Operation of the Preclinical Head Scanner for Proton CT.

We report on the operation and performance tests of a preclinical head scanner developed for proton computed tomography (pCT). After extensive preclinical testing, pCT is intended to be employed in support of proton therapy treatment planning and pre-treatment verification in patients undergoing particle-beam therapy. In order to assess the performance of the scanner, we have performed CT scans with 200 MeV protons from both the synchrotron of the Loma Linda University Medical Center (LLUMC) and the cyclotron of the Northwestern Medicine Chicago Proton Center (NMCPC). The very high sustained rate of data acquisition, exceeding one million protons per second, allowed a full 360° scan to be completed in less than 7 minutes. The reconstruction of various phantoms verified accurate reconstruction of the proton relative stopping power (RSP) and the spatial resolution in a variety of materials. The dose for an image with better than 1% uncertainty in the RSP is found to be close to 1 mGy.

[1]  A B Rosenfeld,et al.  A more accurate reconstruction system matrix for quantitative proton computed tomography. , 2009, Medical physics.

[2]  H. Sadrozinski,et al.  Design and properties of the GLAST flight silicon micro-strip sensors , 2005 .

[3]  V Giacometti,et al.  Novel scintillation detector design and performance for proton radiography and computed tomography. , 2016, Medical physics.

[4]  Blake Schultze,et al.  A Fast Experimental Scanner for Proton CT: Technical Performance and First Experience With Phantom Scans , 2016, IEEE Transactions on Nuclear Science.

[5]  A B Rosenfeld,et al.  Total variation superiorization schemes in proton computed tomography image reconstruction. , 2010, Medical physics.

[6]  A. Seiden,et al.  Toward proton computed tomography , 2002, IEEE Transactions on Nuclear Science.

[7]  A Ghebremedhin,et al.  Water-equivalent path length calibration of a prototype proton CT scanner. , 2012, Medical physics.

[8]  D. Williams,et al.  The most likely path of an energetic charged particle through a uniform medium. , 2004, Physics in medicine and biology.

[9]  Reinhard W Schulte,et al.  Development of proton computed tomography detectors for applications in hadron therapy. , 2016, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[10]  H. Sadrozinski,et al.  Development of a Head Scanner for Proton CT. , 2013, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment.

[11]  S N Penfold,et al.  A maximum likelihood proton path formalism for application in proton computed tomography. , 2008, Medical physics.

[12]  A. Dell'Acqua,et al.  Geant4 - A simulation toolkit , 2003 .

[13]  Joel DeWitt,et al.  Tracker Readout ASIC for Proton Computed Tomography Data Acquisition , 2013, IEEE Transactions on Nuclear Science.

[14]  E Honda,et al.  Modulation transfer function evaluation of cone beam computed tomography for dental use with the oversampling method. , 2010, Dento maxillo facial radiology.

[15]  H. Sadrozinski,et al.  Design of a proton computed tomography system for applications in proton radiation therapy , 2004, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).