An integrated procedure to assess knee-joint kinematics and kinetics during gait using an optoelectric system and standardized X-rays.

This paper describes a 3-D gait analysis system, which combines optoelectric motion tracking and a standardized X-ray procedure, to calculate the net knee-joint forces and moments of a normal subject group during walking. The optoelectric system collects kinematic data from infra-red LED markers placed at selected skin surface locations and projecting probes attached to the lower limb. A standardized X-ray procedure is used to move surface markers into their designated bony landmarks based on individual bone structure, which reduces the error caused by uncertainty of skin-surface marker locations. Based on moved-in marker information, different joint coordinate systems are proposed for kinematic and kinetic analysis of the knee joint. Normalized data of knee angles, net reaction forces and net moments from 35 young, normal subjects are presented.

[1]  J G Andrews On the specification of joint configurations and motions. , 1984, Journal of biomechanics.

[2]  E. Chao,et al.  Justification of triaxial goniometer for the measurement of joint rotation. , 1980, Journal of biomechanics.

[3]  Mann Rw,et al.  Gait analysis--precise, rapid, automatic, 3-D position and orientation kinematics and dynamics. , 1983 .

[4]  J Isacson,et al.  Three-dimensional electrogoniometric gait recording. , 1986, Journal of biomechanics.

[5]  P R Cavanagh,et al.  Three-dimensional kinematics of the human knee during walking. , 1992, Journal of biomechanics.

[6]  J. Apkarian,et al.  A three-dimensional kinematic and dynamic model of the lower limb. , 1989, Journal of biomechanics.

[7]  R. Brand,et al.  The biomechanics and motor control of human gait: Normal, elderly, and pathological , 1992 .

[8]  B. Bresler The Forces and Moments in the Leg During Level Walking , 1950, Journal of Fluids Engineering.

[9]  U. P. Wyss,et al.  Three-dimensional knee joint reaction forces during walking and stair climbing , 1991 .

[10]  U P Wyss,et al.  A procedure to validate three-dimensional motion assessment systems. , 1993, Journal of biomechanics.

[11]  Harrington Ij,et al.  A bioengineering analysis of force actions at the knee in normal and pathological gait. , 1976 .

[12]  C. E. Clauser,et al.  Weight, volume, and center of mass of segments of the human body , 1969 .

[13]  G L Kinzel,et al.  Measurement of the total motion between two body segments. I. Analytical development. , 1972, Journal of biomechanics.

[14]  R. N. Stauffer,et al.  Normative data of knee joint motion and ground reaction forces in adult level walking. , 1983, Journal of biomechanics.

[15]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[16]  T D Cooke,et al.  A standardized technique for lower limb radiography. Practice, applications, and error analysis. , 1991, Investigative radiology.

[17]  Jb Morrison Bioengineering analysis of force actions transmitted by the knee joint , 1970 .

[18]  A. M. Mogilev,et al.  Selective intercommunication set for medical institutions , 1970 .

[19]  C D Mote,et al.  A finite helical axis as a landmark for kinematic reference of the knee. , 1991, Journal of biomechanical engineering.

[20]  D. Winter Biomechanical motor patterns in normal walking. , 1983, Journal of motor behavior.

[21]  T. P. Andriacchi,et al.  Three-Dimensional Coordinate Data Processing in Human Motion Analysis , 1979 .

[22]  M. Nietert,et al.  Das Kniegelenk des Menschen als biomechanisches Problem - The human knee-joint as a biomechanical problem , 1977 .

[23]  A Pedotti,et al.  A general computing method for the analysis of human locomotion. , 1975, Journal of biomechanics.

[24]  E. Chao,et al.  Application of optimization principles in determining the applied moments in human leg joints during gait. , 1973, Journal of biomechanics.

[25]  J B Morrison,et al.  The mechanics of the knee joint in relation to normal walking. , 1970, Journal of biomechanics.

[26]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[27]  T. Andriacchi,et al.  A study of lower-limb mechanics during stair-climbing. , 1980, The Journal of bone and joint surgery. American volume.

[28]  H. K. Ramakrishnan,et al.  Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[29]  D. Winter Biomechanics of Human Movement , 1980 .

[30]  G. R. Pennock,et al.  An anatomy-based coordinate system for the description of the kinematic displacements in the human knee. , 1990, Journal of biomechanics.

[31]  C. E. Clauser,et al.  Anthropometric Relationships of Body and Body Segment Moments of Inertia , 1980 .

[32]  R. J. Jefferson,et al.  Functional biomechanical assessment of the Oxford Meniscal Knee. , 1989, The Journal of arthroplasty.