Parallel Operation of Three-Phase Bi-Directional Isolated Interleaved DC-DC Converters for The Battery Charge/Discharge System

Recently, parallel operation of dc-dc converters has been widely used in distributed power systems. In this paper, a control method to achieve parallel operation of three-phase bi-directional isolated interleaved dc-dc converters is discussed for the battery charging and discharging system which consists of the 32 battery charger/dischargers and two three-phase bi-directional isolated interleaved dc-dc converters. In the boost mode, the battery energy is delivered to the grid, whereas the grid energy is transferred to the battery in the buck mode operation. The average current sharing control method is employed to obtain an equal conducting of each phase current in the three-phase dc-dc converter. By using the proposed method, the imbalance factor is gratefully reduced from 8 percent to 1 percent. Two 2.5kW three-phase bi-directional dc-dc converter prototype have been built and the proposed method has been verified through experiments.

[1]  Caisheng Wang,et al.  Analysis of Inductor Current Sharing in Nonisolated and Isolated Multiphase dc–dc Converters , 2007, IEEE Transactions on Industrial Electronics.

[2]  E.K.K. Sng,et al.  A novel communication strategy for decentralized control of paralleled multi-inverter systems , 2006, IEEE Transactions on Power Electronics.

[3]  I. Barbi,et al.  A Three-Phase Current-Fed Push–Pull DC–DC Converter , 2009, IEEE Transactions on Power Electronics.

[4]  Dehong Xu,et al.  Modeling, analysis, and implementation of parallel multi-inverter systems with instantaneous average-current-sharing scheme , 2003 .

[5]  S.J. Chiang,et al.  Current limitation control technique for parallel operation of UPS inverters , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[6]  Yim-Shu Lee,et al.  Design and analysis of an optimal controller for parallel multi-inverter systems , 2006, IEEE Transactions on Circuits and Systems II: Express Briefs.

[7]  Hirofumi Akagi,et al.  A 6-kW, 2-kWh Lithium-Ion battery energy storage system using a bidirectional isolated DC-DC converter , 2010, The 2010 International Power Electronics Conference - ECCE ASIA -.

[8]  Milan M. Jovanovic,et al.  Loop gain measurement of paralleled dc-dc converters with average-current-sharing control , 2008 .

[9]  K H Ahmed,et al.  Improved Instantaneous Average Current-Sharing Control Scheme for Parallel-Connected Inverter Considering Line Impedance Impact in Microgrid Networks , 2011, IEEE Transactions on Power Electronics.

[10]  Byung-Moon Han,et al.  A Three-Phase Interleaved DC–DC Converter With Active Clamp for Fuel Cells , 2010, IEEE Transactions on Power Electronics.

[11]  Jaeho Choi,et al.  Droop Control for Parallel Inverers in Islanded Microgrid Considering Unbalanced Low-Voltage Line Impedances , 2013 .

[12]  Jun-Young Lee,et al.  Digital Load Sharing Method for Converter parallel Operation , 2012 .

[13]  J. Allen Byrne An update on the codes, standards and guides applicable to stationary lead-acid batteries , 2010, Intelec 2010.

[14]  Bo-Hyung Cho,et al.  A novel droop method for converter parallel operation , 2002 .

[15]  Vladimir Blasko,et al.  A New Bi-directional Three-phase Interleaved Isolated Converter with Active Clamp , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.