Effect of fiber orientation on the structural behavior of FRP wrapped concrete cylinders

In this study, 27 concrete cylinders with a diameter of 152.4 and a height of 304.8 mm were prepared. Among them, 18 cylinders were wrapped using two layers of fiber reinforced polymer (FRP) with six fiber orientations; six cylinders were wrapped using four layers of FRP with fibers in axial or hoop direction only; the remaining three cylinders were used as control. The FRP used was E-glass fiber reinforced ultraviolet (UV) curing vinyl ester. Fifteen coupon specimens were prepared to experimentally determine the tensile strength of the FRP with fibers oriented at 0°, 45°, and 90° from the loading direction. Co-axial compression tests were conducted on the wrapped cylinders and control cylinders. The test results were compared with existing confinement models. It is found that the strength, ductility, and failure mode of FRP wrapped concrete cylinders depend on the fiber orientation and wall thickness. Fibers oriented at a certain angle in between the hoop direction and axial direction may result in strength lower than fibers along hoop or axial direction. A larger database is desired in order to refine the existing design-oriented confinement models.

[1]  Amir Mirmiran,et al.  Behavior of Concrete Columns Confined by Fiber Composites , 1997 .

[2]  Elisa D. Sotelino,et al.  Strength estimation for FRP wrapped reinforced concrete columns , 2002 .

[3]  V. Karbhari,et al.  COMPOSITE JACKETED CONCRETE UNDER UNIAXIAL COMPRESSION--VERIFICATION OF SIMPLE DESIGN EQUATIONS , 1997 .

[4]  J. Teng,et al.  Strength Models for Fiber-Reinforced Plastic-Confined Concrete , 2002 .

[5]  Huei-Jeng Lin,et al.  Compressive strength of reinforced concrete column confined by composite material , 2004 .

[6]  Amir Mirmiran,et al.  Model of Concrete Confined by Fiber Composites , 1998 .

[7]  J. Teng,et al.  Design-oriented stress–strain model for FRP-confined concrete , 2003 .

[8]  Richard Sause,et al.  Axial Behavior of Reinforced Concrete Columns Confined with FRP Jackets , 2001 .

[9]  Taketo Uomoto,et al.  Use of Fiber Reinforced Polymer Composites as Reinforcing Material for Concrete , 2002 .

[10]  J. Mander,et al.  Theoretical stress strain model for confined concrete , 1988 .

[11]  Su-Seng Pang,et al.  Investigation into FRP repaired RC columns , 2003 .

[12]  Sami H. Rizkalla,et al.  Behavior of Axially Loaded Concrete-Filled Circular Fiber-Reinforced Polymer Tubes , 2001 .

[13]  A. Machida,et al.  Fiber-Reinforced Polymer Composites for Construction—State-of-the-Art Review , 2002 .

[14]  L. C. Hollaway,et al.  The evolution of and the way forward for advanced polymer composites in the civil infrastructure , 2003 .

[15]  Su-Seng Pang,et al.  Repair of damaged RC columns using fast curing FRP composites , 2003 .

[16]  F. E. Richart,et al.  A study of the failure of concrete under combined compressive stresses , 1928 .

[17]  M. R. Spoelstra,et al.  FRP-Confined Concrete Model , 2001 .

[18]  M. Fardis,et al.  FRP-encased concrete as a structural material , 1982 .

[19]  Miguel A. Pando,et al.  Precast piles for Route 40 bridge in Virginia using concrete filled FRP tubes , 2003 .

[20]  Julio F. Davalos,et al.  World Survey of Civil Engineering Programs on Fiber Reinforced Polymer Composites for Construction , 2003 .

[21]  Pierre Labossière,et al.  Axial Testing of Rectangular Column Models Confined with Composites , 2000 .

[22]  M. Saafi Design and Fabrication of FRP Grids for Aerospace and Civil Engineering Applications , 2000 .

[23]  Walid R. Alaywan,et al.  Experimental Study of FRP Tube-encased Concrete Columns , 2005 .

[24]  Patrick Paultre,et al.  Stress-Strain Model for Confined High-Strength Concrete , 1995 .

[25]  H. Toutanji STRESS-STRAIN CHARACTERISTICS OF CONCRETE COLUMNS EXTERNALLY CONFINED WITH ADVANCED FIBER COMPOSITE SHEETS , 1999 .