A 32-electrode data collection system for electrical impedance tomography

A 32-electrode data collection system for electrical impedance tomography (ETT) is presented. In this system, the demodulator is a multiplexed sample and hold (S&H) circuit followed by a voltage difference stage. This configuration provides high CMRR due to the low (almost DC) operating frequency of the signals the difference stage is required to process.<<ETX>>

[1]  B. M. Eyuboglu,et al.  In vivo imaging of cardiac related impedance changes , 1989, IEEE Engineering in Medicine and Biology Magazine.

[2]  P N Wells,et al.  A data collection system for gathering electrical impedance measurements from the human breast. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[3]  Willis J. Tompkins,et al.  Comparing Reconstruction Algorithms for Electrical Impedance Tomography , 1987, IEEE Transactions on Biomedical Engineering.

[4]  H W Woo,et al.  A prototype system and reconstruction algorithms for electrical impedance technique in medical body imaging. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[5]  George A. Kyriacou,et al.  A reconstruction algorithm of electrical impedance tomography with optimal configuration of the driven electrodes , 1993, IEEE Trans. Medical Imaging.

[6]  D C Barber,et al.  Theoretical limits to sensitivity and resolution in impedance imaging. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[7]  D C Barber,et al.  Electrical impedance imaging , 1987 .

[8]  Herbert Taub,et al.  Principles of communication systems , 1970 .

[9]  L Tarassenko,et al.  Impedance imaging in the newborn. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[10]  J.C. Newell,et al.  An electric current tomograph , 1988, IEEE Transactions on Biomedical Engineering.

[11]  H. Griffiths,et al.  Applied potential tomography for non-invasive temperature mapping in hyperthermia. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[12]  B H Brown,et al.  The Sheffield data collection system. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[13]  J Jossinet,et al.  Electrical Impedance Tomography - Applied Potential Tomography , 1988 .