Characterisation of Morphic Sensors for Body Volume and Shape Applications

Stretchable conductive materials are originally conceived as radio frequency (RF) and electromagnetic interference (EMI) shielding materials, and, under stretch, they generally function as distributed strain-gauges. These commercially available conductive elastomers have found their space in low power health monitoring systems, for example, to monitor respiratory and cardiac functions. Conductive elastomers do not behave linearly due to material constraints; hence, when used as a sensor, a full characterisation to identify ideal operating ranges are required. In this paper, we studied how the continuous stretch cycles affected the material electrical and physical properties in different embodiment impressed by bodily volume change. We simulated the stretch associated with breathing using a bespoke stress rig to ensure reproducibility of results. The stretch rig is capable of providing constant sinusoidal waves in the physiological ranges of extension and frequency. The material performances is evaluated assessing the total harmonic distortion (THD), signal-to-noise ratio (SNR), correlation coefficient, peak to peak (P-P) amplitude, accuracy, repeatability, hysteresis, delay, and washability. The results showed that, among the three controlled variables, stretch length, stretch frequency and fabric width, the most significant factor to the signal quality is the stretch length. The ideal working region is within 2% of the original length. The material cut in strips of >3 mm show more reliable to handle a variety of stretch parameter without losing its internal characteristics and electrical properties.

[1]  C W Whitney,et al.  Sleep-disordered breathing and cardiovascular disease: cross-sectional results of the Sleep Heart Health Study. , 2001, American journal of respiratory and critical care medicine.

[2]  Juan Carlos,et al.  Sensor-Based Garments that Enable the Use of Bioimpedance Technology: Towards Personalized Healthcare Monitoring. , 2013 .

[3]  Colin M. Shapiro,et al.  STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea , 2008, Anesthesiology.

[4]  I. Park,et al.  Highly stretchable and sensitive strain sensor based on silver nanowire-elastomer nanocomposite. , 2014, ACS nano.

[5]  I. Park,et al.  Stretchable, Skin‐Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review , 2016 .

[6]  Gaetano D. Gargiulo,et al.  HeMo: Towards an inexpensive wearable peripheral blood flow monitoring device , 2015, 2015 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[7]  D. De Rossi,et al.  Advances in textile technologies for unobtrusive monitoring of vital parameters and movements , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[8]  T. Pellis,et al.  Cardiac Arrest and Cardiopulmonary Resuscitation: Starting from Basic Science and Bioengineering Research to Improve Resuscitation Outcome , 2014, BioMed research international.

[9]  AdrianJ Williams,et al.  Clinical value of polysomnography , 1992, The Lancet.

[10]  D. Shmilovitz,et al.  On the definition of total harmonic distortion and its effect on measurement interpretation , 2005, IEEE Transactions on Power Delivery.

[11]  Gaetano D. Gargiulo,et al.  Polymer sensor embedded, IOT enabled t-shirt for long-term monitoring of sleep disordered breathing , 2019, 2019 IEEE 5th World Forum on Internet of Things (WF-IoT).

[12]  Gaetano D Gargiulo,et al.  Electro-resistive bands for non-invasive cardiac and respiration monitoring, a feasibility study , 2015, Physiological measurement.

[13]  Paul Smeyers,et al.  Adults and children , 2007 .

[14]  Hisashi Adachi,et al.  Inflammation, atherosclerosis, and coronary artery disease. , 2005, The New England journal of medicine.

[15]  C. Majidi Soft Robotics: A Perspective—Current Trends and Prospects for the Future , 2014 .

[16]  Melvin D. Cheitlin Principles of Cardiac Arrhythmias. , 1973 .

[17]  Upul Gunawardana,et al.  A Wearable Contactless Sensor Suitable for Continuous Simultaneous Monitoring of Respiration and Cardiac Activity , 2015, J. Sensors.

[18]  MajidiCarmel,et al.  Soft Robotics: A Perspective—Current Trends and Prospects for the Future , 2014 .

[19]  P. Sly,et al.  Measurements of PEEP-induced changes in lung volume: evaluation of a laser monitor. , 1997, Chest.

[20]  G. Fonarow,et al.  Home monitoring for heart failure management. , 2012, Journal of the American College of Cardiology.

[21]  Mary M. Rodgers,et al.  Recent Advances in Wearable Sensors for Health Monitoring , 2015, IEEE Sensors Journal.

[22]  A. Gardner,et al.  Physical activity monitoring in patients with peripheral arterial occlusive disease. , 1997, Journal of cardiopulmonary rehabilitation.

[23]  R. Fernández-García,et al.  Crosstalk characterization of fabrics elaborated with conductive yarns , 2016, 2016 International Symposium on Electromagnetic Compatibility - EMC EUROPE.

[24]  Mamun Bin Ibne Reaz,et al.  Characterization of Textile-Insulated Capacitive Biosensors , 2017, Sensors.

[25]  D. De Rossi,et al.  Wearable, redundant fabric-based sensor arrays for reconstruction of body segment posture , 2004, IEEE Sensors Journal.

[26]  I. Masters,et al.  Measuring tidal volume and functional residual capacity change in sleeping infants using a volume displacement plethysmograph. , 1998, The European respiratory journal.

[27]  Juliane Junker,et al.  Medical Instrumentation Application And Design , 2016 .

[28]  Gaetano D. Gargiulo,et al.  Hemodynamic monitor for rapid, cost-effective assessment of peripheral vascular function , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[29]  D W Cartwright,et al.  A respiratory function jacket for measuring tidal volume and changes in FRC. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.