Piezoelectric Bimorphs' Characteristics as In-Socket Sensors for Transfemoral Amputees

Alternative sensory systems for the development of prosthetic knees are being increasingly highlighted nowadays, due to the rapid advancements in the field of lower limb prosthetics. This study presents the use of piezoelectric bimorphs as in-socket sensors for transfemoral amputees. An Instron machine was used in the calibration procedure and the corresponding output data were further analyzed to determine the static and dynamic characteristics of the piezoelectric bimorph. The piezoelectric bimorph showed appropriate static operating range, repeatability, hysteresis, and frequency response for application in lower prosthesis, with a force range of 0–100 N. To further validate this finding, an experiment was conducted with a single transfemoral amputee subject to measure the stump/socket pressure using the piezoelectric bimorph embedded inside the socket. The results showed that a maximum interface pressure of about 27 kPa occurred at the anterior proximal site compared to the anterior distal and posterior sites, consistent with values published in other studies. This paper highlighted the capacity of piezoelectric bimorphs to perform as in-socket sensors for transfemoral amputees. However, further experiments are recommended to be conducted with different amputees with different socket types.

[1]  R Jiménez-Fabián,et al.  Review of control algorithms for robotic ankle systems in lower-limb orthoses, prostheses, and exoskeletons. , 2012, Medical engineering & physics.

[2]  J. A. Florez,et al.  Calibration of force sensing resistors (fsr) for static and dynamic applications , 2010, 2010 IEEE ANDESCON.

[3]  Akio Nakagawa,et al.  Identification of pressure distribution at the socket interface of an above-knee prosthesis , 1997 .

[4]  Angus McFadyen,et al.  Dynamic interface pressure distributions of two transtibial prosthetic socket concepts. , 2009, Journal of rehabilitation research and development.

[5]  Liang Song,et al.  Development of an Intelligent Prosthetic Knee Control System , 2010, 2010 International Conference on Electrical and Control Engineering.

[6]  M. Mun,et al.  Relationship between socket pressure and EMG of two muscles in trans-femoral stumps during gait , 2005, Prosthetics and orthotics international.

[7]  Hugh Herr,et al.  User-adaptive control of a magnetorheological prosthetic knee , 2003, Ind. Robot.

[8]  Lingling Chen,et al.  Design and analysis of active transfemoral prosthesis , 2010, IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society.

[9]  He Huang,et al.  Integration of surface electromyographic sensors with the transfemoral amputee socket: A comparison of four differing configurations , 2015, Prosthetics and orthotics international.

[10]  Aiguo Song,et al.  A Robust Static Decoupling Algorithm for 3-Axis Force Sensors Based on Coupling Error Model and ε-SVR , 2012, Sensors.

[11]  Katsuhiko Ogata,et al.  Modern Control Engineering , 1970 .

[12]  Akin O. Kapti,et al.  Design and control of an active artificial knee joint , 2006 .

[13]  Xiangrong Shen,et al.  Electromyography-based control of active above-knee prostheses , 2011 .

[14]  Libin Zhang,et al.  Measurement Performance Assessment: Dynamic Calibration Compared with Static Calibration Method for Roller Tester of Vehicle Brake Force , 2014 .

[15]  Malte Bellmann,et al.  Comparative biomechanical analysis of current microprocessor-controlled prosthetic knee joints. , 2010, Archives of physical medicine and rehabilitation.

[16]  C. D. Hoover,et al.  Stair Ascent With a Powered Transfemoral Prosthesis Under Direct Myoelectric Control , 2013, IEEE/ASME Transactions on Mechatronics.

[17]  Yuansheng Chen,et al.  Modeling hysteresis and creep behavior of macrofiber composite–based piezoelectric bimorph actuator , 2013 .

[18]  H.A. Varol,et al.  Preliminary Evaluations of a Self-Contained Anthropomorphic Transfemoral Prosthesis , 2009, IEEE/ASME Transactions on Mechatronics.

[19]  W. Lee,et al.  Load transfer mechanics between trans-tibial prosthetic socket and residual limb--dynamic effects. , 2004, Journal of biomechanics.

[20]  Abbas Dehghani,et al.  Intelligent Prosthesis – a Biomechatronics Approach , 2010 .

[21]  Noor Azuan Abu Osman,et al.  Interface pressure in transtibial socket during ascent and descent on stairs and its effect on patient satisfaction. , 2013, Clinical biomechanics.

[22]  Minoru Taya,et al.  Design and fabrication of functionally graded PZT/Pt piezoelectric bimorph actuator , 2002 .

[23]  Mica Grujicic,et al.  Optimization of a piezoelectric bimorph grasper for use in minimally invasive surgical applications , 2005 .

[24]  V. Piefort FINITE ELEMENT MODELLING OF PIEZOELECTRIC ACTIVE STRUCTURES: SOME AP- PLICATIONS IN VIBROACOUSTICS , 2001 .

[25]  W D Spence,et al.  Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees—a preliminary study , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[26]  Wilmar Hernandez,et al.  Improving the Response of a Load Cell by Using Optimal Filtering , 2006, Sensors (Basel, Switzerland).

[27]  Nur Azah Hamzaid,et al.  Technology Efficacy in Active Prosthetic Knees for Transfemoral Amputees: A Quantitative Evaluation , 2014, TheScientificWorldJournal.

[28]  Marko Pudas,et al.  Piezoelectric bimorph charge mode force sensor , 2009 .

[29]  Lech Solarz,et al.  Surface Acoustic Wave (SAW) Vibration Sensors , 2011, Sensors.

[30]  Lu-Ping Chao,et al.  Shape optimal design and force sensitivity evaluation of six-axis force sensors , 1997 .

[31]  Dae-Hyun Kim,et al.  Parametric Study of the Reflective Periodic Grating for In-Plane Displacement Measurement Using Optical Fibers , 2012, Sensors.

[32]  A A Polliack,et al.  Scientific validation of two commercial pressure sensor systems for prosthetic socket fit , 2000, Prosthetics and orthotics international.

[33]  Nur Azah Hamzaid,et al.  Development of a Micro-Gripper Using Piezoelectric Bimorphs , 2013, Sensors.

[34]  R. Ballas,et al.  Piezoelectric Multilayer Beam-Bending Actuators: Static and Dynamic Behavior and Aspects of Sensor Integration (Microtechnology and MEMS) , 2007 .

[35]  Aiguo Song,et al.  A novel self-decoupled four degree-of-freedom wrist force/torque sensor , 2007 .