Comparison of subtraction arthrography, radionuclide arthrography and conventional plain radiography to assess loosening of total knee arthroplasty / Vergleich von Subtraktionsarthrographie, Radionuklidarthrographie und konventionellem Röntgen zur Erfassung von Prothesenlockerungen in der Knierevisi

Abstract The value of plain radiographs, digital subtraction arthrography and radionuclide arthrography was analysed in 23 cases of failed total knee arthroplasty. The preoperative diagnosis was compared with the intraoperative assessment. Sensitivity, specificity and the positive and negative predictive value for assessing a loose component were determined separately for the femoral and tibial components. At revision we found 13 loose femoral and 12 loose tibial implants. In eight cases both components were unstable. Plain radiography had a sensitivity of 77% for loosening of the femoral and 83% for the tibial component; digital subtraction arthrography 77% for the femoral and 8% for the tibial component and radionuclide arthrography 31% and 8%. The specificity for plain radiography was 90% for the femoral and 72% for the tibial implant. For subtraction arthrography it was 50% and 82% and for subtraction arthrography 70% and 82%. Radiography had the highest positive and negative predictive values for both components compared with the other two techniques. As a diagnostic tool to detect implant loosening, plain radiography is the most effective in this study. Subtraction arthrography and radionuclide arthrography are not suitable for use as routine methods for detection of total knee arthroplasty loosening. In 23 Revisionen einer Kniegelenkstotalendoprothese wurden konventionelle Röntgenbilder, digitale Subtraktionsarthrographien und Radionuklidarthrographien analysiert, um die Effizienz dieser Methoden hinsichtlich der Diagnose von Implantatlockerungen festzustellen. Die präoperative Diagnose wurde mit dem intraoperativen Befund verglichen. Sensitivität, Spezifität und der positive und negative Vorhersagewert zu Erfassung einer Prothesenlockerung wurden separat für die femorale und tibiale Komponente erfasst. Bei der Revision wurden 13 gelockerte femorale und 12 gelockerte tibiale Implantate gefunden. In acht Fällen waren beide Komponenten gelockert. Konventionelles Röntgen hatte eine Sensitivität von 77% zur Erfassung einer Lockerung des femoralen Schilds bzw. 83% für die tibiale Komponente; die digitale Subtraktionsarthrographie ergab 77% für das femorale und 8% für das tibiale Implantat; die Radionuklidarthrographie hatte eine Sensitivität von 31% und 8%. Die Spezifität für konventionelles Röntgen lag bei 90% für femoral und 72% für tibial. Für die digitale Subtraktionsarthrographie waren es 50% und 82% und für die Radionuklidarthrographie 70% und 82%. Konventionelles Röntgen hatte den höchsten positiven und negativen Vorhersagewert für beide Komponenten verglichen mit den beiden anderen Techniken. Als diagnostisches Verfahren zur Erfassung einer Prothesenlockerung stellte sich das konventionelle Röntgen in dieser Studie als die effektivste Methode heraus. Die digitale Subtraktionsarthrographie bzw. die Radionuklidarthrographie eignen sich nicht als Routineverfahren zur Erfassung einer Kniegelenkstotalendoprothesenlockerung.

[1]  F. Löer,et al.  The Diagnostic Value of Digital Subtraction Arthrography and Radionuclide Arthrography in Revision Total Hip Arthroplasty / Der diagnostische Wert der digitalen Subtraktionsarthrographie und der Radionuklidarthrographie in der Revisionschirurgie des Hüftgelenkersatzes , 2004, Biomedizinische Technik. Biomedical engineering.

[2]  J. Berkhof,et al.  A comparison of radiographic and scintigraphic techniques to assess aseptic loosening of the acetabular component in a total hip replacement. , 2004, Journal of Bone and Joint Surgery. American volume.

[3]  Douglas A Dennis,et al.  Evaluation of painful total knee arthroplasty. , 2004, The Journal of arthroplasty.

[4]  G. Köster,et al.  Clinical value of combined contrast and radionuclide arthrography in suspected loosening of hip prostheses , 2004, Archives of Orthopaedic and Trauma Surgery.

[5]  Mohamed R. Mahfouz,et al.  In Vivo Fluoroscopic Analysis Of Fixed-Bearing Total Knee Replacements , 2003, Clinical orthopaedics and related research.

[6]  D. Wirtz,et al.  Erste Erfahrungen mit der Fluorodeoxyglukose-Positronenemissionstomographie (FDG-PET) in der Diagnostik schmerzhafter Knie- und Hüfttotalendoprothesen , 2003 .

[7]  R. Laskin,et al.  Magnetic Resonance Imaging of Total Knee Arthroplasty , 2003, Clinical orthopaedics and related research.

[8]  U. Cremerius,et al.  [First experiences with fluorodeoxyglucose-positron-emission tomography (FDG-PET) in the evaluation of painful total knee and hip joint replacements]. , 2003, Zeitschrift fur Orthopadie und ihre Grenzgebiete.

[9]  R. T. Müller,et al.  Stellenwert der digitalen Subtraktionsarthrografie und Arthroszintigrafie in der Indikationsstellung und Planung der Hüft-TEP-Wechseloperation , 2001 .

[10]  A. Alavi,et al.  The promising role of 18F-FDG PET in detecting infected lower limb prosthesis implants. , 2001, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  V. Goymann,et al.  [Value of digital subtraction arthrography and radionuclide arthrography in determination of indications and planning of revision surgery in total hip replacement]. , 2001, RöFo. Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren (Print).

[12]  B. Barden,et al.  Failure Mechanisms in Total Hip and Knee Arthroplasty: A Morphologic and Radiologic Study , 1999 .

[13]  P. Lachiewicz,et al.  The role of aspiration and contrast-enhanced arthrography in evaluating the uncemented hip arthroplasty. , 1997, AJR. American journal of roentgenology.

[14]  T. Fehring,et al.  Fluoroscopic Evaluation of the Painful Total Knee Arthroplasty , 1996, Clinical orthopaedics and related research.

[15]  W. Hop,et al.  Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty , 1996, Skeletal Radiology.

[16]  D. Howie,et al.  Plain film and arthrographic findings in painful total hip arthroplasties with surgical correlation. , 1990, Australasian radiology.

[17]  R. Bourne,et al.  Analysis of radionuclide arthrograms, radiographic arthrograms, and sequential plain radiographs in the assessment of painful hip arthroplasty. , 1990, The Journal of arthroplasty.

[18]  F. C. Ewald The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. , 1989, Clinical orthopaedics and related research.

[19]  J. Tehranzadeh,et al.  Prospective Study of Sequential Technetium‐99 Phosphate and Gallium Imaging in Painful Hip Prostheses (Comparison of Diagnostic Modalities) , 1988, Clinical nuclear medicine.

[20]  R. Hendrix,et al.  Arthrographic and radiologic evaluation of prosthetic joints. , 1981, Radiologic clinics of North America.

[21]  H. Amstutz,et al.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. , 1979, Clinical orthopaedics and related research.

[22]  J. Charnley,et al.  Radiological demarcation of cemented sockets in total hip replacement. , 1976, Clinical orthopaedics and related research.