Comparison of ultrasonic array imaging algorithms for nondestructive evaluation

Ultrasonic array imaging algorithms have been widely used and developed in nondestructive evaluation in the last 10 years. In this paper, three imaging algorithms [total focusing method (TFM), phase-coherent imaging (PCI), and spatial compounding imaging (SCI)] are compared through both simulation and experimental measurements. In the simulation, array data sets were generated using a hybrid forward model containing a single defect among a multitude of randomly distributed point scatterers to represent backscatter from material microstructure. The number of point scatterers per unit area and their scattering amplitude were optimized to reduce computation cost. The SNR of the final images and their resolution were used to indicate the quality of the different imaging algorithms. The images of different types of defects (point reflectors and planar cracks) were used to investigate the robustness of the imaging algorithms. It is shown that PCI can yield higher image resolution and higher SNR for defects in material with weak backscatter than TFM, but that the images of cracks are distorted. Overall, TFM is the most robust algorithm across a range of different types of defects. It is also shown that the detection limit of all three imaging algorithms is almost equal for weakly scattering defects.

[1]  G. Blacquière,et al.  Inverse wave field extrapolation: a different NDI approach to imaging defects , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  L. Schmerr Fundamentals of Ultrasonic Nondestructive Evaluation , 1998 .

[3]  Paul D. Wilcox,et al.  Array Imaging of Noisy Materials , 2011 .

[4]  Paul D. Wilcox,et al.  Defect detection using ultrasonic arrays: The multi-mode total focusing method , 2010 .

[5]  I. Yalda-Mooshabad,et al.  Modeling Ultrasonic Microstructural Noise in Titanium Alloys , 1993 .

[6]  P. Wilcox,et al.  Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation , 2005 .

[7]  H. Pursey,et al.  The field and radiation impedance of mechanical radiators on the free surface of a semi-infinite isotropic solid , 1954, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[8]  Paul D. Wilcox,et al.  Ultrasonic arrays for non-destructive evaluation: A review , 2006 .

[9]  T. Hall,et al.  2-D companding for noise reduction in strain imaging , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  C Fritsch,et al.  Phase coherence imaging of grained materials , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Alexander Velichko,et al.  A generalized approach for efficient finite element modeling of elastodynamic scattering in two and three dimensions. , 2010, The Journal of the Acoustical Society of America.

[12]  S.W. Smith,et al.  Speckle Pattern Correlation with Lateral Aperture Translation: Experimental Results and Implications for Spatial Compounding , 1986, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  M. Bance,et al.  A split-aperture transmit beamforming technique with phase coherence grating lobe suppression , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  Dominique Placko,et al.  Modeling of phased array transducers. , 2005, The Journal of the Acoustical Society of America.

[15]  Steve Mahaut,et al.  Development of phased array techniques to improve characterization of defect located in a component of complex geometry. , 2002, Ultrasonics.

[16]  Alexander Velichko,et al.  An analytical comparison of ultrasonic array imaging algorithms. , 2010, The Journal of the Acoustical Society of America.

[17]  Frank J. Margetan,et al.  Predicting ultrasonic grain noise in polycrystals: A Monte Carlo model , 1996 .

[18]  Alexander Velichko,et al.  STRATEGIES FOR ULTRASOUND IMAGING USING TWO‐DIMENSIONAL ARRAYS , 2010 .

[19]  J.A. Johnson,et al.  Coherent-array imaging using phased subarrays. Part I: basic principles , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  P.D. Wilcox,et al.  The wavenumber algorithm for full-matrix imaging using an ultrasonic array , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  D. Hodgkinson,et al.  Optimized Inspection of Thin-Walled Pipe Welds Using Advanced Ultrasonic Techniques , 2005 .

[22]  P. Shankar Speckle Reduction in Ultrasound B-Scans Using Weighted Averaging in Spatial Compounding , 1986, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  J. Camacho,et al.  Phase Coherence Imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  P. Wilcox,et al.  Defect characterization using an ultrasonic array to measure the scattering coefficient matrix , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  T. Varghese,et al.  Improved parametric imaging of scatterer size estimates using angular compounding , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.