A comparison of radiation dose measured in CT dosimetry phantoms with calculations using EGS4 and voxel-based computational models.

CT is a high-dose examination and possibly the dominant contributor to dose from diagnostic radiology. Estimates of organ doses are obtained from Monte Carlo calculations and used to quantify radiation risk. To ensure the validity of using Monte Carlo calculations to estimate actual dose, measurements must be compared with calculations. We have measured doses to CT head and chest dosimetry phantoms and compared them with Monte Carlo (EGS4) calculated doses in voxel-based computational models of the phantoms. The simulation used an x-ray spectrum calculated from the specified values of the scanner's x-ray tube parameters. The scanner's beam-shaping filter was included in the modelling. Measured and calculated doses to both the head and chest phantoms agreed to within 7%. The inclusion of Rayleigh scattering in the calculations has a significant effect if only one slice is scanned but not if multiple slices are scanned.

[1]  An EGS4 based mathematical phantom for radiation protection calculations using standard man. , 1994, Health physics.

[2]  David W. O. Rogers,et al.  Presta: The parameter reduced electron-step transport algorithm for electron monte carlo transport , 1986 .

[3]  K. Nishizawa,et al.  Determinations of organ doses and effective dose equivalents from computed tomographic examination. , 1991, The British journal of radiology.

[4]  B. Wall,et al.  The Increasing Importance of X Ray Computed Tomography as a Source of Medical Exposure , 1995 .

[5]  J. H. Hubbell,et al.  Photon mass attenuation and energy-absorption coefficients , 1982 .

[6]  Marvin Rosenstein,et al.  Organ doses in diagnostic radiology , 1976 .

[7]  R. Cloutier Tissue Substitutes in Radiation Dosimetry and Measurement. , 1989 .

[8]  J. H. Hubbell,et al.  Photon mass attenuation and mass energy-absorption coefficients for H, C, N, O, Ar, and seven mixtures from 0.1 keV to 20 MeV. , 1977, Radiation research.

[9]  W. L. Dunn,et al.  A Monte Carlo model for absorbed dose calculations in computed tomography. , 1983, Medical physics.

[10]  Andreas Höfer,et al.  Ein Programm für die Berechnung von diagnostischen Röntgenspektren , 1985 .

[11]  D. G. Jones,et al.  Normalised Organ Doses for X Ray Computed Tomography Calculated Using Monte Carlo Techniques and a Mathematical Anthropomorphic Phantom , 1993 .

[12]  E. Vañó,et al.  A Comparison of Measured and Calculated Organ Doses from CT Examinations , 1995 .

[13]  M A Staniszewska A modification of Cristy's mathematical human phantoms for Monte carlo simulation , 1992 .

[14]  G Drexler,et al.  The construction of computer tomographic phantoms and their application in radiology and radiation protection , 1988, Radiation and environmental biophysics.

[15]  K Faulkner,et al.  Radiation Dose and Somatic Risk from Computed Tomography , 1987, Acta radiologica.