A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy.

PURPOSE To develop a hybrid approach to reduce computed tomography (CT) metal artifacts caused by the Fletcher-Suit applicator. METHODS AND MATERIALS Using the acquired raw projection data, the hybrid algorithm determines the separate contributions from the metal and non-metal objects. Next, reconstructions of metal and non-metal images are separately obtained from their estimated projections. A final image is formed by appropriately combining the individual images. Phantom and patient data are used to evaluate the performance of this method. RESULTS CT images reconstructed by use of the standard filtered-backprojection (FBP) algorithm contain significant artifacts even for small metal objects. However, images reconstructed using the hybrid algorithm contain virtually no artifacts. For metal objects with complex structures, the hybrid algorithm can also yield images containing fewer severe streak artifacts than those reconstructed using the FBP algorithm alone. CONCLUSIONS These studies demonstrate that the hybrid approach can effectively reduce CT metal artifacts caused by the Fletcher-Suit applicator.

[1]  C C Ling,et al.  CT-assisted assessment of bladder and rectum dose in gynecological implants. , 1987, International journal of radiation oncology, biology, physics.

[2]  Patrick Dupont,et al.  An iterative maximum-likelihood polychromatic algorithm for CT , 2001, IEEE Transactions on Medical Imaging.

[3]  Xiaochuan Pan,et al.  Reduction of computed tomography metal artifacts due to the Fletcher-Suit applicator in gynecology patients receiving intracavitary brachytherapy. , 2003, Brachytherapy.

[4]  W. Sewchand,et al.  Value of multi-planar CT images in interactive dosimetry planning of intracavitary therapy. , 1982, International journal of radiation oncology, biology, physics.

[5]  S L Schoeppel,et al.  Magnetic resonance imaging during intracavitary gynecologic brachytherapy. , 1992, International journal of radiation oncology, biology, physics.

[6]  K. Weeks,et al.  Dose calculation and measurements for a CT compatible version of the Fletcher applicator. , 1990, International journal of radiation oncology, biology, physics.

[7]  S L Schoeppel,et al.  Three-dimensional treatment planning of intracavitary gynecologic implants: analysis of ten cases and implications for dose specification. , 1994, International journal of radiation oncology, biology, physics.

[8]  Sasa Mutic,et al.  Physiologic FDG-PET three-dimensional brachytherapy treatment planning for cervical cancer. , 2002, International journal of radiation oncology, biology, physics.

[9]  G. Montana,et al.  Three-dimensional applicator system for carcinoma of the uterine cervix. , 1997, International journal of radiation oncology, biology, physics.

[10]  Joseph A. O'Sullivan,et al.  Iterative deblurring for CT metal artifact reduction , 1996, IEEE Trans. Medical Imaging.

[11]  Xiaochuan Pan,et al.  Optimal noise control in and fast reconstruction of fan-beam computed tomography image. , 1999, Medical physics.

[12]  D. McShan,et al.  A CT-compatible version of the Fletcher system intracavitary applicator: clinical application and 3-dimensional treatment planning. , 1989, International journal of radiation oncology, biology, physics.

[13]  Gary H. Glover,et al.  An algorithm for the reduction of metal clip artifacts in CT reconstructions. , 1981 .

[14]  A. Mundt,et al.  Race and clinical outcome in patients with carcinoma of the uterine cervix treated with radiation therapy. , 1998, Gynecologic oncology.

[15]  Silvia D. Chang,et al.  Proposed guidelines for image-based intracavitary brachytherapy for cervical carcinoma: report from Image-Guided Brachytherapy Working Group. , 2004, International journal of radiation oncology, biology, physics.

[16]  W. Kalender,et al.  Reduction of CT artifacts caused by metallic implants. , 1987 .