In vitro speed of sound measurement at intact human femur specimens.

Quantitative ultrasound has been recognized as a useful tool for fracture risk prediction. Current measurement techniques are limited to peripheral skeletal sites. Our objective was to demonstrate the in vitro feasibility of ultrasonic velocity measurements on human proximal femur and to investigate the relationship between velocity and bone mineral density (BMD). Sound velocity images were computed from 2-D scans performed on 38 excised human femurs in transmission at 0.5 MHz. Different regions-of-interest were investigated. Dual x-ray absorptiometry scans have been achieved for BMD measurements in site-matched regions. Our study demonstrates the feasibility of ultrasonic velocity measurements at the hip with reasonable precision (coefficient of variation of 0.3%). The best prediction of BMD was reached in the intertrochanter region (r(2) = 0.91, p < 10(-4)), with a residual error of 0.06 g/cm(2) (10%). Because BMD measured at the femur is the best predictor of hip fracture risk, the highly significant correlation and small residual error found in this study suggest that speed of sound measurement at the femur might be a good candidate for hip fracture risk prediction.

[1]  G Lowet,et al.  Assessment of the strength of the proximal femur in vitro: relationship with ultrasonic measurements of the calcaneus. , 1997, Bone.

[2]  R. B. Ashman,et al.  Elastic modulus of trabecular bone material. , 1988, Journal of Biomechanics.

[3]  Pascal Laugier,et al.  Prediction of frequency-dependent ultrasonic backscatter in cancellous bone using statistical weak scattering model. , 2003, Ultrasound in medicine & biology.

[4]  J. Cunningham,et al.  Ultrasound velocity and attenuation at different skeletal sites compared with bone mineral density measured using dual energy X-ray absorptiometry. , 1996, The British journal of radiology.

[5]  Harry K. Genant,et al.  Quantitative Ultrasound: Assessment of Osteoporosis and Bone Status , 1999 .

[6]  M. Ooms,et al.  Ultrasound measurements in the calcaneus: precision and its relation with bone mineral density of the heel, hip, and lumbar spine. , 1996, Bone.

[7]  F. Patat,et al.  Bidirectional axial transmission can improve accuracy and precision of ultrasonic velocity measurement in cortical bone: a validation on test materials , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  W. C. Hayes,et al.  Stress distributions within the proximal femur during gait and falls: Implications for osteoporotic fracture , 2005, Osteoporosis International.

[9]  A. Tenenhouse,et al.  Correlation of ultrasound velocity in the tibial cortex, calcaneal ultrasonography, and bone mineral densitometry of the spine and femur , 1996, Calcified Tissue International.

[10]  B. Stampa,et al.  Assessment of the Geometry of Human Finger Phalanges Using Quantitative Ultrasound In Vivo , 2000, Osteoporosis International.

[11]  M. Bouxsein,et al.  Prediction of the strength of the elderly proximal femur by bone mineral density and quantitative ultrasound measurements of the heel and tibia. , 1999, Bone.

[12]  O. Johnell,et al.  Meta-analysis of how well measures of bone mineral density predict occurrence of osteoporotic fractures , 1996 .

[13]  D. Hosking,et al.  The relationship between bone mineral density and ultrasound in postmenopausal and osteoporotic women , 2007, Osteoporosis International.

[14]  C. Langton,et al.  The measurement of broadband ultrasonic attenuation in cancellous bone. , 1984, Engineering in medicine.

[15]  S. Majumdar,et al.  High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties. , 1998, Bone.

[16]  K. Wear,et al.  Relationships of ultrasonic backscatter with ultrasonic attenuation, sound speed and bone mineral density in human calcaneus. , 2000, Ultrasound in medicine & biology.

[17]  G M Owen,et al.  Factors affecting the in vivo precision of broad-band ultrasonic attenuation. , 1995, Physics in medicine and biology.

[18]  Martin Heller,et al.  Assessing Bone Status Beyond BMD: Evaluation of Bone Geometry and Porosity by Quantitative Ultrasound of Human Finger Phalanges , 2004, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[19]  R. Putz,et al.  Correlation of Femoral and Lumbar DXA and Calcaneal Ultrasound, Measured In Situ with Intact Soft Tissues, with the In Vitro Failure Loads of the Proximal Femur , 1998, Osteoporosis International.

[20]  C C Glüer,et al.  Osteoporosis: association of recent fractures with quantitative US findings. , 1996, Radiology.

[21]  P. Rüegsegger,et al.  In vivo high resolution 3D-QCT of the human forearm. , 1998, Technology and health care : official journal of the European Society for Engineering and Medicine.

[22]  F. Padilla,et al.  In Vitro Ultrasound Measurement at the Human Femur , 2004, Calcified Tissue International.

[23]  V Bousson,et al.  In vitro ultrasonic characterization of human cancellous femoral bone using transmission and backscatter measurements: relationships to bone mineral density. , 2006, The Journal of the Acoustical Society of America.

[24]  G. Berger,et al.  Ultrasound parametric imaging of the calcaneus:In vivo results with a new device , 1996, Calcified Tissue International.

[25]  R. Norris Medical costs of osteoporosis. , 1992, Bone.

[26]  P. Laugier,et al.  Velocity dispersion of acoustic waves in cancellous bone , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  Françoise Peyrin,et al.  An In Vitro Study of the Ultrasonic Axial Transmission Technique at the Radius: 1‐MHz Velocity Measurements Are Sensitive to Both Mineralization and Intracortical Porosity , 2004, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[28]  P. Emery,et al.  Evaluation of Finger Ultrasound in the Assessment of Bone Status with Application of Rheumatoid Arthritis , 1999, Osteoporosis International.

[29]  R. Luypaert,et al.  Quantitative ultrasound of the calcaneus: an in vivo comparison with dual-energy X-ray absorptiometry and magnetic resonance imaging. , 2000, Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry.

[30]  Kang I L Lee,et al.  Correlations between acoustic properties and bone density in bovine cancellous bone from 0.5 to 2 MHz. , 2003, The Journal of the Acoustical Society of America.

[31]  O. Johnell,et al.  Comparison of Quantitative Ultrasound Measurements in Calcaneus with DXA and SXA at Other Skeletal Sites: A Population-Based Study on 280 Children Aged 11–16 Years , 1998, Osteoporosis International.

[32]  Reinhard Barkmann,et al.  Association of Five Quantitative Ultrasound Devices and Bone Densitometry With Osteoporotic Vertebral Fractures in a Population‐Based Sample: The OPUS Study , 2004, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[33]  P. Ross,et al.  Prediction of Fracture Risk by Radiographic Absorptiometry and Quantitative Ultrasound: A Prospective Study , 1998, Calcified Tissue International.

[34]  M. Laval-jeantet,et al.  Ultrasound attenuation imaging in the os calcis: an improved method. , 1994, Ultrasonic imaging.

[35]  J. Taylor,et al.  Quantitative Heel Ultrasound in 3180 Women Between 45 and 75 Years of Age: Compliance, Normal Ranges and Relationship to Fracture History , 1998, Osteoporosis International.

[36]  R. C. Murry,et al.  Measurement of mechanical properties of bone material in vitro by ultrasound reflection: Methodology and comparison with ultrasound transmission , 1991, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[37]  H. K. Genant,et al.  Comparison of Six Calcaneal Quantitative Ultrasound Devices: Precision and Hip Fracture Discrimination , 2000, Osteoporosis International.

[38]  G. Breart,et al.  Ultrasonographic heel measurements to predict hip fracture in elderly women: the EPIDOS prospective study , 1996, The Lancet.

[39]  C. Wu,et al.  Assessment of a New Quantitative Ultrasound Calcaneus Measurement: Precision and Discrimination of Hip Fractures in Elderly Women Compared with Dual X-ray Absorptiometry , 2000, Osteoporosis International.

[40]  P Rüegsegger,et al.  High-resolution three-dimensional-pQCT images can be an adequate basis for in-vivo μFE analysis of bone , 2001 .

[41]  H. Genant,et al.  Comparison of ultrasound and bone mineral density assessment of the calcaneus with different regions of interest in healthy early menopausal women. , 1999, Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry.

[42]  M. Jergas,et al.  Accurate assessment of precision errors: How to measure the reproducibility of bone densitometry techniques , 2005, Osteoporosis International.

[43]  K. Wear,et al.  Measurements of phase velocity and group velocity in human calcaneus. , 2000, Ultrasound in medicine & biology.

[44]  R Porcher,et al.  Ultrasonic Backscatter and Transmission Parameters at the Os Calcis in Postmenopausal Osteoporosis , 2001, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[45]  Jacques P. Brown,et al.  Standards and guidelines for performing central dual-energy x-ray absorptiometry in premenopausal women, men, and children. , 2004, Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry.

[46]  Regular ArticleUltrasound Attenuation Imaging in the Os Calcis: An Improved Method , 1994 .

[47]  H. Genant,et al.  Comparison of an imaging heel quantitative ultrasound device (DTU-one) with densitometric and ultrasonic measurements. , 2000, The British journal of radiology.

[48]  P Rüegsegger,et al.  Do quantitative ultrasound measurements reflect structure independently of density in human vertebral cancellous bone? , 1998, Bone.

[49]  C. Langton,et al.  Comparison of bone mineral density and quantitative ultrasound of the calcaneus: site-matched correlation and discrimination of axial BMD status. , 2000, The British journal of radiology.

[50]  G. Blake,et al.  Ultrasonic velocity measurements through the calcaneus: Which velocity should be measured? , 2005, Osteoporosis International.

[51]  X Ouyang,et al.  A Comparative Study of Trabecular Bone Properties in the Spine and Femur Using High Resolution MRI and CT , 1998, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[52]  Harry K. Genant,et al.  Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women. A prospective study. Study of Osteoporotic Fractures Research Group. , 1997, Archives of internal medicine.

[53]  F Peyrin,et al.  Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructure. , 2002, Bone.

[54]  C. M. Langton,et al.  Prediction of Human Femoral Bone Strength Using Ultrasound Velocity and BMD: An In Vitro Study , 1997, Osteoporosis International.

[55]  J. Kanis,et al.  Diagnosis of osteoporosis and assessment of fracture risk , 2002, The Lancet.

[56]  H K Genant,et al.  A new method for quantitative ultrasound measurements at multiple skeletal sites: first results of precision and fracture discrimination. , 2000, Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry.

[57]  S. Majumdar,et al.  High-resolution MRI vs multislice spiral CT: Which technique depicts the trabecular bone structure best? , 2003, European Radiology.

[58]  G Berger,et al.  In vitro assessment of the relationship between acoustic properties and bone mass density of the calcaneus by comparison of ultrasound parametric imaging and quantitative computed tomography. , 1997, Bone.

[59]  J. Cauley,et al.  Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women. A prospective study. Study of Osteoporotic Fractures Research Group. , 1997, Archives of Internal Medicine.

[60]  M. Laval-jeantet,et al.  Ultrasound attenuation imaging in the OS calcis , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[61]  M. Bouxsein,et al.  Quantitative Ultrasound of the Calcaneus Reflects the Mechanical Properties of Calcaneal Trabecular Bone , 1997, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.