gary A. Eiceman,et al.  A MEMS radio-frequency ion mobility spectrometer for chemical vapor detection , 2001 .

[16]  R. A. McGill,et al.  Determination of partition coefficients from surface acoustic wave vapor sensor responses and correlation with gas-liquid chromatographic partition coefficients , 1988 .

[17]  Susan L. Rose-Pehrsson,et al.  Smart sensor system for trace organophosphorus and organosulfur vapor detection employing a temperature-controlled array of surface acoustic wave sensors, automated sample preconcentration, and pattern recognition , 1993 .

[18]  Jin Hu,et al.  Hydrogen-Bond Acidic Hyperbranched Polymers for Surface Acoustic Wave (SAW) Sensors , 2004 .

[19]  Yadong Jiang,et al.  Synthesis and evaluation of a new polysiloxane as SAW sensor coatings for DMMP detection , 2008 .

[20]  Jay W Grate,et al.  Hydrogen-bond acidic polymers for chemical vapor sensing. , 2008, Chemical reviews.

[21]  Osmo Hänninen,et al.  Determination of soman and VX degradation products by an aspiration ion mobility spectrometry , 2001 .

[22]  K. Ward,et al.  Immobilization of cytochrome c oxidase into electrode-supported lipid bilayer membranes for in vitro cytochrome c sensing , 2006, IEEE Sensors Journal.

[23]  Yadong Jiang,et al.  A new polysiloxane coating on QCM sensor for DMMP vapor detection , 2009 .

[24]  Dominique Rebière,et al.  A love-wave gas sensor coated with functionalized polysiloxane for sensing organophosphorus compounds , 2001 .

[25]  Vesa M.A. Häkkinen,et al.  Identification of compounds relevant to the chemical weapons convention using selective gas chromatography detectors, gas chromatography-mass spectrometry and gas chromatography-Fourier transform infrared spectroscopy in an international trial proficiency test , 1996 .