Developing a methodology for analysis and manufacturing of proximal interphalangeal (PIP) joint using rapid prototyping technique

Purpose – The purpose of this paper is to design and analyze four proximal interphalangeal joint (PIP) prosthesis thorough finite element analysis (FEA) and fabricate them using rapid prototyping (RP) technique. Arthritis of the finger joints is an important pathology of the hand. Major complaints in arthritis are stiffness, deformity and severe pain. The pain is due to the inflammatory process that occurs due to pathology, which involves joint degeneration, synovial swelling and ligament and muscle stiffness. Among the surgical treatment of arthritis is Arthroplasty which involves replacing the diseased joint with an artificial joint. Design/methodology/approach – In this paper, four proximal interphalangeal joint (PIP) prostheses are designed, analyzed using FEA and fabricated using rapid prototyping technique. Four different prostheses “BM”, “IMP”, “IMP2” and “FINS” are designed using CATIA software and tested by normal daily functions such as grasp, key pinch and tip pinch tests using FEA to analyze t...

[1]  T. R. Deshmukh,et al.  A novel rapid prototyping and finite element method-based development of the patient-specific temporomandibular joint implant , 2012, Computer methods in biomechanics and biomedical engineering.

[2]  D. Bruce Imaging after head trauma: why, when and which , 2000, Child's Nervous System.

[3]  Steven M. Kurtz,et al.  The UHMWPE Handbook: Ultra-High Molecular Weight Polyethylene in Total Joint Replacement , 2004 .

[4]  V. Bagaria,et al.  Use of rapid prototyping and three-dimensional reconstruction modeling in management of complex acetabular fracture , 2009 .

[5]  Jayanthi Parthasarathy Design, analysis and fabrication of porous titanium implants using electron beam melting for craniofacial applications , 2009 .

[6]  Margareta Nordin,et al.  Basic Biomechanics of the Musculoskeletal Systm , 1989 .

[7]  F. Migliavacca,et al.  Use of rapid prototyping models in the planning of percutaneous pulmonary valved stent implantation , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  Rickard Brånemark,et al.  Biomechanical, histological, and ultrastructural analyses of laser micro- and nano-structured titanium alloy implants: a study in rabbit. , 2009, Journal of biomedical materials research. Part A.

[9]  K. Nuss Has surgical treatment of septic arthritis of the distal interphalangeal joint in cattle moved forward? , 2009, Veterinary journal.

[10]  Ryan B. Wicker,et al.  Next Generation Orthopaedic Implants by Additive Manufacturing Using Electron Beam Melting , 2012, International journal of biomaterials.

[11]  Vaibhav Bagaria,et al.  Application of the rapid prototyping technique to design a customized temporomandibular joint used to treat temporomandibular ankylosis , 2009, Indian journal of plastic surgery : official publication of the Association of Plastic Surgeons of India.

[12]  M. Østergaard,et al.  Magnetic resonance imaging, radiography, and scintigraphy of the finger joints: one year follow up of patients with early arthritis , 2000, Annals of the rheumatic diseases.

[13]  J. Nunley,et al.  Posttraumatic Proximal Interphalangeal Joint Flexion Contractures , 2006, The Journal of the American Academy of Orthopaedic Surgeons.

[14]  K. Schmidt,et al.  Endoprothetik des Fingergrundgelenks , 2007, Zeitschrift für Rheumatologie.

[15]  Ian Gibson,et al.  Fatigue and wear evaluation of a novel artificial finger joint , 2002 .

[16]  J. Giannatsis,et al.  Additive fabrication technologies applied to medicine and health care: a review , 2009 .

[17]  Magnetic resonance imaging of the wrist in early rheumatoid arthritis: a pictorial essay. , 2001, Australasian radiology.

[18]  J Goldhahn,et al.  Problematic Bone Fixation with Pyrocarbon Implants in Proximal Interphalangeal Joint Replacement: Short-Term Results , 2006, Journal of hand surgery.

[19]  Anders Snis,et al.  Electron beam-melted, free-form-fabricated titanium alloy implants: Material surface characterization and early bone response in rabbits. , 2008, Journal of biomedical materials research. Part B, Applied biomaterials.

[20]  Karl Knahr,et al.  Total Hip Arthroplasty , 2012 .

[21]  W. Cooney,et al.  Long-term assessment of Swanson implant arthroplasty in the proximal interphalangeal joint of the hand. , 2004, The Journal of hand surgery.

[22]  A. Swanson,et al.  Flexible implant arthroplasty for arthritic finger joints: rationale, technique, and results of treatment. , 1972, The Journal of bone and joint surgery. American volume.

[23]  J. Peck Weight-bearing surfaces. , 2013 .