Pumping gases by a silicon micro pump with dynamic passive valves
暂无分享,去创建一个
Pumping gases by a membrane pump requires a strong compression ratio inside the pump chamber. This demand is fulfilled by an optimized micro pump with dynamic passive valves, working at the resonance frequency. The experimental results for the zero-load pump rate and the maximum pump pressure are 7.5 ml/min and 2.8 kPa, respectively. The pump's behaviour is described by a mathematical model. The calculated values coincide with the experimental data quite well.
[1] Torsten Gerlach. Microdiffusers as dynamic passive valves for micropump applications , 1998 .
[2] Torsten Gerlach,et al. Working principle and performance of the dynamic micropump , 1995 .
[3] Albert van den Berg,et al. A silicon integrated miniature chemical analysis system , 1992 .
[4] Werner Karl Schomburg,et al. LIGA micropump for gases and liquids , 1994 .