Part 1: Optimization and evaluation of dynamic trajectory radiotherapy

PURPOSE Although volumetric modulated arc therapy (VMAT) is a well-accepted treatment technique in radiotherapy using a coplanar delivery approach, VMAT might be further improved by including dynamic table and collimator rotations leading to dynamic trajectory radiotherapy (DTRT). In this work, an optimization procedure for DTRT was developed and the potential benefit of DTRT was investigated for different treatment sites. METHODS For this purpose, a dedicated optimization framework for DTRT was developed using the Eclipse Scripting Research Application Programming Interface (ESRAPI). The contours of the target and organs at risk (OARs) structures were exported by applying the ESRAPI and were used to determine the fractional volume-overlap of the OARs with the target from several potential beam directions. Thereby, an additional weighting was applied taking into account the relative position of the OAR with respect to the target and radiation beam, that is, penalizing directions where the OAR is proximal to the target. The resulting two-dimensional gantry-table map was used as input for an A* path finding algorithm returning an optimized gantry-table path. Thereby, the process is also taking into account CT scan length and collision restrictions. The A* algorithm was used again to determine the dynamic collimator angle path by optimizing the area between the MLC leaves and the target contour for each gantry-table path leading to gantry-collimator paths. The resulting gantry-table and gantry-collimator paths are combined and serve as input for the intensity modulation optimization using a research VMAT optimizer and the ESRAPI resulting in dynamic trajectories. This procedure was evaluated for five clinically motivated cases: two head and neck, one lung, one esophagus, and one prostate. Final dose calculations were performed using the Swiss Monte Carlo Plan (SMCP). Resulting dose distributions for the DTRT treatment plans and for the standard VMAT plans were compared based on dose distributions and dose volume histogram (DVH) parameters. For this comparison, the dose distribution for the VMAT plans were recalculated using the SMCP. In addition, the suitability of the delivery of a DTRT treatment plan was demonstrated by means of gafchromic film measurements on a TrueBeam linear accelerator. RESULTS DVHs for the target volumes showed similar or improved coverage and dose homogeneity for DTRT compared with VMAT using equal or less number of dynamic trajectories for DTRT than arcs for VMAT for all cases studied. Depending on the case, improvements in mean and maximum dose for the DTRT plans were achieved for almost all OARs compared with the VMAT plans. Improvements in DTRT treatment plans for mean and maximum dose compared to VMAT plans were up to 16% and 38% relative to the prescribed dose, respectively. The measured and calculated dose values resulted in a passing rate of more than 99.5% for the two-dimensional gamma analysis using 2% and 2 mm criteria and a threshold of 10%. CONCLUSIONS DTRT plans for different treatment sites were generated and compared with VMAT plans. The delivery is suitable and dose comparisons demonstrate a high potential of DTRT to reduce dose to OARs using less dynamic trajectories than arcs, while target coverage is preserved.

[1]  R Lee MacDonald,et al.  Dynamic trajectory-based couch motion for improvement of radiation therapy trajectories in cranial SRT. , 2014, Medical physics.

[2]  Michael K Fix,et al.  Dose calculation of dynamic trajectory radiotherapy using Monte Carlo. , 2019, Zeitschrift fur medizinische Physik.

[3]  Karl Otto,et al.  Volumetric modulated arc therapy: IMRT in a single gantry arc. , 2007, Medical physics.

[4]  Suresh Senan,et al.  Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study. , 2009, International journal of radiation oncology, biology, physics.

[5]  Michael K Fix,et al.  An efficient framework for photon Monte Carlo treatment planning , 2007, Physics in medicine and biology.

[6]  David A Jaffray,et al.  Intensity-modulated arc therapy with dynamic multileaf collimation : an alternative to tomotherapy , 2002 .

[7]  Ke Sheng,et al.  4π non-coplanar liver SBRT: a novel delivery technique. , 2013, International journal of radiation oncology, biology, physics.

[8]  Jeffrey C Bamber,et al.  Trajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy , 2013, Physics in medicine and biology.

[9]  R. L. Macdonald,et al.  Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning , 2018, Medical physics.

[10]  Uwe Oelfke,et al.  Noncoplanar VMAT for nasopharyngeal tumors: Plan quality versus treatment time. , 2015, Medical physics.

[11]  Ke Sheng,et al.  4π noncoplanar stereotactic body radiation therapy for centrally located or larger lung tumors. , 2013, International journal of radiation oncology, biology, physics.

[12]  Di Yan,et al.  Continuous arc rotation of the couch therapy for the delivery of accelerated partial breast irradiation: a treatment planning analysis. , 2011, International journal of radiation oncology, biology, physics.

[13]  M Pla,et al.  Dynamic stereotactic radiosurgery. , 1988, International journal of radiation oncology, biology, physics.

[14]  I. Kawrakow,et al.  VMC/sup ++/, a MC algorithm optimized for electron and photon beam dose calculations for RTP , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[15]  Christopher Barry Locke,et al.  Trajectory optimization in radiotherapy using sectioning (TORUS) , 2017, Medical physics.

[16]  Margie Hunt,et al.  Choreographing couch and collimator in volumetric modulated arc therapy. , 2011, International journal of radiation oncology, biology, physics.

[17]  Dimitre Hristov,et al.  Trajectory Modulated Arc Therapy: A Fully Dynamic Delivery With Synchronized Couch and Gantry Motion Significantly Improves Dosimetric Indices Correlated With Poor Cosmesis in Accelerated Partial Breast Irradiation. , 2014, International journal of radiation oncology, biology, physics.

[18]  Thomas Bortfeld,et al.  A modular approach to intensity-modulated arc therapy optimization with noncoplanar trajectories , 2015, Physics in medicine and biology.

[19]  G. Mageras,et al.  Optimization of collimator trajectory in volumetric modulated arc therapy: development and evaluation for paraspinal SBRT. , 2010, International journal of radiation oncology, biology, physics.

[20]  Nils J. Nilsson,et al.  A Formal Basis for the Heuristic Determination of Minimum Cost Paths , 1968, IEEE Trans. Syst. Sci. Cybern..

[21]  K Bush,et al.  Monte Carlo simulation of RapidArc radiotherapy delivery , 2008, Physics in medicine and biology.

[22]  Ke Sheng,et al.  4π noncoplanar stereotactic body radiation therapy for head-and-neck cancer: potential to improve tumor control and late toxicity. , 2014, International journal of radiation oncology, biology, physics.

[23]  M. Fix,et al.  Validation of the Swiss Monte Carlo Plan for a static and dynamic 6 MV photon beam. , 2011, Zeitschrift fur medizinische Physik.

[24]  Maria T. Vlachaki,et al.  Simultaneous couch and gantry dynamic arc rotation (CG‐Darc) in the treatment of breast cancer with accelerated partial breast irradiation (APBI): a feasibility study , 2013, Journal of applied clinical medical physics.

[25]  Ke Sheng,et al.  Feasibility of extreme dose escalation for glioblastoma multiforme using 4π radiotherapy , 2014, Radiation oncology.

[26]  Lei Xing,et al.  Trajectory modulated prone breast irradiation: a LINAC-based technique combining intensity modulated delivery and motion of the couch. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[27]  S. Spirou,et al.  Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators. , 1994, Medical physics.

[28]  J. Krayenbuehl,et al.  Dynamic intensity-modulated non-coplanar arc radiotherapy (INCA) for head and neck cancer. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[29]  P. Evans,et al.  Non-coplanar trajectories to improve organ at risk sparing in volumetric modulated arc therapy for primary brain tumors. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.