A voltage-sag compensation scheme based on the concept of power quality control center

The role of the power quality control center (PQCC) in mitigating the impacts of voltage sags on sensitive loads is examined. The center consists of back-to-back power converters, a dc bus, and a fuel cell distributed generator (DG) connected to the dc bus. It is shown that the range of voltage sags the system can ride through is determined by the current rating of the PQCC input-side inverter. Therefore, a three-stage operation scheme is proposed to improve on the system voltage sag ride-through capability. Stage 1 functions by maintaining the dc-link voltage at the same level as that before the sag. The PQCC input-side inverter would be protected from overloading during sag mitigation. The fuel cell remains undisturbed under this stage. Stage 2 is designed for compensating more severe sags. The purpose of introducing this stage is to decrease the input-side current through reducing the active power supplied by the upstream system. This is achieved by reducing the dc-link voltage and forcing the fuel cell to supply the balance of the active power. It is shown that this strategy can compensate for a voltage deviation of up to approximately double that under Stage 1. For even more severe sags that cannot be compensated under Stage 2, the PQCC would reduce the dc-link voltage even further, such that the DG supplies the entire protected loads. Simulation results are used to illustrate the validity of the proposed control scheme.

[1]  A. Sannino,et al.  Overview of voltage sag mitigation , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[2]  S. S. Choi,et al.  Transformerless dynamic voltage restorer , 2002 .

[3]  R. Spee,et al.  Voltage sag ride-through for adjustable speed drives with active rectifiers , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[4]  L. Kojovic,et al.  Application of current limiting fuses in distribution systems for improved power quality and protection , 1997 .

[5]  G. Strbac,et al.  Effects of small embedded generation on power quality , 1995 .

[6]  A. Hagiwara FUEL CELL SYSTEMS , 2022 .

[7]  R. Wu,et al.  Analysis of an AC to DC voltage source converter using PWM with phase and amplitude control , 1989, Conference Record of the IEEE Industry Applications Society Annual Meeting,.

[8]  Mariusz Malinowski,et al.  A comparative study of control techniques for PWM rectifiers in AC adjustable speed drives , 2003 .

[9]  Narain G. Hingorani,et al.  Introducing custom power , 1995 .

[10]  A. Mansoor,et al.  Effects of voltage sags on AC motor drives , 1997, 1997 IEEE Annual Textile, Fiber and Film Industry Technical Conference.

[11]  John D'Azzo,et al.  Linear Control System Analysis and Design: Conventional and Modern , 1977 .

[12]  Seung-Ki Sul,et al.  A novel ride-through system for adjustable speed drives using common-mode voltage , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[13]  J. R. McDonald,et al.  An integrated SOFC plant dynamic model for power systems simulation , 2000 .

[14]  M.P. Kazmierkowski,et al.  A comparative study of control techniques for PWM rectifiers in AC adjustable speed drives , 2001, IECON'01. 27th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.37243).