1K versus 2K monitor: a clinical alternative free-response receiver operating characteristic study of observer performance using pulmonary nodules.

OBJECTIVE The aim of this study was to investigate whether and how observer performance in detecting pulmonary nodules is influenced by the use of 1K and 2K monitors with and without voluntary postprocessing. MATERIALS AND METHODS The study was conducted with clinical digital chest radiographs of 48 patients. CT images of the same patient group served as the gold standard. Data on four different monitor conditions (1K overview, 2K overview, 1K with postprocessing, and 2K with postprocessing) were collected using a 6-point confidence-rating scale and interpreted with an alternative free-response receiver operating characteristic. RESULTS When magnification and window settings were applied on the 1K monitor at the expense of an increased interpretation time, observer performance with the 1K monitor was not significantly different from that with the 2K monitor. A significant difference only occurred between the 1K monitor postprocessing condition and the 1K monitor overview condition. CONCLUSION Considering diagnostic accuracy, the 1K monitor is sufficient for the detection of pulmonary nodules, provided that postprocessing options--especially magnification--are applied. Further comparative monitor studies on the detectability of other abnormalities (e.g., fine interstitial structures) need to be performed.

[1]  D. Chakraborty,et al.  Free-response methodology: alternate analysis and a new observer-performance experiment. , 1990, Radiology.

[2]  D R Aberle,et al.  Comparison of 2048-line digital display formats and conventional radiographs: an ROC study. , 1989, AJR. American journal of roentgenology.

[3]  H E Rockette,et al.  Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images. , 1990, Radiology.

[4]  Hans M. Mosser,et al.  Clinical routine operation of a filmless radiology department: three years experience , 1995, Medical Imaging.

[5]  J. Bortz,et al.  Lehrbuch der empirischen Forschung , 1984 .

[6]  M. Jinzaki,et al.  Performance of Gd‐EOB‐DTPA and superparamagnetic iron oxide particles in the detection of primary liver cancer: A comparative study by alternative free‐response receiver operating characteristic analysis , 1997, Journal of magnetic resonance imaging : JMRI.

[7]  K. Doi,et al.  Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance. , 1986, Radiology.

[8]  J. Bloem,et al.  MR diagnosis of paraganglioma of the head and neck: value of contrast enhancement. , 1994, AJR. American journal of roentgenology.

[9]  D. Dorfman,et al.  Maximum-likelihood estimation of parameters of signal-detection theory and determination of confidence intervals—Rating-method data , 1969 .

[10]  J.-W. Oestmann,et al.  ROC: Methodik zum Vergleich der diagnostischen Leistung bildgebender Verfahren , 1989 .

[11]  E. Krupinski,et al.  Computer-displayed eye position as a visual aid to pulmonary nodule interpretation. , 1990, Investigative radiology.

[12]  R K Taira,et al.  Receiver-operating-characteristic study of chest radiographs in children: digital hard-copy film vs 2K x 2K soft-copy images. , 1992, AJR. American journal of roentgenology.

[13]  H L Kundel,et al.  Predictive value and threshold detectability of lung tumors. , 1981, Radiology.

[14]  E. Walter,et al.  Lienert, G. A.: Verteilungsfreie Methoden in der Biostatistik. Verlag Anton Hain, Meisenheim am Glan 1962; X + 361 S., DM 39,50 , 1964 .

[15]  D P Chakraborty,et al.  Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data. , 1989, Medical physics.

[16]  G. Lienert,et al.  Testaufbau und Testanalyse , 1962 .

[17]  Richard L. Morin,et al.  Mayo Clinic Jacksonville electronic radiology practice , 1996, Medical Imaging.