Design of a Collapse-Mode CMUT With an Embossed Membrane for Improving Output Pressure

Capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a competitive alternative to piezoelectric ultrasonic transducers, especially in medical ultrasound imaging and therapeutic ultrasound applications, which require high output pressure. However, as compared with piezoelectric ultrasonic transducers, the output pressure capability of CMUTs remains to be improved. In this paper, a novel structure is proposed by forming an embossed vibrating membrane on a CMUT cell operating in the collapse mode to increase the maximum output pressure. By using a beam model in undamped conditions and finite-element analysis simulations, the proposed embossed structure showed improvement on the maximum output pressure of the CMUT cell when the embossed pattern was placed on the estimated location of the peak deflection. As compared with a uniform membrane CMUT cell worked in the collapse mode, the proposed CMUT cell can yield the maximum output pressure by 51.1% and 88.1% enhancement with a single embossed pattern made of Si3N4 and nickel, respectively. The maximum output pressures were improved by 34.9% (a single Si3N4 embossed pattern) and 46.7% (a single nickel embossed pattern) with the uniform membrane when the center frequencies of both original and embossed CMUT designs were similar.

[1]  O. Oralkan,et al.  Capacitive micromachined ultrasonic transducer design for high power transmission , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[2]  D. Mills,et al.  Real-time in-vivo imaging with capacitive micromachined ultrasound transducer (cMUT) linear arrays , 2003, IEEE Symposium on Ultrasonics, 2003.

[3]  B.T. Khuri-Yakub,et al.  A new regime for operating capacitive micromachined ultrasonic transducers , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Ching-Hsiang Cheng,et al.  Comparison of conventional and collapsed region operation of capacitive micromachined ultrasonic transducers , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[5]  Cv Clemens Verhoosel,et al.  Non-Linear Finite Element Analysis of Solids and Structures , 1991 .

[6]  O. Oralkan,et al.  Volumetric ultrasound imaging using 2-D CMUT arrays , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[7]  D. T. Yeh,et al.  Experimental characterization of collapse-mode CMUT operation , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Mario Kupnik,et al.  Fabrication of CMUT Cells with Gold Center Mass for Higher Output Pressure , 2011 .

[9]  A. Atalar,et al.  Improved performance of cMUT with nonuniform membranes , 2005, IEEE Ultrasonics Symposium, 2005..

[10]  A. Atalar,et al.  Optimization of the gain-bandwidth product of capacitive micromachined ultrasonic transducers , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Kwan Kyu Park,et al.  A comparison between conventional and collapse-mode capacitive micromachined ultrasonic transducers in 10-MHz 1-D arrays , 2013, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[12]  B.T. Khuri-Yakub,et al.  Finite-element analysis of capacitive micromachined ultrasonic transducers , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  Abdullah Atalar,et al.  Parametric nonlinear lumped element model for circular CMUTs in collapsed mode , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[14]  H. Koymen,et al.  An equivalent circuit model for transmitting capacitive micromachined ultrasonic transducers in collapse mode , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  J. McLean,et al.  CMUTS with dual electrode structure for improved transmit and receive performance , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Vincenzo Ciampi,et al.  M. A. Crisfield, Non-linear Finite Element Analysis of Solids and Structures , 1997 .

[17]  J. L. Humar Dynamics of structures , 1990 .

[18]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  C Wykes,et al.  The performance of capacitive ultrasonic transducers using v-grooved backplates , 1991 .

[20]  A. Atalar,et al.  Deep-collapse operation of capacitive micromachined ultrasonic transducers , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  K. Suzuki,et al.  A silicon electrostatic ultrasonic transducer , 1989, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  O. Oralkan,et al.  Initial pulse-echo imaging results with one-dimensional capacitive micromachined ultrasonic transducer arrays , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[23]  Mario Kupnik,et al.  Capacitive Micromachined Ultrasonic Transducers for Therapeutic Ultrasound Applications , 2010, IEEE Transactions on Biomedical Engineering.

[24]  Yongli Huang,et al.  Capacitive micromachined ultrasonic transducers with piston-shaped membranes: fabrication and experimental characterization , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  Jørgen Arendt Jensen,et al.  Medical ultrasound imaging. , 2007, Progress in biophysics and molecular biology.