High-voltage rectifier of the Energy-2 generator for electromagnetic sounding and monitoring of earthquake source zones

The high-voltage rectifier is described developed for the Energy-2 generator, with a capacity of 200 kW in which a step-up power transformer is used as a converter. The Energy-2 generator is intended for solving problems of precision deep electromagnetic monitoring of seismoactive regions of the Earth’s crust to find earthquake precursors. Theoretical investigation and numerical simulation of the high-voltage rectifier are carried out and parameters of its elemental base are optimized. All the high-voltage rectifier components, heat sink, and forced cooling system were manufactured on the basis of the developed documentation. The high-voltage rectifier was successfully tested as part of the“Energy-2 generator in August 2009 during the “FENIKS-2009” experiment.