The correlation between audible noise and corona current in time domain caused by single positive corona source on the conductor

Audible noise and corona current are two main DC corona effects, and they may both highly depend on the characteristics of space charges generated during corona discharge. However, relatively little investigation has previously been done on the correlation between them especially in time-domain. In the present work, the time-domain waveforms of audible noise and corona current generated by single positive corona source were recorded simultaneously. Their characteristics were carefully analyzed and found to be closely related. It was found that both the audible noise and the corona current consisted of repetitive pulses, and one-to-one relationship in time could be observed and confirmed between them. Furthermore, a linear correlation between the peak-to-peak values of audible noise pulses and the amplitude of corona current pulses was obtained. Empirical formulas with the same forms for them were derived to further prove the linear correlation. The close correlation between the audible noise and the corona current was interpreted qualitatively in the presented work and found to be highly related to the generated space charges.

[1]  Ueli Straumann,et al.  Mechanism of the tonal emission from ac high voltage overhead transmission lines , 2011 .

[2]  Lu,et al.  Calculation Model for the Propagation of Audible Noise from High Voltage Transmission Lines , 2013 .

[3]  P. Sarma Maruvada,et al.  Corona Performance of High Voltage Transmission Lines , 2000 .

[4]  Jinliang He,et al.  Influence of wave propagation process on measurement of corona current , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[5]  J. E. Piercy,et al.  Review of noise propagation in the atmosphere. , 1977, The Journal of the Acoustical Society of America.

[6]  R. Ono,et al.  Visualization of Streamer Channels and Shock Waves Generated by Positive Pulsed Corona Discharge Using Laser Schlieren Method , 2004 .

[7]  K. Charrada,et al.  Simulation of Expansion of Thermal Shock and Pressure Waves Inducaed by a Streamer Dynamics in Positive DC Corona Discharges , 2013, IEEE Transactions on Plasma Science.

[8]  N.M. Ijumba,et al.  Corona Audible Noise Measurements in a Small Indoor Corona Cage under HVDC Voltages , 2006, 2006 International Conference on Power System Technology.

[9]  K. Attenborough,et al.  Sound propagation from a dipole source near an impedance plane , 1997 .

[10]  Task Force Measurement of Audible Noise from Transmission Lines , 1981, IEEE Transactions on Power Apparatus and Systems.

[11]  O. Kalenderli,et al.  Determination of source voltage from audible corona noise by neural networks , 2009, IEEE Transactions on Dielectrics and Electrical Insulation.

[12]  V. Chartier,et al.  Formulas for Predicting Audible Noise from Overhead High Voltage AC and DC Lines , 1981, IEEE Transactions on Power Apparatus and Systems.

[13]  Trinh N. Giao,et al.  Modes of Corona Discharges in Air , 1968 .

[14]  Aljo Mujcic,et al.  Corona noise characteristics in high voltage PLC channel , 2003, IEEE International Conference on Industrial Technology, 2003.

[15]  P. Herzog,et al.  Modelling of negative point-to-plane corona loudspeaker , 2001 .

[16]  D. J. Bosack,et al.  Spectral Characteristics of Acoustic Noise from Metallic Protrusions and Water Droplets in High Electric Fields , 1974 .

[17]  M. R. Amin Fast Time Analysis of Intermittent Point-to-Plane Corona in Air I. The Positive Point Burst Pulse Corona , 1954 .

[18]  Deming Yu,et al.  Impact of Surface Roughness on Corona Discharge for 30-year Operating Conductors in 500-kV ac Power Transmission Line , 2012, IEEE Transactions on Power Delivery.

[19]  Yi Hu,et al.  Speech enhancement based on wavelet thresholding the multitaper spectrum , 2004, IEEE Transactions on Speech and Audio Processing.

[20]  J. Rouat,et al.  Wavelet speech enhancement based on the Teager energy operator , 2001, IEEE Signal Processing Letters.

[22]  Dennis A. Bohn Environmental Effects on the Speed of Sound , 1988 .

[23]  X. Cui,et al.  Accurate measurement of original current pulses because of positive corona in the coaxial cylindrical arrangement , 2015 .

[24]  Xiang Cui,et al.  Time-domain characteristics of the audible noise generated by single corona source under positive voltage , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[25]  J. M. K. MacAlpine,et al.  The role of charged particles in the positive corona-generated photon count in a rod to plane air gap , 2013 .

[26]  Xingming Bian,et al.  Surface roughness effects on the corona discharge intensity of long-term operating conductors , 2012 .

[27]  Jinliang He,et al.  Specific characteristics of negative corona currents generated in short point-plane gap , 2013 .

[28]  A.C. Baker,et al.  Investigation of the corona performance of conductor bundles for 800-kV transmission , 1975, IEEE Transactions on Power Apparatus and Systems.

[29]  J. Macalpine,et al.  Influence of aged conductor surface conditions on AC corona-generated audible noise with a corona cage , 2012, IEEE Transactions on Dielectrics and Electrical Insulation.

[30]  G. W. Trichel The Mechanism of the Negative Point to Plane Corona Near Onset , 1938 .