Comparison of six microwave antennas for hyperthermia treatment of cancer: sar results for single antennas and arrays.

Interstitial techniques of inserting catheters into tumors for the purpose of applying therapeutic irradiation and hyperthermia are in widespread use. Several miniature microwave antenna designs are currently used for these treatments. These include multisection, hot-tip, 2- and 3-node, dipole and helical antennas, all of which are commercially available. The antenna designs are diverse enough to have a dramatic effect on the power deposition patterns either as single antennas or when used in arrays. Aside from the dipole antenna, most of the antennas have never been evaluated experimentally or theoretically in arrays, although the array configuration is used in the vast majority of all clinical treatments. Power deposition or SAR (specific absorption rate) tests were run in muscle equivalent phantom. Single antennas were evaluated at 400 points in a plane and isoSAR contours drawn, normalized to maximum SAR. Single antennas were also compared in large and small diameter catheters to evaluate catheter dependent antenna performance. The dipole, multisection, hot-tip and helical antennas were evaluated in arrays of four antennas located at the corners of a square, spaced 2.0 cm apart. Arrays of antennas were evaluated at 441 points in three planes orthogonal to the antenna axes. Results in the single antenna studies showed that the dipole was less affected by snugness of catheter fit than the multisection, hot-tip or helical antennas. In large catheters, the latter three antennas showed more extreme tip heating performance. The 2- and 3-node antennas deposited only 20% SAR in the distal 30 mm of antenna length. In arrays, the multisection, hot-tip, and dipole antennas all yielded 80-90% SAR centrally in the central measurement plane. Comparing the three antennas, the dipole array deposited 20% more power centrally in a plane near the insertion point, and the multisection and hot-tip antenna designs deposited 10% more central power in a plane near the antenna tips. The helical antenna array deposited only 30% SAR centrally in the plane near the antenna tips and in the central plane. Only 10% SAR was measured centrally near the insertion point, as expected for tip-heating antennas. Finally, the clinical significance of the results is discussed as applied to human tumors undergoing hyperthermia treatments.

[1]  B.S. Trembly,et al.  SAR distributions for 915 MHz interstitial microwave antennas used in hyperthermia for cancer therapy , 1988, IEEE Transactions on Biomedical Engineering.

[2]  P. J. Hoopes,et al.  Experimental brain hyperthermia: techniques for heat delivery and thermometry. , 1991, International journal of radiation oncology, biology, physics.

[3]  The effect of air cooling on the radial temperature distribution of a single microwave hyperthermia antenna in vivo. , 1991, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[4]  J. Strohbehn,et al.  A Method for Measurement of the Permittivity of Thin Samples , 1979 .

[5]  Thermal conduction effects associated with temperature measurements in proximity to radiofrequency electrodes and microwave antennas. , 1989, International journal of radiation oncology, biology, physics.

[6]  J. Strohbehn,et al.  The effect of insertion depth on the theoretical SAR patterns of 915 MHz dipole antenna arrays for hyperthermia. , 1989, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[7]  J. Strohbehn,et al.  Interstitial hyperthermia and iridium brachytherapy in treatment of malignant glioma. A phase I clinical trial. , 1986, Journal of neurosurgery.

[8]  M. F. Iskander,et al.  Performance comparison of available interstitial antennas for microwave hyperthermia , 1989 .

[9]  J. Strohbehn,et al.  SAR Patterns from an Interstitial Microwave Antenna-Array Hyperthermia System , 1986 .

[10]  D. V. Giri,et al.  Errata: The insulated dipole antenna in a relatively dense medium , 1973 .

[11]  William T. Joines,et al.  The determination of the electromagnetic field and SAR pattern of an interstitial applicator in a dissipative dielectric medium , 1988 .

[12]  B. Stuart Trembly,et al.  The Effects of Driving Frequency and Antenna Length on Power Deposition Within a Microwave Antenna Array Used for Hyperthermia , 1985, IEEE Transactions on Biomedical Engineering.

[13]  J W Strohbehn,et al.  Interstitial hyperthermia in combination with brachytherapy. , 1983, Radiology.

[14]  J. C. Lin,et al.  Interstitial microwave antennas for thermal therapy. , 1987, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[15]  P. F. Turner Interstitial Equal-Phased Arrays for EM Hyperthermia , 1986 .

[16]  A. W. Guy,et al.  Analyses of Electromagnetic Fields Induced in Biological Tissues by Thermographic Studies on Equivalent Phantom Models , 1971 .

[17]  J. Strohbehn,et al.  The Electromagnetic Field of an Insulated Antenna in a Conducting Or Dielectric Medium , 1983 .

[18]  J. Strohbehn Interstitial Techniques for Hyperthermia , 1987 .

[19]  J W Strohbehn,et al.  A theoretical comparison of the temperature distributions produced by three interstitial hyperthermia systems. , 1986, International journal of radiation oncology, biology, physics.

[20]  J W Strohbehn,et al.  Absorbed power deposition for various insertion depths for 915 MHz interstitial dipole antenna arrays: experiment versus theory. , 1990, International journal of radiation oncology, biology, physics.

[21]  W. Joines,et al.  The calculated and measured temperature distribution of a phased interstitial antenna array (invasive applicators) , 1990 .

[22]  P. Stauffer,et al.  Implantable helical coil microwave antenna for interstitial hyperthermia. , 1988, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[23]  E. Grant,et al.  A broad band microwave applicator for heating tumours. , 1980, The British journal of radiology.

[24]  Electromagnetic Syringe , 1978, IEEE Transactions on Biomedical Engineering.

[25]  John W. Strohbehn,et al.  Theoretical and experimental SAR distributions for interstitial dipole antenna arrays used in hyperthermia , 1989 .

[26]  S. B. Field,et al.  Physics and technology of hyperthermia , 1987 .

[27]  E S Sternick,et al.  Performance characteristics of a helical microwave interstitial antenna for local hyperthermia. , 1987, Medical physics.

[28]  J. Strohbehn,et al.  Control of the SAR Pattern Within an Interstitial Microwave Array through Variation of Antenna Driving Phase , 1986 .

[29]  M. Iskander,et al.  Design optimization of interstitial antennas , 1989, IEEE Transactions on Biomedical Engineering.

[30]  Kenneth R. Foster,et al.  Thermal Properties of Tissue Equivalent Phantom Materials , 1984, IEEE Transactions on Biomedical Engineering.

[31]  Microwave hyperthermia induced by a phased interstitial antenna array , 1990 .

[32]  K S Lam,et al.  A new design of microwave interstitial applicators for hyperthermia with improved treatment volume. , 1986, International journal of radiation oncology, biology, physics.

[33]  Design and performance of a high speed driver circuit for PIN diode switches used in microwave hyperthermia. , 1989, Journal of biomedical engineering.