Low temperature nanointegration for emerging biomedical applications

Abstract In this paper, surface activated nanointegration of computational, electrical, optical, and mechanical structures for intelligent telemetry, communication, and sensing systems is described. The design approach and integration of top-down systems and bottom-up devices is considered with the need for biologically compatible bonding. For the simplified interface between bottom-up and top-down design a bus-bar unit architecture is presented. Emerging biomedical applications using intelligent sensors for remote patient monitoring and systems for rehabilitation comparing surface vs. implanted sensors are considered. Requirements for nanointegration of biomedical systems are suggested. Diverse combinations of rigid and flexible substrates of copper, gold, gallium arsenide, gallium phosphide and liquid crystal polymer were bonded by using two different nanobonding techniques. In these techniques, the surface cleaning with/without simultaneous deposition of nano-adhesion layers and contact in ultra-high vacuum/high vacuum were accomplished. These nanobonding technologies provide void-free, strong, and nanometer scale covalent bonding at room temperature or at low temperatures (∼240 °C), and do not require chemicals, adhesives, or high external pressure. A considerable electrical current conduction and low loss of the nanobonded laminate was observed at high frequency. This investigation reveals that a biocompatible, high performance, and miniaturized systems may be realized for intelligent, implantable biomedical sensors because of the strong bond, low toxicity and favorable electrical properties in surface activated nanobonding.

[1]  Rémy Braive,et al.  Heterogeneous integration and precise alignment of InP-based photonic crystal lasers to complementary metal-oxide semiconductor fabricated silicon-on-insulator wire waveguides , 2010 .

[2]  M. Maharbiz,et al.  Fabrication and testing of a large area, high density, parylene MEMS µECoG array , 2011, 2011 IEEE 24th International Conference on Micro Electro Mechanical Systems.

[3]  Sang-Mo Koo,et al.  Precise Alignment of Single Nanowires and Fabrication of Nanoelectromechanical Switch and Other Test Structures , 2007, IEEE Transactions on Nanotechnology.

[4]  Qiyin Fang,et al.  CMOS Image Sensors for High Speed Applications , 2009, Sensors.

[5]  Bijan Shirinzadeh,et al.  Nanorobot for treatment of patients with artery occlusion , 2006 .

[6]  Qiyin Fang,et al.  Toward a Miniaturized Wireless Fluorescence-Based Diagnostic Imaging System , 2008, IEEE Journal of Selected Topics in Quantum Electronics.

[7]  Ryutaro Maeda,et al.  Transmission Electron Microscope Observations of Si/Si Interface Bonded at Room Temperature by Ar Beam Surface Activation , 1999 .

[8]  Thomas Stieglitz,et al.  “Microflex”—A New Assembling Technique for Interconnects , 2000 .

[9]  Matiar M. R. Howlader,et al.  Nanobonding for Multi-Junction Solar Cells at Room Temperature , 2011 .

[10]  Roger Fabian W. Pease,et al.  Semiconductor crystal islands for three-dimensional integration , 2010 .

[11]  T. Kuiken,et al.  Occupational therapy protocol for amputees with targeted muscle reinnervation. , 2009, Journal of rehabilitation research and development.

[12]  Byoung Hun Lee,et al.  Gate stack technology for nanoscale devices , 2006 .

[13]  D.M.G. Preethichandra,et al.  Nano-Biosensor Development for Biomedical and Environmental Measurements , 2011 .

[14]  J. McDevitt,et al.  Programmable nano-bio-chip sensors: analytical meets clinical. , 2010, Analytical chemistry.

[15]  S. Thompson,et al.  Moore's law: the future of Si microelectronics , 2006 .

[16]  Christoph E. Nebel,et al.  Vertically aligned diamond nanowires: applications a, Fabrication, characterization, and application for DNA sensing , 2009 .

[17]  R. Stein,et al.  Reanimating limbs after injury or disease , 2005, Trends in Neurosciences.

[18]  Tadatomo Suga,et al.  Surface activated bonding of copper through silicon vias and gold stud bumps at room temperature , 2011 .

[19]  S. Ozawa,et al.  Low temperature bonded Cu/LCP materials for FPCs and their characteristics , 2005, IEEE Transactions on Components and Packaging Technologies.

[20]  L.J. Guo Nanoimprint technology and its applications , 2007, 2007 International Workshop on Physics of Semiconductor Devices.

[21]  Philip R. Troyk,et al.  Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording , 2009, IEEE Transactions on Biomedical Engineering.

[22]  Y. Yoshimura,et al.  Through-Silicon via Interconnection for 3D Integration Using Room-Temperature Bonding , 2009, IEEE Transactions on Advanced Packaging.

[23]  Dennis J. McFarland,et al.  Brain–computer interfaces for communication and control , 2002, Clinical Neurophysiology.

[24]  Ib Chorkendorff,et al.  Note: Anodic bonding with cooling of heat-sensitive areas. , 2010, The Review of scientific instruments.

[25]  P. Rolfe,et al.  Medical and biological measurement with micro- and nanosensors , 2010 .

[26]  Tadatomo Suga,et al.  Surface activation-based nanobonding and interconnection at room temperature , 2011 .

[27]  Bertrand Fontaine,et al.  Fitting Neuron Models to Spike Trains , 2011, Front. Neurosci..

[28]  J. Patel,et al.  Copper electroplating to fill blind vias for three-dimensional integration , 2006 .

[29]  Tadatomo Suga,et al.  Investigation of the bonding strength and interface current of p-Si/n-GaAs wafers bonded by surface activated bonding at room temperature , 2001 .

[30]  Wolfgang J. Parak,et al.  Corrosion Protection and Long‐Term Chemical Functionalization of Gallium Arsenide in an Aqueous Environment , 2002 .

[31]  Lei Fu,et al.  Fabrication and characterization of molecular scale field-effect transistors , 2010 .

[32]  T. Suga,et al.  Enhanced Cu/LCP adhesion by pre-sputter cleaning prior to Cu deposition , 2005, IEEE Transactions on Advanced Packaging.

[33]  Tadatomo Suga,et al.  Surface activated bonding of LCP/Cu for electronic packaging , 2005 .

[34]  J. A. Wilson,et al.  Two-dimensional movement control using electrocorticographic signals in humans , 2008, Journal of neural engineering.

[35]  X. Zhao,et al.  Immobilizing catalysts on porous materials , 2006 .

[36]  Paolo Maria Rossini,et al.  Neuroplasticity in amputees: Main implications on bidirectional interfacing of cybernetic hand prostheses , 2009, Progress in Neurobiology.

[37]  Jurriaan Huskens,et al.  Patterned Self‐Assembled Monolayers on Silicon Oxide Prepared by Nanoimprint Lithography and Their Applications in Nanofabrication , 2005 .

[38]  T. Kuiken,et al.  Neural Interfaces for Control of Upper Limb Prostheses: The State of the Art and Future Possibilities , 2011, PM & R : the journal of injury, function, and rehabilitation.

[39]  Jeffrey I. Zink,et al.  Multifunctional inorganic nanoparticles for imaging, targeting, and drug delivery , 2010, BiOS.

[40]  Charles M. Lieber,et al.  Nanoelectronics from the bottom up. , 2007, Nature materials.

[41]  Sang-Gook Kim,et al.  A structured approach to integrate MEMS and Precision Engineering methods , 2010 .

[42]  Martin T. Hill,et al.  A top-down approach to fabrication of high quality vertical heterostructure nanowire arrays. , 2011, Nano letters.

[43]  Thomas D. Wang,et al.  Optical biopsy: a new frontier in endoscopic detection and diagnosis. , 2004, Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association.

[44]  Christoph E. Nebel,et al.  Vertically aligned diamond nanowires: Fabrication, characterization, and application for DNA sensing , 2009 .

[45]  Gerwin Schalk,et al.  Rapid Communication with a “P300” Matrix Speller Using Electrocorticographic Signals (ECoG) , 2010, Front. Neurosci..

[46]  C. S. Tan Accelerated Publication: Thermal characteristic of Cu-Cu bonding layer in 3-D integrated circuits stack , 2010 .

[47]  John E. Bowers,et al.  Heterogeneous integration of silicon and AlGaInAs for a silicon evanescent laser , 2006, SPIE OPTO.

[48]  Michael S. Goldberg,et al.  Nanostructured materials for applications in drug delivery and tissue engineering , 2007, Journal of biomaterials science. Polymer edition.

[49]  Kamlakar P Rajurkar,et al.  NSF-EC workshop on nanomanufacturing and processing: a summary report , 2002, SPIE Micro + Nano Materials, Devices, and Applications.

[50]  Ian Papautsky,et al.  Polymer flip-chip bonding of pressure sensors on flexible Kapton film for neonatal catheters , 2004 .

[51]  Monty Liong,et al.  Multifunctional inorganic nanoparticles for imaging, targeting, and drug delivery. , 2008, ACS nano.

[52]  Paul P Breen,et al.  BION microstimulators: a case study in the engineering of an electronic implantable medical device. , 2011, Medical engineering & physics.

[53]  M Jamal Deen,et al.  Nanobonding Technology Toward Electronic, Fluidic, and Photonic Systems Integration , 2011, IEEE Journal of Selected Topics in Quantum Electronics.

[54]  J. Wolpaw,et al.  Decoding flexion of individual fingers using electrocorticographic signals in humans , 2009, Journal of neural engineering.

[55]  J. W. Meredith,et al.  Microelectronics reliability , 1988, IEEE Region 5 Conference, 1988: 'Spanning the Peaks of Electrotechnology'.

[56]  R. Soref,et al.  Si/Ge junctions formed by nanomembrane bonding. , 2011, ACS nano.

[57]  Tadatomo Suga,et al.  Interfacial Behavior of Surface Activated p-GaP/n-GaAs Bonded Wafers at Room Temperature , 2010 .

[58]  F Cincotti,et al.  Current trends in hardware and software for brain–computer interfaces (BCIs) , 2011, Journal of neural engineering.

[59]  E. T. Rickey Eeg Instrumentation and Technology , 1976 .

[60]  Matiar M. R. Howlader,et al.  Void-free strong bonding of surface activated silicon wafers from room temperature to annealing at 600 °C , 2010 .

[61]  Eric Eisenbraun,et al.  Sub-0.25 micron silicon via etching for 3D interconnects , 2007 .

[62]  G. R. Muller,et al.  Brain oscillations control hand orthosis in a tetraplegic , 2000, Neuroscience Letters.

[63]  Jinn P. Chu,et al.  Interfacial reaction and electrical characteristics of Cu(RuTaNx) on GaAs: Annealing effects , 2011 .