Coronary flow obstruction in percutaneous aortic valve replacement. An in vitro study.

OBJECTIVE Coronary flow obstruction is a serious complication reported in percutaneous aortic valve replacement. In an in vitro study of porcine hearts, the effects of valved stent implantation on coronary artery flow were studied with the native valve's leaflets intact and excised. METHODS The right and left main coronary arteries of porcine hearts were dissected 20mm distal to the aortic root and directed into lengths of latex tubing leading to collection flasks. The ascending aorta was cut proximal to the brachiocephalic trunk, cannulated, and attached to a constant-head water supply. After steady flow was achieved, the flow rate from each coronary artery was measured. In Group A (n=10), a tubular pericardial valve sutured into a cylindrical, cobalt-nickel stent was deployed orthotopically using a valvuloplasty balloon catheter. In Group B (n=10), the native leaflets were removed before similar valve deployment. Coronary flow measurements were repeated post-implantation. RESULTS In Group A, valve implantation resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after valve placement. CONCLUSION Implantation of a percutaneous valved stent in the orthotopic position with the native valve in place causes coronary ostial obstruction. This problem highlights the need for modified stents that are designed for implantation in patients with non-retracted, fibrotic, or calcified leaflets.

[1]  A. Boening,et al.  Percutaneous aortic valve replacement: resection before implantation. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[2]  M. Cheitlin Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery , 2007 .

[3]  E. Lansac,et al.  A four-dimensional study of the aortic root dynamics. , 2002, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[4]  Younes Boudjemline,et al.  Steps Toward Percutaneous Aortic Valve Replacement , 2002, Circulation.

[5]  F. Beyersdorf,et al.  Percutaneous aortic valve replacement: an experimental study. I. Studies on implantation , 2002 .

[6]  K. J. Grande,et al.  Porcine Aortic Leaflet Arrangement May Contribute to Clinical Xenograft Failure , 1993, ASAIO journal.

[7]  Hou-Sen Lim,et al.  A temporarily stented, autologous pericardial aortic valve prosthesis. , 2002, The Journal of heart valve disease.

[8]  Anson Cheung,et al.  Transapical Transcatheter Aortic Valve Implantation in Humans: Initial Clinical Experience , 2006, Circulation.

[9]  N. Borenstein,et al.  A repositionable valved stent for endovascular treatment of deteriorated bioprostheses. , 2006, Journal of the American College of Cardiology.

[10]  L. Cohn,et al.  Direct-access valve replacement a novel approach for off-pump valve implantation using valved stents. , 2005, Journal of the American College of Cardiology.

[11]  J M Hasenkam,et al.  Transluminal implantation of artificial heart valves. Description of a new expandable aortic valve and initial results with implantation by catheter technique in closed chest pigs. , 1992, European heart journal.

[12]  C. Duran,et al.  Aortic root geometry: pattern of differences between leaflets and sinuses of Valsalva. , 1999, The Journal of heart valve disease.