A voltage input-based magnetic equivalent circuit model for wound rotor synchronous machines

A mesh-based dynamic magnetic equivalent circuit model for wound rotor synchronous machines has been derived in this research. As part of this effort, a reluctance network has been enhanced to model flux distribution around stator tooth tips and damper bar openings. Faraday's law is applied to establish a state model in which stator winding flux linkages are selected as state variables. The resulting coupled MEC/state model is solved to analyze machine dynamics.

[1]  Xavier Jannot,et al.  Optimization of Wound Rotor Synchronous Generators Based on Genetic Algorithms , 2011, Computational Methods for the Innovative Design of Electrical Devices.

[2]  Ivan Mandić,et al.  Optimization of large electrical salient pole synchronous generators , 2001 .

[3]  Wan Shuting,et al.  Reluctance network model of turbo-generator and its application - part 1: model , 2005, 2005 International Conference on Electrical Machines and Systems.

[4]  J. Jatskevich,et al.  Reduced-Order Modeling of High-Fidelity Magnetic Equivalent Circuits , 2009, IEEE Transactions on Power Electronics.

[5]  J. Jatskevich,et al.  Reduced-Order Dynamic Modeling of Multiple-Winding Power Electronic Magnetic Components , 2012, IEEE Transactions on Power Electronics.

[6]  Grant M Shane,et al.  Refinements in Anhysteretic Characterization and Permeability Modeling , 2010, IEEE Transactions on Magnetics.

[7]  D. C. Macdonald,et al.  Circuit Representation of Inverter-Fed Synchronous Motors , 1989, IEEE Power Engineering Review.

[8]  K. Abbaszadeh,et al.  Modeling and simulation of turn-fault and unbalance magnetic pull in induction motor based on magnetic equivalent circuit method , 2005, 2005 International Conference on Electrical Machines and Systems.

[9]  M L Bash,et al.  Modeling of Salient-Pole Wound-Rotor Synchronous Machines for Population-Based Design , 2011, IEEE Transactions on Energy Conversion.

[10]  E. Schlemmer,et al.  Application of stochastic simulation in the optimisation process of hydroelectric generators , 2003 .

[11]  V. Ostovic A novel method for evaluation of transient states in saturated electric machines , 1989 .

[12]  Marco Amrhein,et al.  Induction Machine Performance Improvements: Design-Oriented Approaches , 2007 .

[13]  Joshua M Williams,et al.  Incorporating Motion in Mesh-Based Magnetic Equivalent Circuits , 2010, IEEE Transactions on Energy Conversion.

[14]  Gordon R. Slemon,et al.  Implementation of an equivalent circuit approach to the analysis of synchronous machines , 1994 .

[15]  Gordon R. Slemon An equivalent circuit approach to analysis of synchronous machines with saliency and saturation , 1990 .

[16]  S. Pekarek,et al.  Analysis and Validation of a Population-Based Design of a Wound-Rotor Synchronous Machine , 2012, IEEE Transactions on Energy Conversion.

[17]  M. Celebi Weight optimisation of a salient pole synchronous generator by a new genetic algorithm validated by finite element analysis , 2009 .

[18]  N.A.O. Demerdash,et al.  Analysis and Diagnostics of Adjacent and Nonadjacent Broken-Rotor-Bar Faults in Squirrel-Cage Induction Machines , 2009, IEEE Transactions on Industrial Electronics.

[19]  David C. Hamill,et al.  Lumped equivalent circuits of magnetic components: the gyrator-capacitor approach , 1993 .

[20]  A.C. Koenig,et al.  A Comparison of Nodal- and Mesh-Based Magnetic Equivalent Circuit Models , 2009, IEEE Transactions on Energy Conversion.

[21]  K. J. Bradley,et al.  Reluctance mesh modelling of induction motors with healthy and faulty rotors , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[22]  P.T. Krein,et al.  Magnetic Equivalent Circuit Modeling of Induction Machines Design-Oriented Approach with Extension to 3-D , 2007, 2007 IEEE International Electric Machines & Drives Conference.