Required transition from research to clinical application: Report on the 4D treatment planning workshops 2014 and 2015.

Since 2009, a 4D treatment planning workshop has taken place annually, gathering researchers working on the treatment of moving targets, mainly with scanned ion beams. Topics discussed during the workshops range from problems of time resolved imaging, the challenges of motion modelling, the implementation of 4D capabilities for treatment planning, up to different aspects related to 4D dosimetry and treatment verification. This report gives an overview on topics discussed at the 4D workshops in 2014 and 2015. It summarizes recent findings, developments and challenges in the field and discusses the relevant literature of the recent years. The report is structured in three parts pointing out developments in the context of understanding moving geometries, of treating moving targets and of 4D quality assurance (QA) and 4D dosimetry. The community represented at the 4D workshops agrees that research in the context of treating moving targets with scanned ion beams faces a crucial phase of clinical translation. In the coming years it will be important to define standards for motion monitoring, to establish 4D treatment planning guidelines and to develop 4D QA tools. These basic requirements for the clinical application of scanned ion beams to moving targets could e.g. be determined by a dedicated ESTRO task group. Besides reviewing recent research results and pointing out urgent needs when treating moving targets with scanned ion beams, the report also gives an outlook on the upcoming 4D workshop organized at the University Medical Center Groningen (UMCG) in the Netherlands at the end of 2016.

[1]  C Bert,et al.  A breathing thorax phantom with independently programmable 6D tumour motion for dosimetric measurements in radiation therapy , 2012, Physics in medicine and biology.

[2]  Christopher Kurz,et al.  Comparing cone-beam CT intensity correction methods for dose recalculation in adaptive intensity-modulated photon and proton therapy for head and neck cancer , 2015, Acta oncologica.

[3]  Wei Liu,et al.  Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer. , 2016, International journal of radiation oncology, biology, physics.

[4]  Tobias Gass,et al.  Total Variation Regularization of Displacements in Parametric Image Registration , 2014, ABDI@MICCAI.

[5]  David Thomas,et al.  A novel fast helical 4D-CT acquisition technique to generate low-noise sorting artifact-free images at user-selected breathing phases. , 2014, International journal of radiation oncology, biology, physics.

[6]  Ping Xia,et al.  Assessing Feasibility of Real-Time Ultrasound Monitoring in Stereotactic Body Radiotherapy of Liver Tumors , 2013, Technology in cancer research & treatment.

[7]  I. Chetty,et al.  A novel approach for evaluation of prostate deformation and associated dosimetric implications in IGRT of the prostate. , 2014, Medical physics.

[8]  George T. Y. Chen,et al.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.

[9]  Katsuyuki Tanimoto,et al.  Carbon-Ion Pencil Beam Scanning Treatment With Gated Markerless Tumor Tracking: An Analysis of Positional Accuracy. , 2016, International journal of radiation oncology, biology, physics.

[10]  Francesca Albertini,et al.  Robustness of the Voluntary Breath-Hold Approach for the Treatment of Peripheral Lung Tumors Using Hypofractionated Pencil Beam Scanning Proton Therapy. , 2016, International journal of radiation oncology, biology, physics.

[11]  Joe Y. Chang,et al.  Long-term outcomes after proton therapy, with concurrent chemotherapy, for stage II-III inoperable non-small cell lung cancer. , 2015, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[12]  Harald Paganetti,et al.  Motion mitigation for lung cancer patients treated with active scanning proton therapy. , 2015, Medical physics.

[13]  S. Rit,et al.  On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion. , 2009, Medical physics.

[14]  Radhe Mohan,et al.  Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method. , 2008, International journal of radiation oncology, biology, physics.

[15]  M. Durante,et al.  Assessment of uncertainties in treatment planning for scanned ion beam therapy of moving tumors. , 2013, International journal of radiation oncology, biology, physics.

[16]  Marc Modat,et al.  Cone-Beam Computed Tomography and Deformable Registration-Based “Dose of the Day” Calculations for Adaptive Proton Therapy , 2015 .

[17]  P. Evans,et al.  In vivo liver tracking with a high volume rate 4D ultrasound scanner and a 2D matrix array probe , 2012, Physics in medicine and biology.

[18]  Dimitre Hristov,et al.  Ultrasound Imaging in Radiation Therapy: From Interfractional to Intrafractional Guidance , 2015, Cureus.

[19]  H. Ishikawa,et al.  High-dose concurrent chemo–proton therapy for Stage III NSCLC: preliminary results of a Phase II study , 2014, Journal of radiation research.

[20]  G Baroni,et al.  Motion prediction in MRI-guided radiotherapy based on interleaved orthogonal cine-MRI , 2016, Physics in medicine and biology.

[21]  D Meer,et al.  A study on repainting strategies for treating moderately moving targets with proton pencil beam scanning at the new Gantry 2 at PSI , 2010, Physics in medicine and biology.

[22]  D. Schardt,et al.  Magnetic scanning system for heavy ion therapy , 1993 .

[23]  R. Castillo,et al.  A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets , 2009, Physics in medicine and biology.

[24]  Wei Liu,et al.  Robust optimization in intensity-modulated proton therapy to account for anatomy changes in lung cancer patients. , 2015, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[25]  Dimitre Hristov,et al.  Telerobotic system concept for real-time soft-tissue imaging during radiotherapy beam delivery. , 2010, Medical physics.

[26]  Steve Webb,et al.  Quantifying the effect of respiratory motion on lung tumour dosimetry with the aid of a breathing phantom with deforming lungs , 2006, Physics in medicine and biology.

[27]  Davide Fontanarosa,et al.  Review of ultrasound image guidance in external beam radiotherapy: I. Treatment planning and inter-fraction motion management , 2015, Physics in medicine and biology.

[28]  Marco Riboldi,et al.  Liver 4DMRI: A retrospective image-based sorting method. , 2015, Medical physics.

[29]  A. Lomax,et al.  The effectiveness of combined gating and re-scanning for treating mobile targets with proton spot scanning. An experimental and simulation-based investigation , 2014, Physics in medicine and biology.

[30]  Jeffrey C Bamber,et al.  The effect of object speed and direction on the performance of 3D speckle tracking using a 3D swept-volume ultrasound probe. , 2011, Physics in medicine and biology.

[31]  Orcun Goksel,et al.  Motion Tracking in 2D Ultrasound Using Vessel Models and Robust Optic-Flow , 2015 .

[32]  Liyong Lin,et al.  First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer. , 2016, International journal of radiation oncology, biology, physics.

[33]  Brett Byram,et al.  3-D phantom and in vivo cardiac speckle tracking using a matrix array and raw echo data , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[34]  Richard Ansorge,et al.  Sub-second pencil beam dose calculation on GPU for adaptive proton therapy , 2015, Physics in medicine and biology.

[35]  Qianyi Xu,et al.  A novel respiratory detection method based on automated analysis of ultrasound diaphragm video. , 2006, Medical physics.

[36]  A. Berman,et al.  Proton Beam Therapy for Non-Small Cell Lung Cancer: Current Clinical Evidence and Future Directions , 2015, Cancers.

[37]  S. Mori,et al.  Carbon-ion scanning lung treatment planning with respiratory-gated phase-controlled rescanning: simulation study using 4-dimensional CT data , 2014, Radiation oncology.

[38]  Marco Durante,et al.  Motion mitigation in intensity modulated particle therapy by internal target volumes covering range changes. , 2012, Medical physics.

[39]  Richard Ansorge,et al.  Fast Pencil Beam Dose Calculation for Proton Therapy Using a Double-Gaussian Beam Model , 2015, Front. Oncol..

[40]  Jeffrey C Bamber,et al.  4D ultrasound speckle tracking of intra-fraction prostate motion: a phantom-based comparison with x-ray fiducial tracking using CyberKnife , 2014, Physics in medicine and biology.

[41]  K Parodi,et al.  Ion beam tracking using ultrasound motion detection. , 2014, Medical physics.

[42]  Tom Depuydt,et al.  Tumour Movement in Proton Therapy: Solutions and Remaining Questions: A Review , 2015, Cancers.

[43]  Shinichi Shimizu,et al.  A Proton Beam Therapy System Dedicated to Spot-Scanning Increases Accuracy with Moving Tumors by Real-Time Imaging and Gating and Reduces Equipment Size , 2014, PloS one.

[44]  A J Lomax,et al.  Respiratory liver motion estimation and its effect on scanned proton beam therapy , 2012, Physics in medicine and biology.

[45]  Christoph Bert,et al.  4D optimization of scanned ion beam tracking therapy for moving tumors , 2014, Physics in medicine and biology.

[46]  Geoffrey D. Hugo,et al.  Advances in 4D radiation therapy for managing respiration: part I - 4D imaging. , 2012, Zeitschrift fur medizinische Physik.

[47]  Wolfgang Enghardt,et al.  First test of the prompt gamma ray timing method with heterogeneous targets at a clinical proton therapy facility , 2015, Physics in medicine and biology.

[48]  George Starkschall,et al.  Verification of four-dimensional photon dose calculations. , 2009, Medical physics.

[49]  J. Adler,et al.  Robotic Motion Compensation for Respiratory Movement during Radiosurgery , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[50]  Christoph Bert,et al.  Respiratory motion management in particle therapy. , 2010, Medical physics.

[51]  M. Durante,et al.  Treatment Parameters Optimization to Compensate for Interfractional Anatomy Variability and Intrafractional Tumor Motion , 2015, Front. Oncol..

[52]  James M Lamb,et al.  A Method for Assessing Ground-Truth Accuracy of the 5DCT Technique. , 2015, International journal of radiation oncology, biology, physics.

[53]  Heng Li,et al.  Clinical implementation of intensity modulated proton therapy for thoracic malignancies. , 2014, International journal of radiation oncology, biology, physics.

[54]  Thomas Bortfeld,et al.  Visualization of a variety of possible dosimetric outcomes in radiation therapy using dose-volume histogram bands. , 2012, Practical radiation oncology.

[55]  Charis Kontaxis,et al.  Dosimetric feasibility of intensity modulated proton therapy in a transverse magnetic field of 1.5 T , 2015, Physics in medicine and biology.

[56]  Jan Seuntjens,et al.  A deformable phantom for 4D radiotherapy verification: design and image registration evaluation. , 2008, Medical physics.

[57]  J. Lagendijk,et al.  Dosimetric feasibility of MRI-guided external beam radiotherapy of the kidney , 2013, Physics in medicine and biology.

[58]  S. Crozier,et al.  Proton beam deflection in MRI fields: Implications for MRI-guided proton therapy. , 2015, Medical physics.

[59]  Joe Y. Chang,et al.  Improving radiation conformality in the treatment of non-small cell lung cancer. , 2010, Seminars in radiation oncology.

[60]  K Parodi,et al.  Ultrasound tracking for intra-fractional motion compensation in radiation therapy. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[61]  S Nill,et al.  The comparative performance of four respiratory motion predictors for real-time tumour tracking , 2011, Physics in medicine and biology.

[62]  Takuji Furukawa,et al.  Amplitude-based gated phase-controlled rescanning in carbon-ion scanning beam treatment planning under irregular breathing conditions using lung and liver 4DCTs , 2014, Journal of radiation research.

[63]  Sébastien Ourselin,et al.  Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for "dose of the day" calculations. , 2014, Medical physics.

[64]  Dirk Boye,et al.  Adequate margin definition for scanned particle therapy in the incidence of intrafractional motion. , 2013, Physics in medicine and biology.

[65]  Heng Li,et al.  On the interplay effects with proton scanning beams in stage III lung cancer. , 2014, Medical physics.

[66]  M. Lachaine,et al.  INTRAFRACTIONAL PROSTATE MOTION MANAGEMENT WITH THE CLARITY AUTOSCAN SYSTEM , 2013 .

[67]  O Somphone,et al.  The 2014 liver ultrasound tracking benchmark , 2015, Physics in medicine and biology.

[68]  Timothy D. Solberg,et al.  First clinical investigation of CBCT and deformable registration for adaptive proton therapy of lung cancer , 2016 .

[69]  Jan-Jakob Sonke,et al.  Challenges of radiotherapy: report on the 4D treatment planning workshop 2013. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[70]  G Sportelli,et al.  First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system , 2014, Physics in medicine and biology.

[71]  Joao Seco,et al.  Breathing interplay effects during proton beam scanning: simulation and statistical analysis , 2009, Physics in medicine and biology.

[72]  Davide Fontanarosa,et al.  Review of ultrasound image guidance in external beam radiotherapy part II: intra-fraction motion management and novel applications , 2016, Physics in medicine and biology.

[73]  C Bert,et al.  Motion in radiotherapy: particle therapy , 2011, Physics in medicine and biology.

[74]  A J Lomax,et al.  Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients , 2013, Physics in medicine and biology.

[75]  S. Korreman Motion in radiotherapy: photon therapy , 2012, Physics in medicine and biology.

[76]  Andrew Thomas,et al.  Beam-specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors. , 2015, Journal of applied clinical medical physics.

[77]  H. Paganetti Range uncertainties in proton therapy and the role of Monte Carlo simulations , 2012, Physics in medicine and biology.

[78]  Philippe C. Cattin,et al.  Model-guided respiratory organ motion prediction of the liver from 2D ultrasound , 2014, Medical Image Anal..

[79]  Jürgen Beuthan,et al.  Sagittal laser optical tomography for imaging of rheumatoid finger joints. , 2004, Physics in medicine and biology.

[80]  Damien Charles Weber,et al.  Improving 4D plan quality for PBS-based liver tumour treatments by combining online image guided beam gating with rescanning , 2015, Physics in medicine and biology.

[81]  A J Lomax,et al.  Independent dose calculations for commissioning, quality assurance and dose reconstruction of PBS proton therapy , 2015, Physics in medicine and biology.

[82]  Rosalind Perrin,et al.  Four-Dimensional Dose Reconstruction for Scanned Proton Therapy Using Liver 4DCT-MRI. , 2016, International journal of radiation oncology, biology, physics.

[83]  Heng Li,et al.  Evaluation and mitigation of the interplay effects of intensity modulated proton therapy for lung cancer in a clinical setting. , 2014, Practical radiation oncology.

[84]  Wei Liu,et al.  Impact of respiratory motion on worst-case scenario optimized intensity modulated proton therapy for lung cancers. , 2015, Practical radiation oncology.

[85]  Chan Hyeong Kim,et al.  Prompt gamma measurements for locating the dose falloff region in the proton therapy , 2006 .

[86]  A Schweikard,et al.  Evaluating and comparing algorithms for respiratory motion prediction , 2013, Physics in medicine and biology.

[87]  P. Evans,et al.  Speckle tracking in a phantom and feature-based tracking in liver in the presence of respiratory motion using 4D ultrasound , 2010, Physics in medicine and biology.

[88]  Rojano Kashani,et al.  Technical note: a deformable phantom for dynamic modeling in radiation therapy. , 2007, Medical physics.

[89]  Peter Kazanzides,et al.  In vivo reproducibility of robotic probe placement for a novel ultrasound-guided radiation therapy system , 2014, Journal of medical imaging.

[90]  Shinji Sato,et al.  Moving target irradiation with fast rescanning and gating in particle therapy. , 2010, Medical physics.

[91]  David J. Hawkes,et al.  Combining Image Registration, Respiratory Motion Modelling, and Motion Compensated Image Reconstruction , 2014, WBIR.

[92]  K. Herfarth,et al.  Scanned ion beam therapy for prostate carcinoma , 2016, Strahlentherapie und Onkologie.

[93]  Julia Bauer,et al.  Hypofractionated carbon ion therapy delivered with scanned ion beams for patients with hepatocellular carcinoma – feasibility and clinical response , 2013, Radiation Oncology.

[94]  V Patera,et al.  Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u 12C beam , 2014, Physics in medicine and biology.

[95]  Carlo Fiorini,et al.  First clinical application of a prompt gamma based in vivo proton range verification system. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[96]  A. Lomax,et al.  First experimental results of motion mitigation by continuous line scanning of protons , 2014, Physics in medicine and biology.

[97]  F. Licciulli,et al.  The INSIDE project: Innovative solutions for in-beam dosimetry in hadrontherapy , 2015 .

[98]  P Boesiger,et al.  4D MR imaging of respiratory organ motion and its variability , 2007, Physics in medicine and biology.

[99]  Ross Berbeco,et al.  Use of a realistic breathing lung phantom to evaluate dose delivery errors. , 2010, Medical physics.

[100]  Quan Chen,et al.  Objective assessment of deformable image registration in radiotherapy: a multi-institution study. , 2007, Medical physics.

[101]  M Goitein,et al.  Calculation of the uncertainty in the dose delivered during radiation therapy. , 1985, Medical physics.

[102]  Joao Seco,et al.  Proton range verification through prompt gamma-ray spectroscopy , 2014, Physics in medicine and biology.

[103]  K Souris,et al.  TH-A-19A-08: Intel Xeon Phi Implementation of a Fast Multi-Purpose Monte Carlo Simulation for Proton Therapy. , 2014, Medical physics.

[104]  Antje Knopf,et al.  Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study. , 2013, Medical physics.

[105]  Weixin Xie,et al.  Online 4-D CT Estimation for Patient-Specific Respiratory Motion Based on Real-Time Breathing Signals , 2010, MICCAI.

[106]  E. Pedroni,et al.  The 200-MeV proton therapy project at the Paul Scherrer Institute: conceptual design and practical realization. , 1995, Medical physics.

[107]  T. Pawlicki,et al.  Proton therapy dose calculations on GPU: advances and challenges , 2012 .

[108]  Gregory C Sharp,et al.  Prediction of respiratory tumour motion for real-time image-guided radiotherapy. , 2004, Physics in medicine and biology.

[109]  Sébastien Ourselin,et al.  Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm. , 2015, Medical physics.

[110]  David J. Hawkes,et al.  Respiratory motion models: a review. , 2013 .

[111]  Heinz Handels,et al.  A Diffeomorphic MLR Framework for Surrogate-based Motion Estimation and Situation-adapted Dose Accumulation , 2012 .

[112]  Feasibility of polymer gel dosimetry measurements in a dynamic porcine lung phantom , 2015 .

[113]  A. Schmidt-Richberg,et al.  Multivariate regression approaches for surrogate-based diffeomorphic estimation of respiratory motion in radiation therapy. , 2014, Physics in medicine and biology.

[114]  John H. Lewis,et al.  4D cone beam CT-based dose assessment for SBRT lung cancer treatment , 2016, Physics in medicine and biology.

[115]  Xiaodong Zhang,et al.  Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence. , 2015, International journal of radiation oncology, biology, physics.

[116]  K. Brock,et al.  Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue. , 2006, International journal of radiation oncology, biology, physics.

[117]  A J Lomax,et al.  Deformable motion reconstruction for scanned proton beam therapy using on-line x-ray imaging , 2013, Physics in medicine and biology.

[118]  Joe Y. Chang,et al.  Proton therapy in clinical practice , 2011, Chinese journal of cancer.

[119]  Pierre Léger,et al.  MO-AB-BRA-09: Temporally Realistic Manipulation a 4D Biomechanical Lung Phantom for Evaluation of Simultaneous Registration and Segmentation , 2015 .

[120]  T Kron,et al.  Is it sensible to "deform" dose? 3D experimental validation of dose-warping. , 2012, Medical physics.