Double-step registration of in vivo stereophotogrammetry with both in vitro 6-DOFs electrogoniometry and CT medical imaging.

Standard registration techniques of bone morphology to motion analysis data often lead to unsatisfactory motion simulation because of discrepancies during the location of anatomical landmarks in the datasets. This paper describes an iterative registration method of a three-dimensional (3D) skeletal model with both 6 degrees-of-freedom joint kinematics and standard motion analysis data. The method is demonstrated in this paper on the lower limb. The method includes two steps. A primary registration allowed synchronization of in vitro kinematics of the knee and ankle joints using flexion/extension angles from in vivo gait analysis. Results from primary registration were then improved by a so-called advanced registration, which integrated external constraints obtained from experimental gait pre-knowledge. One cadaver specimen was analyzed to obtain both joint kinematics of knee and ankle joints using 3D electrogoniometry, and 3D bone morphology from medical imaging data. These data were registered with motion analysis data from a volunteer during the execution of locomotor tasks. Computer graphics output was implemented to visualize the results for a motion of sitting on a chair. Final registration results allowed the observation of both in vivo motion data and joint kinematics from the synchronized specimen data. The method improved interpretation of gait analysis data, thanks to the combination of realistic 3D bone models and joint mechanism. This method should be of interest both for research in gait analysis and medical education. Validation of the overall method was performed using RMS of the differences between bone poses estimated after registration and original data from motion analysis.

[1]  Bryan Buchholz,et al.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.

[2]  A. Leardini,et al.  Review: Diarthrodial Joints-Kinematic Pairs, Mechanisms or Flexible Structures? , 1998, Computer methods in biomechanics and biomedical engineering.

[3]  J. O'Connor,et al.  The components of passive knee movement are coupled to flexion angle. , 2000, Journal of biomechanics.

[4]  S. Jan,et al.  Analysis of helical axes, pivot and envelope in active wrist circumduction. , 2000, Clinical biomechanics.

[5]  Patrick Salvia,et al.  A new approach for the analysis and simulation of joint kinematics: Combining 3D-electrogoniometry data with medical imaging , 1999 .

[6]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[7]  Carl de Boor,et al.  A Practical Guide to Splines , 1978, Applied Mathematical Sciences.

[8]  J. O'Connor,et al.  Ligaments and articular contact guide passive knee flexion. , 1998, Journal of biomechanics.

[9]  H. Jacob,et al.  The mobility of the sacroiliac joint in healthy subjects. , 1996, Bulletin (Hospital for Joint Diseases (New York, N.Y.)).

[10]  J. O'Connor,et al.  Kinematics of the human ankle complex in passive flexion; a single degree of freedom system. , 1999, Journal of biomechanics.

[11]  Patrick Salvia,et al.  P063 Combination of both 3D electrogoniometry and medical imaging for joint kinematics visualization , 1998 .

[12]  Dan K Ramsey,et al.  Biomechanics of the knee: methodological considerations in the in vivo kinematic analysis of the tibiofemoral and patellofemoral joint. , 1999, Clinical biomechanics.

[13]  I Söderkvist,et al.  Determining the movements of the skeleton using well-configured markers. , 1993, Journal of biomechanics.

[14]  L Blankevoort,et al.  Helical axes of passive knee joint motions. , 1990, Journal of biomechanics.

[15]  J. O'Connor,et al.  A geometric model of the human ankle joint. , 1999, Journal of biomechanics.

[16]  Victor Sholukha,et al.  Development of multimedia learning modules for teaching human anatomy: application to osteology and functional anatomy. , 2003, Anatomical record. Part B, New anatomist.

[17]  A Leardini,et al.  Position and orientation in space of bones during movement: anatomical frame definition and determination. , 1995, Clinical biomechanics.

[18]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[19]  S. Van Sint Jan,et al.  Joint kinematics simulation from medical imaging data , 1997, IEEE Transactions on Biomedical Engineering.

[20]  T Leo AIM Project A2002: CAMARC-II (computer aided movement analysis in a rehabilitation context-II). , 1994, Computer methods and programs in biomedicine.

[21]  Victor Sholukha,et al.  Advanced modelling and simulation of the lower limb using medical imaging, electrogoniometry and gait analysis data , 2002 .

[22]  H. Woltring 3-D attitude representation of human joints: a standardization proposal. , 1994, Journal of biomechanics.

[23]  Victor Sholukha,et al.  Data representation for joint kinematics simulation of the lower limb within an educational context. , 2003, Medical engineering & physics.

[24]  S Van Sint Jan,et al.  Registration of 6-DOFs electrogoniometry and CT medical imaging for 3D joint modeling. , 2002, Journal of biomechanics.

[25]  A. Leardini,et al.  Data management in gait analysis for clinical applications. , 1998, Clinical biomechanics.

[26]  R J Belsole,et al.  Mathematical analysis of computed carpal models , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[27]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[28]  Véronique Feipel,et al.  Supplementary report on anatomical landmark definition , 2001 .

[29]  L P Nolte,et al.  Animation of in vitro biomechanical tests. , 2001, Journal of biomechanics.

[30]  Victor Sholukha,et al.  Calibration and validation of 6 DOFs instrumented spatial linkage for biomechanical applications. A practical approach. , 2004, Medical engineering & physics.

[31]  R. Fletcher Practical Methods of Optimization , 1988 .

[32]  J. Crisco,et al.  Noninvasive technique for measuring in vivo three‐dimensional carpal bone kinematics , 1999, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[33]  A. V. Zinkovsky,et al.  Mathematical Modelling and Computer Simulation of Biomechanical Systems , 1996 .

[34]  L. Blankevoort,et al.  The envelope of passive knee joint motion. , 1988, Journal of biomechanics.