Calibrating and Validating the MFI-UF Method to Measure Particulate Fouling in Reverse Osmosis

This study aimed to calibrate and validate the MFI-UF method in order to ensure the accuracy of particulate fouling measurements in RO. Firstly, the MFI-UF calibration was examined using two solutions of standard particles (dextran and polystyrene). Two main criteria were investigated: (i) MFI-UF linearity with particle concentrations at both low and high ranges of fouling potential and (ii) the reproducibility of MFI-UF linearity. Dextran solutions showed a strong MFI-UF linearity over the entire range of measured MFI-UF. However, the linearity was not reproducible, and different batches of dextran prepared under the same conditions produced very variable results. For polystyrene solutions, the MFI-UF linearity was verified at the higher range of MFI-UF (>10,000 s/L2), while the MFI-UF at the lower range (<5000 s/L2) appeared to be underestimated. Secondly, MFI-UF linearity was investigated using natural (surface) water under a wide range of testing conditions (at 20–200 L/m2·h using 5–100 kDa membranes). Strong MFI-UF linearity was obtained over the entire range of measured MFI-UF (up to 70,000 s/L2). Thus, the MFI-UF method was validated to measure different levels of particulate fouling in RO. However, future research focusing on MFI-UF calibration is still required through the selection, preparation, and testing of heterogeneous mixtures of standard particles.

[1]  N. Ghaffour,et al.  Prediction of particulate fouling in full-scale reverse osmosis plants using the modified fouling index – ultrafiltration (MFI-UF) method , 2023, Desalination.

[2]  N. Ghaffour,et al.  Improving MFI-UF constant flux to more accurately predict particulate fouling in RO systems: Quantifying the effect of membrane surface porosity , 2022, Journal of Membrane Science.

[3]  Gary L. Amy,et al.  The Modified Fouling Index Ultrafiltration constant flux for assessing particulate/colloidal fouling of RO systems , 2015 .

[4]  G. Amy,et al.  Flux dependency of particulate/colloidal fouling in seawater reverse osmosis systems , 2012 .

[5]  S. Rodríguez Particulate and organic matter fouling of seawater reverse osmosis systems: Characterization, modelling and applications , 2011 .

[6]  D. Laskin,et al.  Threshold size for optimal passive pulmonary targeting and retention of rigid microparticles in rats. , 2010, Journal of controlled release : official journal of the Controlled Release Society.

[7]  Maria D. Kennedy,et al.  Development of the MFI-UF in constant flux filtration , 2004 .

[8]  Maria D. Kennedy,et al.  Applications of the MFI-UF to measure and predict particulate fouling in RO systems , 2003 .

[9]  Zeyad S. Tarawneh,et al.  The MFI-UF as a water quality test and monitor , 2003 .

[10]  Maria D. Kennedy,et al.  The modified fouling index using ultrafiltration membranes (MFI-UF): characterisation, filtration mechanisms and proposed reference membrane , 2002 .

[11]  Gilbert Galjaard,et al.  Monitoring particulate fouling in membrane systems , 1998 .

[12]  P.A.C. Bonné,et al.  Prediction of flux decline in membrane systems due to particulate fouling , 1997 .

[13]  J. Schippers,et al.  Reverse osmosis for treatment of surface water , 1985 .

[14]  J. C. Schippers,et al.  The modified fouling index, a method of determining the fouling characteristics of water , 1980 .