Sub-ppb detection of formaldehyde with cantilever enhanced photoacoustic spectroscopy using quantum cascade laser source

A novel cantilever enhanced photoacoustic spectrometer with mid-infrared quantum cascade laser was applied for selective and sensitive formaldehyde (CH2O) gas measurement. The spectrum of formaldehyde was measured from 1,772 to 1,777 cm−1 by tuning the laser with a spectral resolution of 0.018 cm−1. The band at 1,773.959 cm−1 was selected for data analysis, at which position the laser emitted 47 mW. In univariate measurement, the detection limit (3σ, 0.951 s) and the normalized noise equivalent absorption coefficient (3σ) for amplitude modulation (AM) were 1.6 ppbv and 7.32 × 10−10 W cm−1 (Hz)−1/2 and for wavelength modulation (WM) 1.3 ppbv and 6.04 × 10−10 W cm−1 (Hz)−1/2. In multivariate measurement, the detection limit (3σ) can be as low as 901 pptv (1,773.833–1,774.085 cm−1, 15 spectral points each 0.951 s) for AM and 623 pptv (1,773.743–1,774.265 cm−1, 30 spectral points each 0.951 s) for WM. Because measurement time increases in multivariate measurement, its application is justified only when interferents need to be resolved. Potential improvements of the system are discussed.

[1]  Jyrki Kauppinen,et al.  Extremely sensitive CWA analyzer based on a novel optical pressure sensor in photoacoustic gas analysis , 2004, SPIE Security + Defence.

[2]  R. Marbach A New Method for Multivariate Calibration , 2005 .

[3]  V. Koskinen,et al.  Cantilever-based photoacoustic detection of carbon dioxide using a fiber-amplified diode laser , 2006 .

[4]  Tobias Gensty,et al.  Semiclassical model for the relative intensity noise of intersubband quantum cascade lasers , 2005 .

[5]  Vincenzo Spagnolo,et al.  Quantum Cascade Laser-Based Photoacoustic Sensor for Trace Detection of Formaldehyde Gas , 2009, Sensors.

[6]  Rui Q. Yang,et al.  Formaldehyde sensor using interband cascade laser based quartz-enhanced photoacoustic spectroscopy , 2004 .

[7]  M. Angelmahr,et al.  Photoacoustic spectroscopy of formaldehyde with tunable laser radiation at the parts per billion level , 2006 .

[8]  J. Uotila A new design of the differential photoacoustic gas detector combined with a cantilever microphone , 2008 .

[9]  T. Iguchi Modulation waveforms for second-harmonic detection with tunable diode lasers , 1986 .

[10]  Juho Uotila,et al.  Comparison of infrared sources for a differential photoacoustic gas detection system , 2007 .

[11]  R. Lehnen,et al.  Formaldehyde-related health complaints of residents living in mobile and conventional homes. , 1987, American journal of public health.

[12]  Juho Uotila,et al.  Fourier Transform Infrared Photoacoustic Multicomponent Gas Spectroscopy with Optical Cantilever Detection , 2010, Applied spectroscopy.

[13]  Jyrki Kauppinen,et al.  Photoacoustic Gas Analysis Using Interferometric Cantilever Microphone , 2007 .

[14]  A. Kodama,et al.  Respiratory health of plywood workers occupationally exposed to formaldehyde. , 1990, Archives of environmental health.

[15]  Jyrki Kauppinen,et al.  Selective differential photoacoustic method for trace gas analysis , 2005 .

[16]  Anton Amann,et al.  Lung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas , 2007 .

[17]  Sensitive and Fast Gas Sensor for Wide Variety of Applications Based on Novel Differential Infrared Photoacoustic Principle , 2012 .

[18]  J. Uotila Use of the Optical Cantilever Microphone in Photoacoustic Spectroscopy , 2009 .

[19]  J. Cihelka,et al.  Laser diode photoacoustic and FTIR laser spectroscopy of formaldehyde in the 2.3 μm and 3.5 μm spectral range , 2009 .

[20]  K. Roth,et al.  Dual cantilever enhanced photoacoustic detector with pulsed broadband IR-source , 2009 .

[21]  Fourier Transform Infrared Measurement of Solid-, Liquid-, and Gas-Phase Samples with a Single Photoacoustic Cell , 2008, Applied spectroscopy.

[22]  Jyrki Kauppinen,et al.  Optimization of a Microphone for Photoacoustic Spectroscopy , 2003, Applied spectroscopy.

[23]  Chuji Wang,et al.  Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits , 2009, Sensors.

[24]  Ralf Marbach,et al.  FT-IR-cPAS—New Photoacoustic Measurement Technique for Analysis of Hot Gases: A Case Study on VOCs , 2011, Sensors.

[25]  V. Koskinen,et al.  High sensitivity in gas analysis with photoacoustic detection , 2004 .

[26]  Jyrki Kauppinen,et al.  Extremely sensitive trace gas analysis with modern photoacoustic spectroscopy , 2006 .

[27]  R. Hernberg,et al.  Photoacoustic detection of oxygen using cantilever enhanced technique , 2006 .

[28]  A. Parkes,et al.  A sensitivity comparison of three photoacoustic cells containing a single microphone, a differential dual microphone or a cantilever pressure sensor , 2007 .

[29]  Ralf Marbach,et al.  On Wiener filtering and the physics behind statistical modeling. , 2002, Journal of biomedical optics.

[30]  R. Switzer,et al.  Integrated Evaluation of Central Nervous System Lesions: Stains for Neurons, Astrocytes, and Microglia Reveal the Spatial and Temporal Features of MK-801-induced Neuronal Necrosis in the Rat Cerebral Cortex , 1996, Toxicologic pathology.

[31]  V. Koskinen,et al.  Diode laser-based photoacoustic spectroscopy with interferometrically-enhanced cantilever detection: erratum. , 2006, Optics express.

[32]  V. Koskinen,et al.  Progress in cantilever enhanced photoacoustic spectroscopy , 2008 .

[33]  Kevin T. Morgan,et al.  Review Article: A Brief Review of Formaldehyde Carcinogenesis in Relation to Rat Nasal Pathology and Human Health Risk Assessment , 1997 .

[34]  K. Roth,et al.  Cantilever enhanced photoacoustic detection of carbon dioxide using a tunable diode laser source , 2007 .

[35]  Alistair M. Parkes,et al.  Trace gas detection using a novel cantilever-based photoacoustic spectrometer with multiplexed optical fiber-coupled diode lasers and fiber-amplification , 2007, SPIE Optics East.

[36]  Tom Kuusela,et al.  Photoacoustic gas detection using a cantilever microphone and III–V mid-IR LEDs , 2009 .

[37]  Wavelength modulation waveforms in laser photoacoustic spectroscopy. , 2009, Applied optics.

[38]  null null,et al.  Concise International Chemical Assessment Document , 2003 .