Analytical methods and quality assurance

Abstract A wet digestion method of soil samples has been developed for analysis of “total” concentration (acid extraction) of elements by inductively coupled plasma emission spectrometry (ICP‐AES). This HNO3‐H2O2 wet digestion method is a simple, fast and safe sample preparation method with satisfactory accuracy and precision. The first examined condition was the applied digestion acid or acid mixture (HNO3, HNO3‐H2O2, HCl‐H2O2, HNO3‐HClO4, H2SO4‐H2O2), and the volume of concentrated nitric acid (65% HNO3). Temperature and duration of predigestion, volume of concentrated hydrogen‐peroxide (30 % H2O2), temperature and duration of digestion were also investigated. Two different kind of soil samples (a sandy soil with low humus content, calcareous chernozem with relatively high humus content), three different dry weight values and three different values for each parameters were chosen to investigate soil sample digestion in order to select the best parameters. A LABOR MIM Electronic Block Digest Apparatus was applied for sample preparation and numerous elements (e.g. Al, As, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, P, Pb, S, Sr, Zn) have been measured by a LABTAM 8440M Inductively Coupled Plasma Emission Spectrometer. The optimum values of parameters to digest soil sample in an electronic block digest apparatus are: a) 1 g dry weight, b) 5 cm3 HNO3 as digestion acid, c) 30°C‐60°C temperature range for 30–60 minutes predigestion, d) 5 cm3 30% H2O2, e) 120 C temperature for 270 minutes digestion. Two soil samples were digested with four methods (block digestion, Milestone microwave, Prolabo focused microwave and Hungarian standard). Results of the two microwaves and detailed block digestion methods are in well agreement in the two soil samples. Finally three Standard Reference Materials were applied to compare the appropriate results. These results showed well agreement for all elements except for aluminium and iron content. The difference between certified and measured results is dependent on their concentrations in soil.

[1]  J. Jones Soil test methods: Past, present, and future use of soil extractants , 1998 .

[2]  S. McGrath,et al.  Method to determine elemental sulphur in soils applied to measure sulphur oxidation , 1996 .

[3]  B. Kovács,et al.  A study of plant sample preparation and inductively coupled plasma emission spectrometry parameters , 1996 .

[4]  V. Chude,et al.  Hydrochloric acid (0.1M) and dtpa extractable and total iron and manganese in basaltic soil profiles of the Nigerian savanna , 1995 .

[5]  D. Grill,et al.  Determination of organic and inorganic sulphur by ion chromatography in small quantities of plant material , 1995 .

[6]  G. Lessman,et al.  An application of a modified microwave total dissolution technique for soils , 1995 .

[7]  H. Berndt,et al.  Sample introduction in ICP spectrometry by hydraulic high-pressure nebulization , 1994 .

[8]  J. Posta,et al.  High-performance flow flame atomic absorption spectrometry for automated on-line separation and determination of chromium(III)/chromium(VI) and preconcentration of chromium(VI) , 1993 .

[9]  H. Ajwa,et al.  Comparison of some methods for determination of sulfate in soils , 1993 .

[10]  F. Selles,et al.  Comparison of ion chromatography and a continuous‐flow technique for analysis of chloride and sulfate in plant samples , 1993 .

[11]  F. Pomares,et al.  Prediction of available heavy metals by six chemical extractants in a sewage sludge‐amended soil , 1991 .

[12]  R. Chaney,et al.  Residual heavy metal concentrations in sludge‐amended coastal plain soils ‐ I. Comparison of extractants , 1991 .

[13]  S. Goyal,et al.  Quantitative determination of total sulfur in plant tissues using acid digestion and ion-chromatography , 1991 .

[14]  B. Xing,et al.  Simple microwave digestion technique for elemental analysis of mineral soil samples. , 1990 .

[15]  J. Artiola,et al.  Determination of total sulfur in soil and plant samples using sodium bicarbonate/silver oxide, dry ashing and ion chromatography , 1990 .

[16]  M. V. Dael,et al.  Simultaneous determination of extractable sulphate and malate in plant extracts using ion chromatography , 1990 .

[17]  C. Reynolds,et al.  Dissolution of metals from soils and sediments with a microwave-nitric acid digestion technique. , 1990 .

[18]  P. D. Kluckner,et al.  Microwave digestion technique for the extraction of minerals from environmental marine sediments for analysis by inductively coupled plasma atomic emission spectrometry and atomic absorption spectrometry , 1989 .

[19]  S. Nam,et al.  Direct determination of chromium(III) and chromium(VI) with ion chromatography using direct current plasma emission as element-selective detector. , 1989, Journal of chromatographic science.

[20]  H. Kingston,et al.  Introduction to microwave sample preparation: theory and practice , 1988 .

[21]  D. Maynard,et al.  Extraction and determination of sulfur in organic horizons of forest soils , 1987 .

[22]  H. Kingston,et al.  Microwave energy for acid decomposition at elevated temperatures and pressures using biological and botanical samples. , 1986, Analytical chemistry.

[23]  B. Zarcinas,et al.  Nitric acid dissolution and multi‐element analysis of soils and sediments by inductively coupled plasma spectrometry , 1986 .

[24]  E. Schulte,et al.  Digestion of plant tissue for analysis by ICP emission spectroscopy , 1985 .

[25]  P. Lynch,et al.  Determination of exchangeable cations (Ca. Mg, Na, K) in aqueous and alcoholic NH4Cl extracts of soils using ICPES , 1985 .

[26]  R. Nadkarni Applications of microwave oven sample dissolution in analysis , 1984 .

[27]  R. Bruce,et al.  A comparison of methods for measuring Al, Ca, Mg in KC1 extracts of soils , 1984 .

[28]  S. R. Koirtyohann,et al.  Wet ashing of some biological samples in a microwave oven. , 1975, Analytical chemistry.

[29]  T. Gorsuch The destruction of organic matter , 1970 .