NCICT: a computational solution to estimate organ doses for pediatric and adult patients undergoing CT scans

We developed computational methods and tools to assess organ doses for pediatric and adult patients undergoing computed tomography (CT) examinations. We used the International Commission on Radiological Protection (ICRP) reference pediatric and adult phantoms combined with the Monte Carlo simulation of a reference CT scanner to establish comprehensive organ dose coefficients (DC), organ absorbed dose per unit volumetric CT Dose Index (CTDIvol) (mGy/mGy). We also developed methods to estimate organ doses with tube current modulation techniques and size specific dose estimates. A graphical user interface was designed to obtain user input of patient- and scan-specific parameters, and to calculate and display organ doses. A batch calculation routine was also integrated into the program to automatically calculate organ doses for a large number of patients. We entitled the computer program, National Cancer Institute dosimetry system for CT(NCICT). We compared our dose coefficients with those from CT-Expo, and evaluated the performance of our program using CT patient data. Our pediatric DCs show good agreements of organ dose estimation with those from CT-Expo except for thyroid. Our results support that the adult phantom in CT-Expo seems to represent a pediatric individual between 10 and 15 years rather than an adult. The comparison of CTDIvol values between NCICT and dose pages from 10 selected CT scans shows good agreements less than 12% except for two cases (up to 20%). The organ dose comparison between mean and modulated mAs shows that mean mAs-based calculation significantly overestimates dose (up to 2.4-fold) to the organs in close proximity to lungs in chest and chest-abdomen-pelvis scans. Our program provides more realistic anatomy based on the ICRP reference phantoms, higher age resolution, the most up-to-date bone marrow dosimetry, and several convenient features compared to previous tools. The NCICT will be available for research purpose in the near future.

[1]  Martin Caon,et al.  Voxel-based computational models of real human anatomy: a review , 2004, Radiation and environmental biophysics.

[2]  Maryam Khatonabadi,et al.  The feasibility of a regional CTDIvol to estimate organ dose from tube current modulated CT exams. , 2013, Medical physics.

[3]  Choonsik Lee,et al.  An image-based skeletal dosimetry model for the ICRP reference newborn—internal electron sources , 2010, Physics in medicine and biology.

[4]  Cynthia H McCollough,et al.  The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: using CTDIvol to account for differences between scanners. , 2010, Medical physics.

[5]  B. Schmidt,et al.  A PC program for estimating organ dose and effective dose values in computed tomography , 1999, European Radiology.

[6]  Wesley E Bolch,et al.  Response functions for computing absorbed dose to skeletal tissues from photon irradiation—an update , 2011, Physics in medicine and biology.

[7]  CT scans in childhood and risk of leukaemia and brain tumours – Authors' reply , 2012, The Lancet.

[8]  K. F. Eckerman,et al.  Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn , 1987 .

[9]  Wesley E Bolch,et al.  Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation. , 2012, Medical physics.

[10]  Paul DeLuca,et al.  Realistic reference phantoms: An ICRP/ICRU joint effort , 2009, Annals of the ICRP.

[11]  T Hasegawa,et al.  Development of a web-based CT dose calculator: WAZA-ARI. , 2011, Radiation protection dosimetry.

[12]  Choonsik Lee,et al.  Assessing Organ Doses from Paediatric CT Scans—A Novel Approach for an Epidemiology Study (the EPI-CT Study) † , 2013, International journal of environmental research and public health.

[13]  Habib Zaidi,et al.  Computational anthropomorphic models of the human anatomy: the path to realistic Monte Carlo modeling in radiological sciences. , 2007, Annual review of biomedical engineering.

[14]  G. Stamm,et al.  [CT-expo--a novel program for dose evaluation in CT]. , 2002, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[15]  M. Prokop,et al.  Overranging at multisection CT: an underestimated source of excess radiation exposure. , 2010, Radiographics : a review publication of the Radiological Society of North America, Inc.

[16]  Human alimentary tract model for radiological protection. ICRP Publication 100. A report of The International Commission on Radiological Protection. , 2006, Annals of the ICRP.

[17]  H. Brisse,et al.  Comment on: Are the studies on cancer risk from CT scans biased by indication? Elements of answer from a large-scale cohort study in France , 2015, British Journal of Cancer.

[18]  R. Morin,et al.  Personalized technologist dose audit feedback for reducing patient radiation exposure from CT. , 2014, Journal of the American College of Radiology : JACR.

[19]  Ioannis Sechopoulos,et al.  The DICOM Radiation Dose Structured Report: What It Is and What It Is Not. , 2015, Journal of the American College of Radiology : JACR.

[20]  Daniel Lodwick,et al.  The UF family of reference hybrid phantoms for computational radiation dosimetry , 2010, Physics in medicine and biology.

[21]  Wesley E. Bolch,et al.  TH‐E‐211‐02: Estimation of Organ Doses in Reference Pediatric Individuals Undergoing Computed Tomography Using Monte Carlo Simulations , 2011 .

[22]  Perry B. Johnson,et al.  An image-based skeletal dosimetry model for the ICRP reference adult male—internal electron sources , 2011, Physics in medicine and biology.

[23]  M. Hauptmann,et al.  Leukemia and brain tumors among children after radiation exposure from CT scans: design and methodological opportunities of the Dutch Pediatric CT Study , 2014, European Journal of Epidemiology.

[24]  Stephanie Lamart,et al.  Computational lymphatic node models in pediatric and adult hybrid phantoms for radiation dosimetry , 2013, Physics in medicine and biology.

[25]  C. Potter ICRP Publication 100 Human Alimentary Tract Model for Radiological Protection. , 2007 .

[26]  Sheila Weinmann,et al.  Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996-2010. , 2012, JAMA.

[27]  Ehsan Samei,et al.  Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories. , 2014, Medical physics.

[28]  M. Little,et al.  Database of normalised computed tomography dose index for retrospective CT dosimetry , 2014, Journal of radiological protection : official journal of the Society for Radiological Protection.

[29]  Wesley E Bolch,et al.  Monte Carlo simulations of adult and pediatric computed tomography exams: validation studies of organ doses with physical phantoms. , 2012, Medical physics.

[30]  Maryam Khatonabadi,et al.  A comparison of methods to estimate organ doses in CT when utilizing approximations to the tube current modulation function. , 2012, Medical physics.

[31]  X George Xu,et al.  An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history , 2014, Physics in medicine and biology.

[32]  Steven L Simon,et al.  Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations. , 2011, Medical physics.

[33]  John M Boone,et al.  Reply to "Comment on the 'Report of AAPM TG 204: Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations'" [AAPM Report 204, 2011]. , 2012, Medical physics.

[34]  Peter F Caracappa,et al.  Comparison of two types of adult phantoms in terms of organ doses from diagnostic CT procedures , 2010, Physics in medicine and biology.

[35]  R. Vetter ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection , 2008 .

[36]  J. Valentin Basic anatomical and physiological data for use in radiological protection: reference values , 2002, Annals of the ICRP.