Altered Flow Territories after Extracranial-Intracranial Bypass Surgery

OBJECTIVE: To prevent stroke after carotid sacrifice and to augment cerebral perfusion in patients with internal carotid artery (ICA) occlusion, high-flow extracranial-intracranial (EC-IC) bypass operations are performed. Although the function and efficacy of the bypass is monitored during surgery, the postoperative flow through the bypass is significantly lower than the flow in the contralateral ICA. Thus far, it is unknown whether decreased bypass flow is caused by a low tissue perfusion or by a relatively small flow territory. METHODS: Seven patients, four with an atherosclerotic ICA occlusion and three with a giant aneurysm of the ICA, were investigated; each underwent a high-flow EC-IC bypass and permanent occlusion of the ICA. Cerebral blood flow was measured with arterial spin labeling perfusion magnetic resonance imaging. Separate flow territory mapping of the EC-IC bypass, contralateral ICA, and posterior circulation was performed with selective arterial spin labeling magnetic resonance imaging. RESULTS: No significant difference was found in cerebral blood flow between the hemisphere ipsilateral to the EC-IC bypass (70.9 ± 11.3 ml/min/100 g tissue), contralateral to the EC-IC bypass (71.9 ± 14.3 ml/min/100 g tissue), and comparable findings in 50 healthy control participants (69.1 ± 17.5 ml/min/100 g tissue). Paired analysis of the individual flow territories demonstrated a 15% volume reduction (P = 0.018) in flow territory of the EC-IC bypass compared with the contralateral side. CONCLUSION: In the present study, we demonstrate the feasibility of selective arterial spin labeling magnetic resonance imaging for clinical follow-up of patients after high-flow EC/IC bypass surgery, providing both information on flow territories and the level of regional cerebral blood flow.

[1]  T. Iwama,et al.  Improvement of oxygen metabolic reserve after extracranial-intracranial bypass surgery in patients with severe haemodynamic insufficiency , 2005, Acta Neurochirurgica.

[2]  Jeroen van der Grond,et al.  Flow Territory Mapping of the Cerebral Arteries With Regional Perfusion MRI , 2004, Stroke.

[3]  A. Casasco,et al.  Balloon occlusion of the internal carotid artery in 40 cases of giant intracavernous aneurysm: technical aspects, cerebral monitoring, and results , 2004, Neuroradiology.

[4]  Albert van der Zwan,et al.  Anatomy and Functionality of Leptomeningeal Anastomoses: A Review , 2003, Stroke.

[5]  A. van der Zwan,et al.  Hemodynamic Compensation via an Excimer Laser-assisted, High-flow Bypass before and after Therapeutic Occlusion of the Internal Carotid Artery , 2003, Neurosurgery.

[6]  Jeroen van der Grond,et al.  Measurements of cerebral perfusion and arterial hemodynamics during visual stimulation using TURBO‐TILT , 2003, Magnetic resonance in medicine.

[7]  A. Algra,et al.  Excimer laser-assisted bypass in aneurysm treatment: short-term outcomes. , 2002, Journal of neurosurgery.

[8]  A. van der Zwan,et al.  Excimer Laser–Assisted High-Flow Extracranial/Intracranial Bypass in Patients With Symptomatic Carotid Artery Occlusion at High Risk of Recurrent Cerebral Ischemia: Safety and Long-Term Outcome , 2002, Stroke.

[9]  W. Young,et al.  Clinical Utility of Quantitative Cerebral Blood Flow Measurements during Internal Carotid Artery Test Occlusions , 2002, Neurosurgery.

[10]  Michael Bock,et al.  Arterial spin labeling in combination with a look‐locker sampling strategy: Inflow turbo‐sampling EPI‐FAIR (ITS‐FAIR) , 2001, Magnetic resonance in medicine.

[11]  G. Cantore,et al.  Cerebral hemodynamics on MR perfusion images before and after bypass surgery in patients with giant intracranial aneurysms. , 2001, AJNR. American journal of neuroradiology.

[12]  C. Tulleken Carotid balloon occlusion for large and giant aneurysms: evaluation of a new test occlusion protocol. , 2001, Neurosurgery.

[13]  R. Grubb,et al.  Preview of a new trial of extracranial-to-intracranial arterial anastomosis: the carotid occlusion surgery study. , 2001, Neurosurgery clinics of North America.

[14]  W. Young,et al.  Recovery of brain function during induced cerebral hypoperfusion. , 2001, Brain : a journal of neurology.

[15]  T. Iwama,et al.  Cerebral Hemodynamic Parameters for Patients with Neurological Improvements after Extracranial-Intracranial Arterial Bypass Surgery: Evaluation Using Positron Emission Tomography , 2001, Neurosurgery.

[16]  A. van der Zwan,et al.  Flow Quantification of the Non-Occlusive Excimer Laser-Assisted EC-IC Bypass , 2001, Acta Neurochirurgica.

[17]  Jeff Duyn,et al.  H215O PET validation of steady‐state arterial spin tagging cerebral blood flow measurements in humans , 2000, Magnetic resonance in medicine.

[18]  G. Joseph,et al.  Prevention of complications resulting from endovascular carotid sacrifice: a retrospective assessment. , 2000, Neurosurgery.

[19]  David L. Thomas,et al.  Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques , 1999, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[20]  J. Detre,et al.  Perfusion magnetic resonance imaging with continuous arterial spin labeling: methods and clinical applications in the central nervous system. , 1999, European journal of radiology.

[21]  P. Boesiger,et al.  Transfer insensitive labeling technique (TILT): Application to multislice functional perfusion imaging , 1999, Journal of magnetic resonance imaging : JMRI.

[22]  S Warach,et al.  A general kinetic model for quantitative perfusion imaging with arterial spin labeling , 1998, Magnetic resonance in medicine.

[23]  W. Mali,et al.  MRA flow quantification in patients with a symptomatic internal carotid artery occlusion. The Dutch EC-IC Bypass Study Group. , 1997, Stroke.

[24]  G. Wieneke,et al.  Bilateral increase in CO2 reactivity after unilateral carotid endarterectomy. , 1997, Stroke.

[25]  C. Tulleken,et al.  The modified excimer laser-assisted high-flow bypass operation. , 1996, Surgical neurology.

[26]  B. Hillen,et al.  Effects of anterior communicating artery diameter on cerebral hemodynamics in internal carotid artery disease. A model study. , 1995, Circulation.

[27]  H. Yonas,et al.  Stroke risk after abrupt internal carotid artery sacrifice: accuracy of preoperative assessment with balloon test occlusion and stable xenon-enhanced CT. , 1994, AJNR. American journal of neuroradiology.

[28]  M Dujovny,et al.  A Quantitative Investigation of the Variability of the Major Cerebral Arterial Territories , 1993, Stroke.

[29]  R. Verdaasdonk,et al.  Use of the excimer laser in high-flow bypass surgery of the brain. , 1993, Journal of neurosurgery.

[30]  M Dujovny,et al.  Variability of the territories of the major cerebral arteries. , 1992, Journal of neurosurgery.

[31]  R. Wise,et al.  Cerebral haemodynamic changes after extracranial-intracranial bypass surgery. , 1987, Journal of neurology, neurosurgery, and psychiatry.

[32]  D. Pelz,et al.  Use of detachable balloons for proximal artery occlusion in the treatment of unclippable cerebral aneurysms. , 1987, Journal of neurosurgery.

[33]  Lippincott Williams Wilkins,et al.  The International Cooperative Study of Extracranial/Intracranial Arterial Anastomosis (EC/IC Bypass Study): methodology and entry characteristics. The EC/IC Bypass Study group. , 1985, Stroke.

[34]  Failure of extracranial-intracranial arterial bypass to reduce the risk of ischemic stroke. Results of an international randomized trial. , 1985, The New England journal of medicine.

[35]  Y. Yonekawa,et al.  Results of microsurgical extra-intracranial arterial bypass in the treatment of cerebral ischemia. , 1977, Neurosurgery.