Fluorescence optical fibre sensor provides accurate continuous oxygen detection in rabbit model with acute lung injury
暂无分享,去创建一个
C. Bai | Shujing Chen | Jinjun Jiang | Yuanlin Song | W. Zhong | Yuehong WANG | Sheng MENG | Yuanlin SONG | Wei ZHONG | Jinjun JIANG | Shujing CHEN | Chunxue BAI | Sheng Meng | Yuehong Wang
[1] D. Altman,et al. STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.
[2] N. Opitz,et al. Optical Fluorescence and Its Application to an Intravascular Blood Gas Monitoring System , 1986, IEEE Transactions on Biomedical Engineering.
[3] Sifu Zhang,et al. Investigation of an optical fibre pH sensor with the membrane based on phospholipid copolymer , 1996 .
[4] K. Tremper,et al. Pulse oximetry. , 1989, Anesthesiology.
[5] G. Heninger,et al. PHENOXYBENZAMINE IN ANOREXIA NERVOSA , 1976, The Lancet.
[6] K. Tremper,et al. Continuous intravascular blood gas monitoring. , 1994, Journal of cardiothoracic and vascular anesthesia.
[7] P. Ward,et al. Oleic-acid-induced lung injury in the rat. Failure of indomethacin treatment or complement depletion to ablate lung injury. , 1981, The American journal of pathology.
[8] C. K. Mahutte. Continuous intra-arterial blood gas monitoring , 2005, Intensive Care Medicine.
[9] F. Lemaire,et al. Accuracy of pulse oximetry in the intensive care unit , 2001, Intensive Care Medicine.
[10] E. Lucchinetti,et al. Substantial Changes in Arterial Blood Gases During Thoracoscopic Surgery Can Be Missed by Conventional Intermittent Laboratory Blood Gas Analyses , 1998, Anesthesia and analgesia.
[11] C. Bai,et al. Development of fiber optic fluorescence oxygen sensor in both in vitro and in vivo systems , 2008, Respiratory Physiology & Neurobiology.
[12] T. H. Clutton-Brock,et al. The evaluation of a new intravascular blood gas monitoring system in the pig , 1994, Journal of Clinical Monitoring.
[13] W. W. Miller,et al. Performance of an in-vivo, continuous blood-gas monitor with disposable probe. , 1987, Clinical chemistry.
[14] B. Venkatesh,et al. Misleading information from pulse oximetry and the usefulness of continuous blood gas monitoring in a post cardiac surgery patient , 1995, Intensive Care Medicine.
[15] R. C. Dennis,et al. Effect of sample dilutions on arterial blood gas determinations. , 1985, Critical care medicine.
[16] A Zollinger,et al. Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device. , 2003, British journal of anaesthesia.
[17] B. Smoller,et al. Phlebotomy for diagnostic laboratory tests in adults. Pattern of use and effect on transfusion requirements. , 1986, The New England journal of medicine.
[18] C. K. Mahutte,et al. On-line arterial blood gas analysis with optodes: current status. , 1998, Clinical biochemistry.
[19] Douglas G. Altman,et al. Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .
[20] J. Zimmerman,et al. Continuous Intra-Arterial Blood Gas Monitoring , 1995 .
[21] S J Barker,et al. Continuous Measurement of Intraarterial pHa, Paco2, and Pao2, in the Operating Room , 1991, Anesthesia and analgesia.
[22] S. Rithalia,et al. Developments in transcutaneous blood gas monitoring: a review. , 1991, Journal of medical engineering & technology.