Effect of hinge gap width on the microflow structures in 27-mm bileaflet mechanical heart valves.
暂无分享,去创建一个
Ajit P Yoganathan | Hélène A. Simon | Lakshmi P Dasi | A. Yoganathan | L. Dasi | H. Leo | Hwa-Liang Leo | Hélène A Simon
[1] A P Yoganathan,et al. A microstructural flow analysis within a bileaflet mechanical heart valve hinge. , 1996, The Journal of heart valve disease.
[2] Joseph D. Bronzino,et al. The Biomedical Engineering Handbook , 1995 .
[3] Brandon R. Travis,et al. An In Vitro Study of the Hinge and Near-Field Forward Flow Dynamics of the St. Jude Medical® Regent™ Bileaflet Mechanical Heart Valve , 2004, Annals of Biomedical Engineering.
[4] R M Hochmuth,et al. Shear-induced aggregation and lysis of platelets. , 1976, Transactions - American Society for Artificial Internal Organs.
[5] A P Yoganathan,et al. Velocity measurements and flow patterns within the hinge region of a Medtronic Parallel bileaflet mechanical valve with clear housing. , 1996, The Journal of heart valve disease.
[6] L Zuckerman,et al. Shear-induced activation of platelets. , 1979, Journal of biomechanics.
[7] N H Hwang,et al. Human red blood cell hemolysis in a turbulent shear flow: contribution of Reynolds shear stresses. , 1984, Biorheology.
[8] Jeffrey Thomas Ellis. An in vitro investigation of the leakage and hinge flow fields through bileaflet mechanical heart valves and their relevance to thrombogenesis , 1999 .
[9] Ajit P Yoganathan,et al. Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve design. , 2002, The Journal of thoracic and cardiovascular surgery.
[10] Hwa Liang Leo,et al. Bileaflet Aortic Valve Prosthesis Pivot Geometry Influences Platelet Secretion and Anionic Phospholipid Exposure , 2001, Annals of Biomedical Engineering.
[11] P. J. Drury,et al. Mechanical and other problems of artificial valves. , 1994, Current topics in pathology. Ergebnisse der Pathologie.
[12] H Reul,et al. Leakage flow at mechanical heart valve prostheses: improved washout or increased blood damage? , 1999, The Journal of heart valve disease.
[13] Brandon Travis. The effects of bileaflet prosthesis pivot geometry on turbulence and blood damage potential , 2001 .
[14] A P Yoganathan,et al. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves. , 1996, The Journal of heart valve disease.
[15] Helene A. Simon. Influence of the Implant Location on the Hinge and Leakage Flow Fields Through Bileaflet Mechanical Heart Valves , 2004 .
[16] F. R. Rosendaal,et al. Thromboembolic and Bleeding Complications in Patients With Mechanical Heart Valve Prostheses , 1994, Circulation.
[17] Ajit P. Yoganathan. Cardiac Valve Prostheses , 1999 .
[18] A P Yoganathan,et al. A comparison of the hinge and near-hinge flow fields of the St Jude medical hemodynamic plus and regent bileaflet mechanical heart valves. , 2000, The Journal of thoracic and cardiovascular surgery.
[19] P. Lu,et al. A reevaluation and discussion on the threshold limit for hemolysis in a turbulent shear flow. , 2001, Journal of biomechanics.
[20] H. Leo. An in vitro investigation of the flow fields through bileaflet and polymeric prosthetic heart valves. , 2005 .
[21] Richard A. Lange,et al. Prosthetic heart valves. , 1996, The New England journal of medicine.