A Hybrid Constrained State Estimator with Pseudo Injection Measurements

The proposed hybrid state estimator calculates pseudo-injections from the voltage and current phasors collected by Phasor Measurement Units (PMUs). The pseudo-injections are combined with the voltage phasors and conventional measurements as inputs for the iterative algorithm with addition of equality constraints for zero-injections. The methodology is tested on the IEEE test systems with 14, 30, 57 and 118 buses as well as on the Croatian transmission power system and compared to the classical solution that uses conventional measurements only. Streszczenie. Zaproponowano hybrydowy estymator stanu obliczający pseudo-injekcje z napiecia i prądu fazora. Metode przetestowano w systemie IEEE z rozną liczbą szyn a takze w chorwackim systemie energetycznym. (Hybrydowy wymuszony estymator stanu wz pomiarem pseudo- injekcji)

[1]  Vedran Kirincic,et al.  Croatian Academic Research Wide Area Monitoring System - CARWAMS , 2011 .

[2]  S. Chakrabarti,et al.  A Constrained Formulation for Hybrid State Estimation , 2011, IEEE Transactions on Power Systems.

[3]  B. Taylor,et al.  Status Report on the ISO/IEC/OIML/BIPM Guide, Expression of Uncertainty in Measurement , 1992 .

[4]  A. G. Expósito,et al.  Power system state estimation : theory and implementation , 2004 .

[5]  A. Monti,et al.  Distributed intelligence for smart grid control , 2010, 2010 International School on Nonsinusoidal Currents and Compensation.

[6]  Vladimir Terzija,et al.  State estimation including synchronized measurements , 2009, 2009 IEEE Bucharest PowerTech.

[7]  A. Monticelli,et al.  Electric power system state estimation , 2000, Proceedings of the IEEE.

[8]  Ivica Pavić,et al.  Power system state estimation based on PMU measurements vs SCADA measurements , 2012 .

[9]  T. Okon,et al.  Weighted-Least-Squares power system state estimation in different coordinate systems , 2010 .

[10]  Mohammad Reza Mosavi,et al.  A PMU Placement Optimal Method in Power Systems using Modified ACO Algorithm and GPS Timing , 2012 .

[11]  M. Gilles,et al.  A blocked sparse matrix formulation for the solution of equality-constrained state estimation , 1991, IEEE Power Engineering Review.

[12]  A. Monticelli State estimation in electric power systems : a generalized approach , 1999 .

[13]  Vedran Kirincic,et al.  DYNAMIC ANALYSIS OF WIND FARM OPERATION INTEGRATED IN POWER SYSTEM BASED ON SYNCHRONIZED MEASUREMENTS , 2010 .

[14]  Tianshu Bi,et al.  A novel hybrid state estimator for including synchronized phasor measurements , 2008 .

[15]  A.G. Phadke,et al.  Hybrid Linear State Estimation Utilizing Synchronized Phasor Measurements , 2007, 2007 IEEE Lausanne Power Tech.

[16]  Srdjan Skok,et al.  Enhanced open architecture of phasor data concentrator , 2011 .