A Stress Sensor Based on Galvanic Skin Response (GSR) Controlled by ZigBee

Sometimes, one needs to control different emotional situations which can lead the person suffering them to dangerous situations, in both the medium and short term. There are studies which indicate that stress increases the risk of cardiac problems. In this study we have designed and built a stress sensor based on Galvanic Skin Response (GSR), and controlled by ZigBee. In order to check the device's performance, we have used 16 adults (eight women and eight men) who completed different tests requiring a certain degree of effort, such as mathematical operations or breathing deeply. On completion, we appreciated that GSR is able to detect the different states of each user with a success rate of 76.56%. In the future, we plan to create an algorithm which is able to differentiate between each state.

[1]  H. L. Andrews SKIN RESISTANCE CHANGES AND MEASUREMENTS OF PAIN THRESHOLD. , 1943, The Journal of clinical investigation.

[2]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[3]  Kenneth R. Foster,et al.  Electrical Injuries. Engineering, Medical, and Legal Aspects. , 2000 .

[4]  M. Tarvainen,et al.  Principal component analysis of galvanic skin responses , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[5]  Li Jiang,et al.  A novel approach to analyze the result of polygraph , 2000, Smc 2000 conference proceedings. 2000 ieee international conference on systems, man and cybernetics. 'cybernetics evolving to systems, humans, organizations, and their complex interactions' (cat. no.0.

[6]  Jiang Li,et al.  A novel approach to analyze the result of polygraph , 2000, SMC.

[7]  P.A. Karjalainen,et al.  of the 23 rd Annual EMBS International Conference , October 25-28 , Istanbul , Turkey Software Package for Bio-Signal Analysis , 2004 .

[8]  C. Cooper,et al.  Stress: A Brief History , 2004 .

[9]  Chao Li,et al.  Realization of stress detection using psychophysiological signals for improvement of human-computer interactions , 2005, Proceedings. IEEE SoutheastCon, 2005..

[10]  Li Cui,et al.  EasiMed: A remote health care solution , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[11]  A. Barreto,et al.  Stress Detection in Computer Users Based on Digital Signal Processing of Noninvasive Physiological Variables , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  S. Tanaka,et al.  Feasibility study on driver's stress detection from differential skin temperature measurement , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[13]  J.Y. Jung,et al.  ZigBee Device Access Control and Reliable Data Transmission in ZigBee Based Health Monitoring System , 2008, 2008 10th International Conference on Advanced Communication Technology.

[14]  Shahin Farahani,et al.  ZigBee Wireless Networks and Transceivers , 2008 .

[15]  S. A. Hosseini,et al.  Emotional Stress Recognition System Using EEG and Psychophysiological Signals: Using New Labelling Process of EEG Signals in Emotional Stress State , 2010, 2010 International Conference on Biomedical Engineering and Computer Science.

[16]  Wanhui Wen,et al.  Construction and cross-correlation analysis of the affective physiological response database , 2010, Science China Information Sciences.

[17]  Guanghua Wu,et al.  The Analysis of Emotion Recognition from GSR Based on PSO , 2010, 2010 International Symposium on Intelligence Information Processing and Trusted Computing.

[18]  Chuan-Yu Chang,et al.  Based on Support Vector Regression for emotion recognition using physiological signals , 2010, The 2010 International Joint Conference on Neural Networks (IJCNN).

[19]  Martin L. Griss,et al.  Activity-Aware Mental Stress Detection Using Physiological Sensors , 2010, MobiCASE.

[20]  Adrian Burns,et al.  SHIMMER™ – A Wireless Sensor Platform for Noninvasive Biomedical Research , 2010, IEEE Sensors Journal.

[21]  Shusaku Nomura,et al.  Evaluation of Student's Physiological Response Towards E-Learning Courses Material by Using GSR Sensor , 2010, 2010 IEEE/ACIS 9th International Conference on Computer and Information Science.

[22]  Kai Keng Ang,et al.  A Brain-Computer Interface for classifying EEG correlates of chronic mental stress , 2011, The 2011 International Joint Conference on Neural Networks.

[23]  Gonzalo Bailador,et al.  A Stress-Detection System Based on Physiological Signals and Fuzzy Logic , 2011, IEEE Transactions on Industrial Electronics.

[24]  Franz Gravenhorst,et al.  Towards long term monitoring of electrodermal activity in daily life , 2013, Personal and Ubiquitous Computing.

[25]  Shaomei Wu,et al.  Exploring the use of physiology in adaptive game design , 2011, 2011 International Conference on Consumer Electronics, Communications and Networks (CECNet).

[26]  R. Gutierrez-Osuna,et al.  Removal of Respiratory Influences From Heart Rate Variability in Stress Monitoring , 2011, IEEE Sensors Journal.

[27]  Tao Huang,et al.  Design and Implementation of a Wireless Healthcare System Based on Galvanic Skin Response , 2011, ICAIC.

[28]  C. Gehin,et al.  EmoSense: An Ambulatory Device for the Assessment of ANS Activity—Application in the Objective Evaluation of Stress With the Blind , 2012, IEEE Sensors Journal.

[29]  M. Benedi Resistencia de la piel al paso de la corriente eléctrica en adultos trabajadores , 2012 .

[30]  P. Brunswick,et al.  Noninvasive Galvanic Skin Sensor for Early Diagnosis of Sudomotor Dysfunction: Application to Diabetes , 2012, IEEE Sensors Journal.