Overview of micromachined platforms for thermal sensing and gas detection

Micromachined hotplates, membranes, filaments, and cantilevers have all been used as platforms for thermal sensing and gas detection. Compared with conventional devices, micromachined sensors are characterized by low power consumption, high sensitivity, and fast response time. Much of these gains can be attributed to the size reductions achieved by micromachining. In addition, micromachining permits easy, yet precise tailoring of the heat transfer characteristics of these devices. By simple alterations in device geometry and materials used, the relative magnitudes of radiation, convection and conduction losses and Joule heat gains can be adjusted, and in this way device response can be optimized for specific applications. The free- standing design of micromachined platforms, for example, reduces heat conduction losses to the substrate, thereby making them attractive as low-power, fast-response heaters suitable for a number of applications. However, while micromachining solves some of the heat transfer problems typical of conventionally produced devices, it introduces some of its own. These trade-offs will be discussed in the context of several micromachined thermal and gas sensors described in the literature. These include micromachined flow sensors, gas thermal conductivity sensors, pressure sensors, uncooled IR sensors, metal-oxide and catalytic/calorimetric gas sensors. Recent results obtained for a microbridge-based catalytic/calorimetric gas sensor will also be presented as a means of further illustrating the concepts of thermal design in micromachined sensors.

[1]  T. A. Jones,et al.  The principles of the detection of flammable atmospheres by catalytic devices , 1973 .

[2]  M. Gall,et al.  Investigation of gas mixtures with different MOS gas sensors with regard to pattern recognition , 1989 .

[3]  C. Liu,et al.  A thick-film calormetric sensor for monitoring the concentration of combustible gases , 1989 .

[4]  M. G. Jones,et al.  The detection of hydrogen using catalytic flammable gas sensors , 1989 .

[5]  Isabelle Zdanevitch,et al.  Catalytic oxidation of methane on platinum thin films , 1992 .

[6]  A. Grisel,et al.  A low power integrated catalytic gas sensor , 1993 .

[7]  J. Funk,et al.  Overall System Analysis Of A Cmos Thermal Converter , 1995, Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.

[8]  Dominique Rebière,et al.  Thick film pellistor array with a neural network post-treatment , 1995 .

[9]  Paul J. McWhorter,et al.  Embedded micromechanical devices for the monolithic integration of MEMS with CMOS , 1995, Proceedings of International Electron Devices Meeting.

[10]  C. Scheibe,et al.  Basic Micro Module For Chemical Sensors With On Chip Heater And Buried Sensor Structure , 1995, Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.

[11]  U. Bonne,et al.  Fabrication and properties of a Si-based high-sensitivity microcalorimetric gas sensor , 1995 .

[12]  Julian W. Gardner,et al.  Intelligent gas sensing using an integrated sensor pair , 1995 .

[13]  John S. Suehle,et al.  Selected-area Deposition Of Multiple Active Films For Conductometric Microsensor Arrays , 1995, Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.

[14]  Robert Aigner,et al.  Si-planar-pellistor: Designs For Temperature Modulated Operation , 1995, Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95.

[15]  U. Lampe,et al.  Metal Oxide Sensors , 1995, International Conference on Solid-State Sensors, Actuators and Microsystems.