Abstract The critical heat flux (CHF) condition is an important parameter in the design and operation of nuclear reactor fuel rod assemblies. It has traditionally been evaluated using look-up tables or empirical correlations. In the present paper, a set of relations, in the form of a one-dimensional three-field model, is presented which enables a mechanistic prediction of high-quality CHF known as dry out. This also allows a more fundamental treatment of post-dry out heat transfer. The ensemble of relations is validated by comparing the predictions with data obtained from the TPTF test series of JAERI and the THTF test series of ORNL. The rod bundles have been modelled on a sub-channel basis. The effect of spacer grids on the flow and heat transfer has been studied by including their geometrical characteristics only. Good predictions of the dry out location and the post-dry out variation of the rod temperature are obtained over the range of parameters investigated in these tests, namely, in the pressure range of 30–130 bar, mass flux range of 50–800 kg/m 2  s and inlet condition ranging from sub-cooled to an inlet quality of 0.89.

[1]  Thomas K.S. Liang,et al.  Development of LOCA licensing calculation capability with RELAP5-3D in accordance with Appendix K of 10 CFR 50.46 , 2002 .

[2]  Norbert Hoyer,et al.  Calculation of dryout and post-dryout heat transfer for tube geometry , 1998 .

[3]  H. Kumamaru,et al.  Investigation of pre- and post-dryout heat transfer of steam-water two-phase flow in a rod bundle , 1987 .

[4]  Y. Katto A generalized correlation of critical heat flux for the forced convection boiling in vertical uniformly heated round tubes , 1978 .

[5]  E. Royer,et al.  The 1995 look-up table for critical heat flux in tubes , 1996 .

[6]  D. G. Morris,et al.  Dispersed-Flow Film Boiling Heat Transfer Data near Spacer Grids in a Rod Bundle , 1983 .

[7]  G. F. Hewitt,et al.  Phenomenological modelling of non-equilibrium flows with phase change , 1990 .

[8]  G. Hewitt,et al.  Annular two-phase flow , 1970 .

[9]  H. Kumamaru,et al.  Critical Heat Flux for Uniformly Heated Rod Bundle under High-Pressure, Low-Flow and Mixed Inlet Conditions , 1989 .

[10]  J. Thome,et al.  Convective Boiling and Condensation , 1972 .

[11]  D. Bestion,et al.  The physical closure laws in the CATHARE code , 1990 .

[12]  Tatsuhiro Ueda,et al.  Critical heat flux and droplet entrainment rate in boiling of falling liquid films , 1981 .

[13]  D. Groeneveld,et al.  1986 AECL-UO Critical Heat Flux Lookup Table , 1986 .

[14]  Soon Heung Chang,et al.  Assessment of a tube-based bundle CHF prediction method using a subchannel code , 1998 .

[15]  M. Lee A critical heat flux approach for square rod bundles using the 1995 Groeneveld CHF table and bundle data of heat transfer research facility , 2000 .

[16]  D. Drew,et al.  Application of general constitutive principles to the derivation of multidimensional two-phase flow equations , 1979 .

[17]  S. Sugawara Analytical Prediction of CHF by FIDAS Code Based on Three-Fluid and Film-Dryout Model , 1990 .

[18]  Y. Miyamoto,et al.  FIDAS: Detailed subchannel analysis code based on the three-fluid and three-field model , 1990 .

[19]  Sreenivas Jayanti,et al.  Prediction of dryout and post-dryout heat transfer at high pressures using a one-dimensional three-fluid model , 2004 .

[20]  V. P. Bobkov,et al.  Considerations in describing burnout in rod bundles , 1997 .

[21]  J. Würtz,et al.  An experimental and theoretical investigation of annular steam-water flow in tubes and annuli at 30 to 90 bar , 1978 .

[22]  T. Ikeda,et al.  Critical Power Analysis with Mechanistic Models for Nuclear Fuel Bundles, (I) , 2002 .

[23]  P. Knabe,et al.  Prediction of dryout performance for boiling water reactor fuel assemblies based on subchannel analysis with the rings code , 1995 .

[24]  F. Barre,et al.  Advanced numerical methods for thermalhydraulics , 1993 .