Faulted Phase Selection for Half-Wavelength Power Transmission Lines

In this paper, a novel faulted phase selection algorithm is proposed to be used for distance protection applied to half-wavelength power transmission lines. These lines represent an alternating current solution for very-long point-to-point interconnections as an alternative to HVDC. However, no such lines are currently in operation, and if this type of line is to be constructed, it will require its own protection philosophy because of its peculiar characteristics. This paper shows that the fault selection algorithms used in conventional relays do not work properly when applied to half-wavelength lines. The algorithm proposed herein is initially studied in the steady state and ultimately implemented in a programmable protective relay that is tested using a real-time simulator.

[1]  Renzo G. Fabián,et al.  Using of Conventional Relays for Protecting Half-Wavelength Transmission Line from Three-Phase Faults , 2013 .

[2]  W. Marsden I and J , 2012 .

[3]  Siemens Aktiengesellschaft,et al.  Numerical Distance Protection: Principles and Applications , 1999 .

[4]  V. K. Shcherbakov Power transmission over distances of 1500 to 3000 km , 1968 .

[5]  P. Strevens Iii , 1985 .

[6]  Ozenir Dias,et al.  Single-phase auto-reclosing mitigation procedure for half-wavelength transmission line , 2017 .

[7]  C. Portela,et al.  NON-CONVENTIONAL AC SOLUTIONS ADEQUATE FOR VERY LONG DISTANCE TRANSMISSION - AN ALTERNATIVE FOR THE AMAZON TRANSMISSION SYSTEM , 2007 .

[8]  S.F. Huang,et al.  A Distance Protection Relay for a 1000-kV UHV Transmission Line , 2008, IEEE Transactions on Power Delivery.

[9]  Walmir Freitas,et al.  Energization of a Half-Wavelength Transmission Line - Pre-Operational Transients Studies , 2013 .

[10]  Jing Ma,et al.  Electromagnetic transient analysis and novel protective relaying techniques for power transformer , 2014 .

[11]  J. Mahseredjian,et al.  A Combined Directional and Faulted Phase Selector Element Based on Incremental Quantities , 2001, IEEE Power Engineering Review.

[12]  David Costello,et al.  Determining the faulted phase , 2010, 2010 63rd Annual Conference for Protective Relay Engineers.

[13]  M.C. Tavares,et al.  Half-Wave Length Line Energization Case Test - Proposition of a Real Test , 2008, 2008 International Conference on High Voltage Engineering and Application.

[14]  F. J. Hubert,et al.  Half-wavelength power transmission lines , 1965 .

[15]  T. Einarsson,et al.  The Performance of Faulted Phase Selectors Used in Transmission Line Distance Applications , 2008, 2008 61st Annual Conference for Protective Relay Engineers.

[16]  T. Adu An Accurate Fault Classification Technique for Power System Monitoring Devices , 2002, IEEE Power Engineering Review.