Control scheme of grid-connected inverter based on virtual circuit

Main control objectives of grid-connected inverters include making the current injected into the grid keep accordance to its setting value without deviation, minimizing the harmonic current injected into the grid, and providing the system with good stability. To take all these indicators into account, this paper proposes a virtual circuit structure control scheme for grid-connected inverters. Aiming at designing the structure of circuit directly, we combine the variation of parameters into the design of circuit structure, which enables we achieve the control objectives in an indirect way. Simulation and experiment verified that the designed grid-connected inverter can enable the steady-state error to be zero, restrain harmonic current, and maintain good stability.

[1]  G. Griva,et al.  Improved current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[2]  F. Profumo,et al.  Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame , 2005, IEEE Transactions on Power Electronics.

[3]  Zou Yun-ping Research on Grid Connection Converter of Three-phase Power Electronic Load , 2010 .

[4]  Zhang Xiao-wen Research on Z source based current hysteresis control used in photovoltaic grid-connected system , 2010 .

[5]  Zhang Zhongxiao,et al.  Fault Line Selection Algorithm in Small Current Grounding Systems Based on a Trous Algorithm , 2011 .

[6]  R. Iravani,et al.  A unified dynamic model and control for the voltage-sourced converter under unbalanced grid conditions , 2006, IEEE Transactions on Power Delivery.

[7]  Chen Chien-liang High performance LCL-based utility-interactive inverter design and parallel applications , 2010 .

[8]  Cao Renxian Strategy Design of Multiple Feedback Loop Control for Grid-connected Voltage Source Inverter with LCL Filter , 2011 .

[9]  Ma Yundong Three-level Grid Connected Inverter for Renewable Generation in Ideal Power Grid Condition , 2010 .

[10]  Reza Iravani,et al.  A unified dynamic model and control for the voltage-sourced converter under unbalanced grid conditions , 2006 .

[11]  Liu Shangwei Control Strategy for Grid-connected Inverter to Suppress Current Distortion Effected by Background Harmonics in Grid Voltage , 2011 .

[12]  Li Xiaohua,et al.  Analysis and Countermeasures for the Unbalance Problem of Multi-parallel Line on the Same Tower , 2010 .

[13]  Wu Wei-yang Research on Hysteresis-band Current Tracking Control of Grid-connected Inverter , 2006 .

[14]  Zhang Xian-fei Z-source three-phase grid-connected PV system based on current hysteresis control , 2010 .

[15]  Chen Zhongwei,et al.  Research on Control Strategy for Three-Phase Double Mode Inverter , 2012 .

[16]  Qiu Xiao-ming Study on control scheme based on new multi-level photovoltaic grid-connected inverter , 2012 .

[17]  Wang Siran Research on Repetitive Control Method Applied to Grid-connected Inverter With LCL Filter , 2010 .