Iterative reconstruction for dual energy CT with an average image-induced nonlocal means regularization

Reducing radiation dose in dual energy computed tomography (DECT) is highly desirable but it may lead to excessive noise in the filtered backprojection (FBP) reconstructed DECT images, which can inevitably increase the diagnostic uncertainty. To obtain clinically acceptable DECT images from low-mAs acquisitions, in this work we develop a novel scheme based on measurement of DECT data. In this scheme, inspired by the success of edge-preserving non-local means (NLM) filtering in CT imaging and the intrinsic characteristics underlying DECT images, i.e. global correlation and non-local similarity, an averaged image induced NLM-based (aviNLM) regularization is incorporated into the penalized weighted least-squares (PWLS) framework. Specifically, the presented NLM-based regularization is designed by averaging the acquired DECT images, which takes the image similarity within the two energies into consideration. In addition, the weighted least-squares term takes into account DECT data-dependent variance. For simplicity, the presented scheme was termed as 'PWLS-aviNLM'. The performance of the presented PWLS-aviNLM algorithm was validated and evaluated on digital phantom, physical phantom and patient data. The extensive experiments validated that the presented PWLS-aviNLM algorithm outperforms the FBP, PWLS-TV and PWLS-NLM algorithms quantitatively. More importantly, it delivers the best qualitative results with the finest details and the fewest noise-induced artifacts, due to the aviNLM regularization learned from DECT images. This study demonstrated the feasibility and efficacy of the presented PWLS-aviNLM algorithm to improve the DECT reconstruction and resulting material decomposition.

[1]  Jing Wang,et al.  Statistical image reconstruction for low-dose CT using nonlocal means-based regularization , 2014, Comput. Medical Imaging Graph..

[2]  Jing Huang,et al.  Penalized weighted least-squares approach for multienergy computed tomography image reconstruction via structure tensor total variation regularization , 2016, Comput. Medical Imaging Graph..

[3]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[4]  Sabee Molloi,et al.  Least squares parameter estimation methods for material decomposition with energy discriminating detectors. , 2010, Medical physics.

[5]  Zhengrong Liang,et al.  Iterative image reconstruction for cerebral perfusion CT using a pre-contrast scan induced edge-preserving prior , 2012, Physics in medicine and biology.

[6]  Darin P Clark,et al.  Spectral diffusion: an algorithm for robust material decomposition of spectral CT data , 2014, Physics in medicine and biology.

[7]  Predrag Sukovic,et al.  Penalized weighted least-squares image reconstruction for dual energy X-ray transmission tomography , 2000, IEEE Transactions on Medical Imaging.

[8]  Ken D. Sauer,et al.  A generalized Gaussian image model for edge-preserving MAP estimation , 1993, IEEE Trans. Image Process..

[9]  Jing Wang,et al.  Deriving adaptive MRF coefficients from previous normal-dose CT scan for low-dose image reconstruction via penalized weighted least-squares minimization. , 2014, Medical physics.

[10]  L Zhu,et al.  TU-F-18A-02: Iterative Image-Domain Decomposition for Dual-Energy CT. , 2014, Medical physics.

[11]  Jing Huang,et al.  Spectral CT Image Restoration via an Average Image-Induced Nonlocal Means Filter , 2016, IEEE Transactions on Biomedical Engineering.

[12]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[13]  Ge Wang,et al.  Spectral CT Reconstruction With Image Sparsity and Spectral Mean , 2016, IEEE Transactions on Computational Imaging.

[14]  James T Dobbins,et al.  Quantitative , 2020, Psychology through Critical Auto-Ethnography.

[15]  Jeffrey A. Fessler,et al.  Statistical Sinogram Restoration in Dual-Energy CT for PET Attenuation Correction , 2009, IEEE Transactions on Medical Imaging.

[16]  Zhicong Yu,et al.  Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography , 2016, Physics in medicine and biology.

[17]  Wufan Chen,et al.  Variance analysis of x-ray CT sinograms in the presence of electronic noise background. , 2012, Medical physics.

[18]  Ken D. Sauer,et al.  Model-Based Iterative Reconstruction for Dual-Energy X-Ray CT Using a Joint Quadratic Likelihood Model , 2014, IEEE Transactions on Medical Imaging.

[19]  David Zhang,et al.  FSIM: A Feature Similarity Index for Image Quality Assessment , 2011, IEEE Transactions on Image Processing.

[20]  C. Mistretta,et al.  Noise reduction in spectral CT: reducing dose and breaking the trade-off between image noise and energy bin selection. , 2011, Medical physics.

[21]  Barry J. Sullivan,et al.  A generalized Landweber iteration for ill-conditioned signal restoration , 1991, [Proceedings] ICASSP 91: 1991 International Conference on Acoustics, Speech, and Signal Processing.

[22]  Xiaoqun Zhang,et al.  TICMR: Total Image Constrained Material Reconstruction via Nonlocal Total Variation Regularization for Spectral CT , 2016, IEEE Transactions on Medical Imaging.

[23]  Ehsan Samei,et al.  Towards task-based assessment of CT performance: System and object MTF across different reconstruction algorithms. , 2012, Medical physics.

[24]  Jing Huang,et al.  Iterative Reconstruction for X-Ray Computed Tomography Using Prior-Image Induced Nonlocal Regularization , 2014, IEEE Transactions on Biomedical Engineering.

[25]  U. Schoepf,et al.  Comparison of dual-energy computed tomography of the heart with single photon emission computed tomography for assessment of coronary artery stenosis and of the myocardial blood supply. , 2009, The American journal of cardiology.

[26]  Lei Zhu,et al.  Iterative image-domain decomposition for dual-energy CT. , 2014, Medical physics.

[27]  Jianhua Ma,et al.  Extracting Information From Previous Full-Dose CT Scan for Knowledge-Based Bayesian Reconstruction of Current Low-Dose CT Images , 2016, IEEE Transactions on Medical Imaging.

[28]  Zhengrong Liang,et al.  Variance analysis of x-ray CT sinograms in the presence of electronic noise background. , 2012, Medical physics.

[29]  Jing Wang,et al.  Simultaneous 4D-CBCT reconstruction with sliding motion constraint. , 2016, Medical physics.

[30]  Polad M Shikhaliev,et al.  Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study , 2005, Physics in medicine and biology.

[31]  M. Reiser,et al.  Material differentiation by dual energy CT: initial experience , 2007, European Radiology.

[32]  T. Flohr,et al.  Spectral Computed Tomography , 2012 .

[33]  Jean-Michel Morel,et al.  A Review of Image Denoising Algorithms, with a New One , 2005, Multiscale Model. Simul..

[34]  Zhaoying Bian,et al.  Cerebral perfusion computed tomography deconvolution via structure tensor total variation regularization. , 2016, Medical physics.

[35]  Jeffrey A. Fessler,et al.  Multi-Material Decomposition Using Statistical Image Reconstruction for Spectral CT , 2014, IEEE Transactions on Medical Imaging.

[36]  W. Kalender,et al.  An algorithm for noise suppression in dual energy CT material density images. , 1988, IEEE transactions on medical imaging.

[37]  Zhaoying Bian,et al.  A Simple Low-Dose X-Ray CT Simulation From High-Dose Scan , 2015, IEEE Transactions on Nuclear Science.

[38]  J Nuyts,et al.  Iterative image reconstruction methods , 2005 .

[39]  Lei Zhu,et al.  Noise Suppression for Dual-Energy CT Through Entropy Minimization , 2015, IEEE Transactions on Medical Imaging.

[40]  Qi Wang,et al.  Noise Reduction in Stereo Disparity Images based on Spectral Analysis , 2009 .

[41]  Tsuhan Chen,et al.  Robust Low-Dose CT Perfusion Deconvolution via Tensor Total-Variation Regularization , 2015, IEEE Transactions on Medical Imaging.

[42]  R. A. Rutherford,et al.  Measurement of effective atomic number and electron density using an EMI scanner , 2004, Neuroradiology.

[43]  田中功,et al.  新しいModel‐Based Iterative Reconstructionにおける再構成パラメーター(Recon Setting)に関する検討 , 2017 .

[44]  Lei Zhu,et al.  Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization. , 2014, Medical physics.

[45]  Guang-Hong Chen,et al.  Dual energy CT using slow kVp switching acquisition and prior image constrained compressed sensing , 2010, Physics in medicine and biology.